Frigidaire FAH106N1 Wall/Window Air Conditioner - Page 6 Questions & Answers
Brand-new window unit emits musty smell when compressor shuts off
It SHOULD NOT ... (smell in... even in WEST TEXAS).
BRAND NEW... Rush on down and get a good
NEW one.
I would suspect the condensate drip pan is plugged...
Common for AC units ..
But
NEVER in "
brand new"...
Get that (previously owned (my opinion)) UNIT
back from where you bought it ... Trade it in for a CLOSED BOX... and make your sales CLOWN write up why you are returning it.
Mold can be quite dangerous!!
Carnac the Magnificent
What does E5 means when it shows?
Can't find E5 but ES is a probable faulty evaporator sensor fault. Check the wireing for any damage or loose conections and if all is ok thenyou will have oreplace the sensor. Hope this helps
Frigidaire lra157mt1
Some of the new style Air conditioners have a auto time delay built into them for power failures. If power fails or you unplug the unit, they will not come back on for about 3 to 5 minutes. This is a safety feature to keep power failures from damaging the compressor. Keep it plugged in for 5 minutes and try again. If still no go then call for service. You should have a 1 year warranty on it.
Clean window ac unit
What do you need to know about cleaning your wall unit? If you need any other assistance check us out online at
Boca AC Service we are always happy to lend a helping hand.
I have my brand new frigidaire window ac unit set at 60 degrees Fahrenheit, so why does it only cool and keep the room at 65 to 68 degrees Fahrenheit?
if you have it set at 60 F and it is working at 65 to 68 F then that would be about right
as the air is cooled the cold air falls to the floor and out under the door, open window or anywhere else it can escape
the unit has to be at 80% room height so if it is set in a window then when the cold air gets up to the thermostat or ac level in the window then it will stop cooling
So if the ac unit is say 4ft from the floor and the ceiling height is 8 ft then the ac will only cool the bottom 4 ft
cold air does not rise but falls down
if you are using a ceiling fan then the cold air is stirred up and the 65F sounds about right
remember that the setting temp ( what you set it at) is the lowest temp that it will go down to before it stops cooling and if that is not reached it will keep working to attain that temp and if the room is too big, air leaks under door . around the fit in the window , no insulated walls , hot exterior wall,etc then maybe 65 F is the best you will get