Anonymous Posted on Feb 12, 2010

LIGHT ON DASH FOR GLOW PLUG NO LONGER COMING ON AND L200 NO LONGER STARTING FUSE FOR GLOW PLUGS GOOD BUT NO POWER TO CONNECTING PLATE FOR GLOW PLUGS ANY IDEAS

  • doug t Jan 20, 2014

    SERVICE SPECIFICATIONS 16400030025 Item Standard value Resistance between glow plug plate and glow plug body (parallel resistance for 4 glow plugs) (at 20

×

1 Answer

steve morris

Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

  • Mitsubishi Master 1,675 Answers
  • Posted on Feb 12, 2010
steve morris
Mitsubishi Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Joined: Jan 30, 2010
Answers
1675
Questions
0
Helped
653656
Points
5484

This sounds like the glow plug relay is u/s or stuck, locate the relay in your fues box and give it a tap or remove it and replace it, it might have just come loose, if this does not work it will need replacing...hope that helps

Testimonial: "thanks for the advice looks like the root of the problem waiting on new part/relay cheers much appreciated"

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

My ford 6.7 diesel cranks over fast,but does not start

There can be several reasons for this. The cheapest reasons to look at are spark to the glow-plugs and fuel to the cylinders. If you have a "ready light" on the dash that tells you when the glow-plugs are ready, you need to listen for the clicking of the glow-plug relay and the blinking of every other light that is on in sync with the clicking sound.

If the clicking and light dimming is not observed your power relay to the glow-plug relay is probably bad. A voltmeter will be needed to test for juice passing through the the power relay. If you have juice going to the glow-plug relay from the power box relay and it does not cycle off and on, your glow-plug relay is bad or the glow-plugs are bad.

You can test the power to each glow-plug with a test light or meter (when the power relay and glow-plug relay are cycling). Glow-plugs are similar to spark plugs and they can be tested. It can be tricky or you can just replace them.

Fuel, this time of year is subject to freeze-ups. Additive will help, noting Diesel additive and NOT gasoline additives. In short, Pyroil makes a starting fuel which has protective oil in the spray to help the cylinders. A spray of starting fluid will diagnose that fuel starvation is the problem. It is tricky to use when the glow-plugs are hot. On injector systems with O rings the cold weather can sometimes cause the O rings to shrink when sitting and leak. Your fuel will run back to the tank. Cranking will not be enough to draw up the fuel. Another way is to change fuel filters BUT to put some diesel into the fuel filter to prime the system. No guaranty that the problem will not reoccur because you have not permanently fixed anything. Hope this helps, if not then something has let loose like a fuelpump.
1helpful
1answer

1992 Ford F350 7.3 Diesel, put in new glow plug controller, controller clicks off and on, but no power to glow plugs. What could cause this?

Hi Margaret , Does the glow plug wait to start indicator light on the dash come on ? And then go off after a couple of min. ? Check fuse K 20 amp in the under hood fuse box .This is one of three B+ power supplies to the glow plug control module > Two fusible link's are also B+ power supplies to the module . There is a 10 amp fuse located in the inside fuse box , fuse # 17 , this is power for the indicator light !
1helpful
1answer

How are you supposed to start a l200 on a 04 plate properly

the owners hand book will have the starting procedure but as a rule with a diesel you wait for the glow plug light to go out, depress clutch , as with all cars depressing the clutch reduces the energy required to turn engine over as the gearbox is disengaged, and start engine , there should be no need to use the accelerator to get the engine to start, hope this helps
1helpful
1answer

Light on dashboard for glow plug warming up on my mitsubishi pajero not coming on

replace the light illuminator on dash test light to see if your getting an electrical connection thats simple and its dyi
0helpful
1answer

GLOW PLUGS

the glow plugs work through a relay so check the relay and wiring for the relay from the ignition switch
0helpful
1answer

1996 fiesta ghia diesal no glow plug light

No power to the glow plugs means no power to the light also. You have a bad fuse or connection to the glow plug relay. Fix that and your good to go. Has nothing to do with your indicator lights on either side of dash. Glow Plug power indicator is labeled THAT and only that.
2helpful
1answer

Glow plug light not coming on, on dash. Engine turning over but not starting. Have never had any trouble starting before. The fan belt has been screeching for about 30 seconds for the last few weeks when...

