I assume that you have already:
- Emptied the water buckets.
- Are sure the buckets are properly in place.
- Are sure the bucket switches are not stuck in the full bucket position.
- Cleaned the cooling coils.
- Verified that the controls are set for a low humidity
- Verified that there are no trouble lights or codes,
- Know that the area to be dehumidified is well above freezing..
It sounds like they are both stuck in defrost mode or the compressors overheated and need to cool off. "Both" is a bothersome word. Both might imply a power surge that wiped out the controls. I would:
- Unplug them and let them cool off 36 hours.
- Check your manual for a control panel reset.
- Take off whatever covers I could, to let me touch the cooling coils to be sure they get cool.
- Plug in # one and reset the panel.
- Let it run and see if the coils get cold.
- Plug in # two and reset the panel.
- Let it run and see if the coils get cold.
And then decided what to do next. Hopefully the cool off and reset did it .
Good luckl.
×