Question about Jacuzzi Amiga, Soaking Bathtub with Integral Skirt - T715

2 Answers

Heater pump does not turn on Jacuzzi hot tub 325

Posted by on

Ad

2 Answers

  • Level 1:

    An expert who has achieved level 1.

    Hot-Shot:

    An expert who has answered 20 questions.

    Corporal:

    An expert that has over 10 points.

    Mayor:

    An expert whose answer got voted for 2 times.

  • Contributor
  • 27 Answers

You should be getting error messages like flo or FLO2. check the voltage to the pump from the board if power is there the pump is bad and needs replacing

Posted on Jul 20, 2009

Ad
  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that got 5 achievements.

    Governor:

    An expert whose answer got voted for 20 times.

    Scholar:

    An expert who has written 20 answers of more than 400 characters.

  • Expert
  • 80 Answers

Heater operates seperate from pumps. Do the pumps come on? Pressure/flow switch turns on heater, so if the pumps work, there is an issue with the heater element, the flow switch will usually prevent the spa from running at all and there will be an error code on the control panel.

Posted on Aug 19, 2009

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE:

Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.

Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

Here's a link to this great service

Good luck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

My hot tub will not heat up and the one pump is running. I can not turn the lights on or adjust the controls


check the fuses if no heat sounds like the pump that isnt running is the recirculation pump (which heater is connected to) if fuses keep blowing try disconnecting the heater element maybe shorted

Mar 04, 2015 | Jacuzzi Pool & Spa

1 Answer

Jacuzzi z112


What is the problem you afe having with your Jacuzzi Water Heater?
Is this a Jacuzzi Hot Tub?-- Do you have some indicator lights on?-- what color are the lights?--
Is the Circulating pump running water thru the heater element?
Tell me more!-- Let's walk thru the system, and figure it out-- Mack B

Oct 13, 2013 | Water Heaters

1 Answer

I have a Jacuzzi J340 Hot Tub. I am having trouble with the heating. When the pump is on, the water circulates just fine. once the heater kicks on, it runs for about 10 seconds, then clicks to OH, and...


make sure the heating element isnt touching the casing inside the heating tube. if its an indoor tub, make sure the filtration cycles are not set to constant. constant filter cycles on an indoor tub will generate residual heat from the circ pump running 24/7, causing tub to heat past 104 degrees

Sep 15, 2013 | Jacuzzi Pool & Spa

1 Answer

Jacuzzi hot tub, Water is too hot. Heats until it trips the system. I have replaced the analog temperature control,


1) Safety question first
Why hasn't the GFCI tripped.
If your spa is not protected by ground fault., then you are at serious personal risk.
http://waterheatertimer.org/How-to-wire-GFCI.html#arc-fault

2) Replace the element.
http://waterheatertimer.org/How-to-test-water-heater-element.html

3) If element is cracked, it can continue heating to ground wire, causing runaway heating.
This applies to spas, and water heaters of all type.

If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7

Dec 08, 2012 | Jacuzzi Pool & Spa

1 Answer

Hello,I have an old jacuzzi vectra II hot tub (1988) 120 volt.the gfci on the unit trips every time the pump is on low speed with the thermostat calling for heat. there is no trip when there is no demand...


hi,

ok so when the pump is on high and the heater is running it doesent trip? you didnt say if it did. undo the heater leads so the pump is isolated completely. run the pump on the control centers gfci and see if it trips. if it does then try wiring directly - with an extension cord to a plug with a gfci in your house and see if it trips the gfci in your bathroom. if no trip inside house then bypass tubs gfci and run it with heater and pump through your bathroom gfci. if no trip then try and replace the tubs gfci, it gets pretty humid in the control center and gfci's have a semiconductor which which do fail after years of rough duty like that. if it trips the gfci in your house with the heater again it has a cracked heater element. craigslist always has old hot tubs and parts. you might have to buy a whole used old hot tub but that may be cheaper than a new heater box.

later

jm

Feb 22, 2011 | Jacuzzi MAGNUM FORCE POOL PUMP - TWO SPEED...

2 Answers

One of the jet assemblies on my Jacuzzi 325 hot tub popped out and I can't get it to stay back in. i've been pushing it in as hard as I can but when I turn the pumps on it pops back out. Should I be...


once a jet face has fallen out of a hot tub that means the insert has failed and is broken. you will need to locate a new jet insert. Jet inserts have little tabs on them that hold them in place and when they get worn out the jet face will fall out into the tub.

Jan 29, 2011 | Jacuzzi Home

1 Answer

We have a hot tub or jacuzzi inside or on the side of our pool. We had a new heater installed. The jacuzzi should heat up very quickly but now the pool tech claims the drain from the jacuzzi is blocked,...


Is the equipment to heat and filter the hot tub separate from the pool equipment or do both bodies of water share a common heater and filter pump? In most cases they share a pump and heater with valves that direct the flow of water depending on how the pool owner wants to use the pools.

The first thing you need to determine then is if the equipment is working properly. Is there flow of water to and from the spa? If so, is the heater burner kicking on? If it is running, is it running properly with sufficient gas pressure, 3-4" tall bright blue flames and stays on continuously during the heating cycle for the spa?

What is 'very quickly' for the time to heat the water? In other words, if everything appears to be operating normally but the water is not warming fast enough or at all how much time is elapsing before deciding the heater is not working?

How old is this equipment and how much experience do you have with this pool tech or the company they are from?

Nov 07, 2010 | Jacuzzi Pool & Spa

1 Answer

Rapid Heater for Jacuzzi


The light is supposed to be on when the tub is full of water and the pump comes on. Make sure the heater is plugged into a seperate breaker, it cannot be on the same line as the pump.
Look on the heater for a label. If your heater is installed on the discharge side of the pump it should say "pressure heater" on it. If it is installed in front of the pump it should say "Vacuum Heater" on it.
Once installed, fill the tub with water and turn the pump on. If it is installed in the correct position the light will come on when the pump turns on.

Feb 22, 2009 | Jacuzzi RapidHeat In-Line Heater U395000 [...

1 Answer

Jacuzzi not so cuzzi. Could it be just the heater?


There are usually two breakers for a hot tub. One sends power to the heater and another sends power to the big pump.

Be sure both breakers are turned all the way too off and then turn them to on. Next look for a reset button on inside of the jacuzzi which may have to be reset.

good luck

Jan 21, 2009 | Home

Not finding what you are looking for?
Jacuzzi Amiga, Soaking Bathtub with Integral Skirt - T715 Logo

1,323 people viewed this question

Ask a Question

Usually answered in minutes!

Top Jacuzzi Home Experts

US Parts Center
US Parts Center

Level 3 Expert

719 Answers

Mike

Level 3 Expert

4363 Answers

john h

Level 3 Expert

22408 Answers

Are you a Jacuzzi Home Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...