This is a repair that someone I know didafter reading a post on the net.....regarding Quadra repairs....and here is a link for repairs....its all one link....so type it into your browser or paste it.....

http://www.airpurifierrepair.com/ProductDetails.aspx?ID=34&ProductId=591


Remove the grid assembly.

Remove the 4 screws holding the top on.

Gently remove the top as there are wires connected to it.

Once removed, find the microswitch assembly on the side. There will be 2 green wires going to this assy board (PCB).

Examine the bottom of this board. On both my units, the PCB wascorroded badly on the trace that runs from the center lead to the wireconnection. This will cause the microswitch to quit working.

What I did was soldered a wire from the center contact of themicroswitch (center piece coming through the board. There should be alarge solder pool) to the wire connection at the edge of the board.This just 'goes around' the corroded PCB trace.

Worked fantastic on both ionic breezes and took about 5 minutes for thesecond one. The first one took over 2 hours just to find the problem.

I hope this helps.....good luck...thanks for rating my effort....the Fang.

Sharper Image... | Answered on Jul 14, 2019


Try this site.
I FOUND THIS WEB SITE that I think will help you with this question and a lot more. Since this web site will have access to many different vehicles I hope you do not feel like I am lazy by just passing along the web site instead of giving you the exact information you asked for.



Go to this site to find a manual to help you.
https://www.browsemanuals.co/lander_zrk65_test14.html?t1=1535071160&t2=65192170713&t3=kwd-28425796&gclid=EAIaIQobChMI-oybpN624AIVwdVkCh2GtguWEAEYASAAEgJ9yvD_BwE

Sharper Image... | Answered on Feb 23, 2019


You can replace the fuse by soldering a new one into place -- it's a standard fuse, just match the amp rating of old to new.

Chances are though, after you do this, it will blow again. So, there's a good chance the unit is kaput.

I have extensive experience with these units to the point of even replacing the high-voltage field wires (the two fine wires which run from top to bottom) with titanium wire. There is no real good way to keep these things running properly -- they're kinda like weed whackers -- inherently problematic.

Sharper Image... | Answered on Jul 06, 2018


I tried the guitar strings, they burned out quickly. The wires that came in the unit are not steel, they are not affected by a magnet. We suspect they may be tungsten or some other type of non ferrous wire. Until we find the right wire, we cannot repair them to last. Any assistance in locating the correct type of wire for use in ionizing air cleaners would be appreciated.

Sharper Image... | Answered on Jul 06, 2018

Not finding what you are looking for?
Sharper Image Logo

706 questions posted

Ask a Question

Usually answered in minutes!

Top Sharper Image Air Purifiers Experts

Ekse

Level 3 Expert

13434 Answers

Marvin
Marvin

Level 3 Expert

85161 Answers

Jason

Level 2 Expert

218 Answers

Are you a Sharper Image Air Purifier Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...