Check fuses to see if there are busted ones. Then check heater plugs if good. Heater relay included in check. Engine wont fire if the air inside the chamber is cold. Then check fan belts for wear, replace if necessary.
1helpful
1answer

88 f250 diesel ticks hard pumps smoke still starts good and no power loss, took vavle cover off and everything looks ok wat should i check next wat would i look for if i was to pull injectors

The problem is the glow plugs are bad or not coming on. Even though the "wait to start" light comes on, the glow plugs may not come on. I have found when this happens, the light comes on for only 1-2 seconds and goes off. With the engine cold, the light should stay on for about 5 to 7 seconds. The colder the engine, the longer the plugs should stay on. There is one glow plug for each cyl. The plugs are in the "V" of the engine and screwed into head. Only one wire goes to the glow plug and the wire runs from one plug to the next on each bank. You test them by removing them and grounding the body and putting 12v positive to the terminal. The tip should glow red hot like a cigarette lighter. There is a glow plug relay behind the air intake horn which also could be the problem and there is a engine temp sensor in the circuit also.
1helpful
1answer

Glow plugs causing starting problem

if you need connectors and terminals for the glow plug connections under the valve cover, Ford sells then so you don't need a whole $600 harness.

info for your use

Section 03-07B: Glow Plug System 1996 F-250, F-350, F-Super Duty Equipped with 7.3L Diesel Engines Workshop Manual
DESCRIPTION AND OPERATION Glow Plug System The 7.3L diesel engine uses a glow plug system which preheats air in the combustion chamber to improve cold engine starting. The system consists of eight glow plugs, the glow plug control module (12B533), powertrain control module (PCM) (12A650), engine oil temperature (EOT) sensor and barometric pressure sensor (BARO sensor) (12A644). The glow plug system is electronically controlled by the powertrain control module. The powertrain control module energizes the glow plugs immediately after the key is placed in the ON position and then determines how long the glow plugs will be on according to the engine oil temperature and the barometric pressure. The required time for the glow plugs to be energized decreases as the engine oil temperature and barometric pressure increase. The glow plugs are self-regulating, and the powertrain control module controls relay ON time. The powertrain control module protects the glow plugs by energizing them for short durations if the battery voltage is abnormally high.

Possible Causes: Insufficient glow plug ON time will not allow enough heat to accumulate in the combustion chamber to easily facilitate starting. If the glow plug system ON time does not meet any of the specifications in the accompanying chart the problem is most likely a faulty wire harness connection, ground connections or glow plug relay.

If the glow plug resistance to ground is high, the most likely causes are an open UVC (under valve cover) harness or open glow plug.
--------------------------------------------------------
Relay Operation
Install a DVOM on the glow plug feed side of the glow plug relay (large stud with two wires connected). Turn the ignition key to the ON position but do not attempt to start. Note the time in seconds from when the key is turned on and the glow plug relay energizes until the glow plug relay de-energizes. The glow plug relay makes a loud click noise which is easily heard when it energizes and de-energizes. The dome light will dim and the dash voltmeter will dip when the glow plugs are drawing current from the battery. Compare the times measured to the table (time will be affected by engine temperature, battery condition and vehicle altitude). The voltage at the glow plug feed terminal may vary from 9 to 12 volts depending upon battery condition.
--------------------------------------

-----
If battery voltage not present check for B+ at power supply terminal (terminal with single large wire). Power for glow plug power supply is supplied from starter relay through two fusible links at solenoid.
Glow Plug Operation
Disconnect all of the glow plug/injector harness connectors from the valve cover gaskets. With the pigtail installed, measure glow plug resistance to ground (preferably B-). A resistance measurement of .1 to 6 ohms indicates a good glow plug.



