Top 20 DeLonghi DE500 Dehumidifier - Page 3 Questions & Answers

0helpful
1answer

Can a Delonghi dehumidifier DH25 be connected to an outlet pipe to get rid of the water? It's working fine, but I ned to empty it nearly every day

Some dehumidifiers have provisions for connection of an ordinary garden hose to drain into a tub, a standpipe, or a sump pit.
12/28/2020 9:08:21 AM • DeLonghi... • 101 views • 0 helpful votes
0helpful
1answer

I would like to have the delonghi de400p drain from front hose instead of into bucket

all this info is in the manual. Either you threw it away or are a person who does not like to read.
9/19/2019 4:33:10 PM • DeLonghi... • 200 views • 0 helpful votes
0helpful
1answer

De longhi dehumidifier showing yellow light

Usually happens when the float valve is stuck in the down or up position try wiggling the handle to release or if the collection bucket is not sitting perfectly on the safety switch has to be down square I have the delonghi dem10 model always empty and unplug before checking
1/31/2019 4:32:21 PM • DeLonghi... • 1,033 views • 0 helpful votes
0helpful
1answer

Your DeLonghi DE500P cannot condense wet air into water, although it forms icy blocks which blocks the flow of water.

Dear Heemin, From the wording which you have used, it appears you think you are talking to the DeLonghi company. You are not. You are speaking to "fixya:". Please contact DeLonghi or one of it's dealers by finding their access information on your computer's search engine. God bless your efforts.
7/5/2018 7:38:31 PM • DeLonghi... • 299 views • 0 helpful votes
0helpful
1answer

Where can I get instructions for a DeLonghi dehumidifier model DDe 50e?

Free online manual: https://www.manualslib.com/manual/228038/Delonghi-Dde40e.html#product-DDE%2050E Delonghi DDE40E Use And Maintenance Manualhttps://www.manualslib.com/manual/254660/Delonghi-40eddh30.html#product-DDE%2050E
4/19/2018 5:40:34 PM • DeLonghi... • 436 views • 0 helpful votes
0helpful
1answer

Good morning. I have a DeLonghi

Are you worried as to why there is no Water in the Water Tank/Bucket at all? Well, a few operational basics must be understood by you please. For the unit to remove moisture from the air and draw water into the bucket/tank, the set relative humidity (%RH) must be below the current or ambient room relative humidity. Attempt to lower or reduce the setting you have to a lower value and it should start collecting water in the tank. Hope this helps
11/14/2017 10:09:03 AM • DeLonghi... • 548 views • 0 helpful votes
0helpful
1answer
0helpful
1answer

Delonghi dehumidifier is not drawing in liquid, have run it all night but nothing and there is still mist on windows, can you please advise

It's basically an air conditioner so if the fan is running---the condenser not plugged up via rats nest---lint----the float switch working---if possible tip over switch working----the system maybe low on refrigerant
5/31/2017 12:45:08 AM • DeLonghi... • 476 views • 0 helpful votes
0helpful
1answer

Dh25 the cooling coils get frozen,the appliance sill working even the canister is full.

The normal operating temperature is above 65 F. Much below unless specially designed for low temperature they will freeze up. They have a frost detector and will defrost but it is very inefficient and not practical. My experience they eventually form a block of ice on the coils. They heat the room in the process so in a moderate area they can raise the temperature and provide needed circulation. In the past where the temperature is cool I have faced the output into a corner, raised it off the floor and once the unit got started the heat created from the unit kept the air warm enough to avoid freezing up the coils. Always check for recalls. Some models have had problems and have been recalled. See the link below. 26051775-3tozjaopshvuyndb2zxhmboi-4-0.jpg Gree Reannounces Dehumidifier Recall Due to Serious Fire and Burn Hazards... Hope this has helped? 26051775-3tozjaopshvuyndb2zxhmboi-4-2.jpg
1/13/2016 10:47:04 AM • DeLonghi... • 277 views • 0 helpful votes
1helpful
1answer

DeLonghi DD70PE Dehumidifier. Why does pump often stop working and F/P shows an error code until reset?

id be inclined to think that for some reason the pump is taking too long to pump tank out (or it thinks it is ) this would cause the fault you describe and the safety control shuts pump off for fear of a problem
8/18/2015 7:55:43 PM • DeLonghi... • 837 views • 1 helpful votes
1helpful
1answer

My unit, I don't know which one, seems to have a short circuit; it blows fuses.

if your unit is old enough to "not" have a gfci on the plug that goes in wall then im not aware it has any fuse inside it that could go bad , instead these rely on the homes proper electrical ckts to provide fuse/breaker functions that keep a fire from resulting if appliance overloads , now as for reasons of overloads these are many ! can be anything from water in the wrong place to a damaged motor inside
9/23/2015 10:58:12 PM • DeLonghi... • 228 views • 1 helpful votes
1helpful
1answer

Whats the weight of delonghi de120 dehumidifier

18 kg or 39.6 lbs
3/3/2015 5:46:01 PM • DeLonghi... • 82 views • 1 helpful votes
1helpful
1answer

How do I replace the frost guard switch

The frost guard switch is usually attached to one of the copper tubes on or near the evaporator by a little spring type clip. Without a model number I cannot look up a diagram, but you could google it. Most of the self contained freeze switch units that I have run into require them to get quite warm like 90 degrees F before they will reset themselves. Try a hair dryer on it to reset before buying a new one
1/27/2015 1:22:59 PM • DeLonghi... • 118 views • 1 helpful votes
0helpful
1answer
0helpful
1answer

Why ismy dehumidifier leaking water from underneath unit what to do?

You either have a loose hose or the sensor that lets it know it is full is not working and the catch bucket is over flowing.
9/4/2014 1:29:38 AM • DeLonghi... • 264 views • 0 helpful votes
1helpful
1answer

Can it be used in toilet ? The walls are damp due to basement

It can be used in a bathroom in a safe place. It might taut of the bowel and drain traps but should not take any water out of the tank an air conditioner is a big humidifier so if you have an A/C you already have some moister being taken out. And a heating unit takes even more out then the A/C so I would say no problem.
8/28/2014 7:57:00 PM • DeLonghi... • 78 views • 1 helpful votes
0helpful
1answer

What causes a dehumidifier to leak?

The automatic shutoff might be defective or the leak comes from the water reservoir.
6/11/2014 6:27:24 PM • DeLonghi... • 394 views • 0 helpful votes
0helpful
1answer

Delonghi DM10 low temp light flashing continuously.

De Longhi United Kingdom Home Contact delonghi customer support
2/26/2014 7:01:48 PM • DeLonghi... • 700 views • 0 helpful votes
0helpful
1answer

Red light wont go off

Should have bought a Vicks! My red light goes OFF! No it easy. Unplug the unit for 10 minutes. Fill up with water while waiting. Turn it on! If the red light still come on then you gots scale or build up inside that needs to cleaned out. Follow or call manufacture on how to clean unit... If you need further help, reach me via phone at https://www.6ya.com/expert/steven_b77d19396bfe2249
1/19/2014 12:36:08 PM • DeLonghi... • 419 views • 0 helpful votes
Not finding what you are looking for?
DeLonghi DE500 Dehumidifier Logo

Popular Tags

61 questions posted

Ask a Question

Usually answered in minutes!

Top DeLonghi Dehumidifiers Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Cindy Wells

Level 3 Expert

6688 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a DeLonghi Dehumidifier Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

DeLonghi Dehumidifiers

  • DeLonghi Dehumidifiers

Most Popular Question

machine running but no water being

  • Dehumidifiers
Loading...