Our unit is only 16 months old and just noticed things in the freezer not solidly frozen. Upper fridge is fine, but freezer not cooling low enough
There is a fan that blows air past the coils in the freezer. Either the fan is not working or the coils are blocked with ice. Sometime ice stops the fan from turning. listen for the fan spinning by turning the thermostat down. Defrost the coils and fan and see if the frig returns to normal. Sometimes the drain tube is clogged causing ice buildup.
SOURCE: freezer quit then noticed fridge side not cooling
the relay on your compressor is bad go behind you refrigerator and take off the the bottom panel the relay is on the left side of your compressor usually
SOURCE: FREEZER ACCUMULATED WATER FROZEN NOW DRIPPING THRU TO FRIDGE
The drain in the freezer is blocked. Just below the cooling coils is a drain, when the defrost heater cycles on the water is suppose to go down the drain and into a pan under the ref.
SOURCE: My Whirlpool cb18m Fridge Freezer works fine but
check to see if the evaporator fan is working in the back of the freezer panel
SOURCE: The fridge of my American style fridge/freezer is
You can use a hairdryer on the frozen parts.
The fridge gets its cold air from the freezer through a vent(damper)
between the freezer and fridge.The fan in the freezer blows air through
it. There is a flap you adjust with the
fridge temp. control. Make sure it's opening and closing when you adjust the
fridge temp ..
SOURCE: freezer is making frost, fridge side doesn;t seem
The problem is most likely either the defrost timer, and/or the defrost heater element(s) are faulty. The problem is actually that the defrost heater elements are not functioning properly and the evaporator core is actually freezing up and blocking the air flow through the evaporator core and also freezing up the thermal sensor, and when that happens there is no longer enough cold air being circulated through the refrigerator (that is actually how the unit operates and air must be able to flow through the evaporator core and then be circulated throughout the refrigerator to properly function) and as a result the refrigerator stops functioning and food can even thaw out in the freezer although the freezer seems to be iced up. (Usually at the rear wall where the evaporator core is located)
(Air flow through the evaporator core and cold air circulation and re-circulation through the refrigerator is performed by the air circulation fan and it also must be functioning)
Be sure to only use a blow dryer (with a towel on the bottom of the freezer) to thaw out the evaporator core and do not use any hard or sharp objects or the evaporator core can be damaged. The defrost timer can be located inside of the refrigerator itself, (see lower image) or it can be mounted outside usually either behind the air intake cowl or kick panel at the front base of the refrigerator, or most likely located behind the service panel on the rear of the refrigerator, and usually if the defrost timer is turning then it is most likely working, however the defrost timer can move very slowly and you can place a mark on the timer and the housing to check after about fifteen minutes to see if the position on the defrost timer has changed. The deforst timer on newer digital models can be built into the circuit board and is not a seperate timer mechanism. The defrost heater coils can easily be checked by dis-connecting them and using an ohm meter, and a high or an infinite reading would indicate a faulty heater coil, however most of the time they are easily identified as being bad just by looking at them.
Here are some images that should be similar to your situation to help assist you, and let me know if you require any further assistance.