Glow Plug Harness Continuity
Measure for continuity from the connector harness to the glow plug feed terminal on the glow plug relay. Resistance should be less than 5 ohms.
Incorrect measurements will result if all glow plug/injector connectors to valve cover are not disconnected.

---------------------------------------------------
Glow Plug Relay The glow plug relay (12A343) has a plastic base and two mounting bolts. It is operated by the powertrain control module (PCM) (12A650) which senses engine oil temperature, PCM voltage and barometric pressure. When the engine oil temperature or the barometric pressure is low, the PCM activates the glow plug relay and the glow plugs. If the PCM voltage is too high, the powertrain control module deactivates the glow plug relay and the glow plugs immediately energize for a shorter duration, decreasing the modulation of the duty cycle.
-----------------------------------------------
Glow Plug Removal
  1. stj~us~en~file=ani_caut.gif~gen~ref.gif WARNING: THE RED-STRIPED WIRING HARNESS CARRIES 115V DC. SEVERE ELECTRICAL SHOCK MAY BE RECEIVED. DO NOT PIERCE.
    Remove valve cover (6582). Refer to Section 03-01D .
  1. Disconnect glow plug electrical connector using a pair of pliers.
  1. Remove glow plug using 10mm socket.
  1. Clean and inspect glow plug tip for damage. Replace if damaged.
Installation
  1. Install glow plug and tighten to 19 Nm (14 lb-ft).
  1. Connect glow plug electrical connector. Make sure glow plug wiring is routed to avoid moving parts.
--------------------------------------------------------------
Glow Plug Control Glow plugs are used to warm the cylinders to improve cold-engine starting. The PCM uses the engine oil temperature (EOT) sensor and barometric pressure (BARO) sensor to determine how long the glow plugs will be on. The PCM energizes the glow plugs longer if the engine is very cold or if the barometric pressure is low at high altitudes.
The PCM controls the relay that supplies power to the glow plugs with the glow plug control (GPC) signal. When the GPC signal is grounded by the PCM the relay closes, turning the glow plugs on.
The glow plugs are controlled by the following sequence:
  1. PCM energizes the glow plugs.
  1. The PCM energizes the glow plugs immediately after the ignition is placed in the ON position.
  1. The PCM then determines how long glow plugs will be on based on EOT sensor and the BARO sensor. The required time to warm up the cylinder decreases the engine oil temperature and barometric pressure increases at low altitudes.
Glow Plug Lamp Control The glow plug lamp (GPL) signal controls the WAIT TO START light located on the instrument panel. This light is used to indicate when to start the engine. The cylinders are being warmed by the glow plugs during and after this light is lit. The PCM energizes the glow plug lamp longer if the engine is very cold or if the barometric pressure is low.
When the GPL signal is brought low, the "Wait to Start" lamp is turned on.
The glow plug lamp is controlled by the following sequence:
  1. PCM lights the WAIT TO START light after a key on reset occurs.
The PCM determines the glow plug lamp activation time based on engine oil temperature, barometric pressure and battery voltage.
  1. PCM turns off the WAIT TO START light.
The glow plug lamp is turned off when the timer counts to the number of seconds specified by the PCM. The glow plugs will normally remain on longer than the "Wait to Start" lamp.
-----------------------------------
0helpful
1answer

2000 tdi wont start!!!

glow plug relay is marked #180 on the housing.
in 0 to 11 degrees they have a starting prob were the glow plugs go on and off very quickly.need VAG.com to exstend glow plug timing.
to test glow plugs disconeect ect turn key on plugs should draw 15 amps each 60 amps all together.if you dont have amp meter use test light.
Not finding what you are looking for?

1,395 views

Ask a Question

Usually answered in minutes!

Top Mitsubishi Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Thomas Perkins
Thomas Perkins

Level 3 Expert

15088 Answers

john h

Level 3 Expert

29494 Answers

Are you a Mitsubishi Expert? Answer questions, earn points and help others