I do not have the tech sheet, and getting F-7 code with electrical break sign what could I be looking at ? I have replaced the inverter board, so I am probably looking @micro switches can you help
F7 is q Power to magnetron
interrupted
1. Unplug microwave oven or disconnect power.
2. After 40 seconds, check to see whether this solves the problem.
3. Unplug microwave oven or disconnect power.
4. Check cooling fan operation
5. Check resistance of the magnetron thermostat.
6. Check the magnetron.
7. Check P2, P4 and P27 connections.
8. Check wiring to the 1100W inverters and control system. See
“Checking Inverters.”
9. Check operation of all interlock switches.
10. Replace inverter, if defective.
11. Replace all parts and panels before operating.
12. Plug in microwave oven or reconnect power.
13. If problem persists, unplug microwave oven or disconnect power.
14. Replace electronic control.
15. Replace all parts and panels before operating.
16. Plug in microwave oven or reconnect power.
17. If problem persists, unplug microwave oven or disconnect power.
18. Check for reversed plug connection on controls or loose wiring.
19. Replace all parts and panels before operating.
20. Plug in microwave oven or reconnect power.