20 Most Recent Leviton 8299 Combination Switch / Smart lock GFCI Outlet - Page 6 Questions & Answers

0answers
0helpful
1answer

Wired in 5224 switch using (1) white wire and (3) black ones and it popped the breaker. I switched the wires and now both toggle switches control same light. The previous switch controlled a light and

10-25-12Copy following link for wiring diagrams for Leviton double switch.http://waterheatertimer.org/How-to-wire-switches.html#doubleOnly 3 wires will connect to switch. Not 4If you blew breaker than you connected Neutral wire to switch.Neutral wire never connects to switch.Identify Hot wire.There is only one Hot wire that carries power to switch box.This wire connects to one side of device ... which side? ... the side where both screws are bonded together. If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
10/25/2012 11:27:09 PM • Leviton... • Answered on Oct 25, 2012
0helpful
1answer

Crackling noise in light switch

Replace light switch.Switch has a short.http://waterheatertimer.org/How-to-wire-switches.htmlTake photo of switch and wiring before removing wires, so it is easy to re-identify what wire went to which terminal. If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
10/23/2012 7:13:28 AM • Leviton... • Answered on Oct 23, 2012
0helpful
1answer

Leviton programmable timer switch problem

Connect timer white wire to bare ground wire. This will complete circuit to 3 watt timer mechanism, and while this action is not 100% code, it will not pose much risk since the wattage is so low.Copy following link for illustrations and information:http://waterheatertimer.org/How-to-wire-timers.htmlhttp://waterheatertimer.org/Leviton-timers.html If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
8/7/2012 10:33:49 AM • Leviton... • Answered on Aug 07, 2012
0helpful
1answer

Circuit tester when plugged into 3 pronged plug, comes up with 2 green lights and 1 yellow light. There is no code on other side of tester to access this problem

Circuit analyzer does not show all possible problems, and tester might be defective.Use analyzer on other outlets.Buy another circuit analyzer.Buy a multimeter at local hardware, and test for voltage, and continuity, and compare with known outlet that are functioning correctly.For example outlet may be 240Volt instead of 120V.Copy following links to see typical circuit analyzer and code:http://waterheatertimer.org/images/Typical-circuit-analyzer-15.jpghttp://waterheatertimer.org/images/Outlet-polarity-200.jpg If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
6/30/2012 8:26:03 AM • Leviton... • Answered on Jun 30, 2012
0helpful
1answer

Electrical gfui reset keeps popping out. Located on patio.Does not lock[n position.

There is a short, or GFCI outlet is bad.Copy following links for help with GFCI:http://waterheatertimer.org/pdf/GFCI-outlet-will-not-reset.pdfhttp://waterheatertimer.org/How-to-wire-GFCI.html If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
6/30/2012 7:35:32 AM • Leviton... • Answered on Jun 30, 2012
0helpful
1answer

HOW TO WIRE A COMBINATION TWO SWITCH

Copy following link to see illustrations of switch wiring, including combination switch, and 3-way switches, double switches etchttp://waterheatertimer.org/How-to-wire-switches.html If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
6/30/2012 7:00:31 AM • Leviton... • Answered on Jun 30, 2012
0helpful
1answer

Can i use a Leviton slide dimmer no. 6631 with a holegen fixture

Incandescent and halogen appear the same to these switches. Basically, if the fixtures has a ballast or the lamp uses gas for illumination (as opposed to filament) it will require a special dimmer made expressly for that use or no dimmer is permitted. Such lamps would be fluorescent, compact fluorescent (aka CFL), high pressure sodium, mercury vapor, etc.There are also some DIMABLE CFLs on the market. These can be used with ordinary dimmers and require no special wiring. Simply remove the old incandescent and replace with a dimaable CFL. Be sure to read the package for any limitations. Keep in mind, the CFL package must state it is dimable, as not all are. Dimable CFLs cost more than the non-dimable types.Even though it was not asked, never use a dimmer to control the speed of a fan. That applies whether it is a paddle fan or a table fan plugged into an outlet that is controlled by a dimmer switch. There are variable speed motor controls made for this purpose.I hope this helps & good luck!
1/6/2012 11:23:53 PM • Leviton... • Answered on Jan 06, 2012
Not finding what you are looking for?
Leviton 8299 Combination Switch / Smart lock GFCI Outlet Logo

38 questions posted

Ask a Question

Usually answered in minutes!

Top Leviton Electrical Supplies Experts

john h

Level 3 Expert

29494 Answers

Sean Wright
Sean Wright

Level 3 Expert

2045 Answers

CJ Rock
CJ Rock

Level 3 Expert

4429 Answers

Are you a Leviton Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Leviton Electrical Supplies

  • Leviton Electrical Supplies

Most Popular Question

need electrical outlet scematic

  • Electrical Supplies
Loading...