Kohler Electrical Supplies - Page 8 - Recent Questions, Troubleshooting & Support

0helpful
1answer

Can I see a copy of order?

You need to request this from whomever you purchased the generator from.
6/2/2015 2:49:45 AM • Kohler 14RESA... • Answered on Jun 02, 2015
0helpful
1answer

Trying to find what oil filter can be used in 14KW Kohler

what is the filter part number on the Generator now? Give that to an Auto parts place and they will cross it to what they sell
5/25/2015 8:53:02 PM • Kohler... • Answered on May 25, 2015
0helpful
1answer

My kohler 5750009 generator will run perfect for about 2 hours then shuts off. It will restart. What should I check?

See if there is a heat shield for spark plug. Make sure proper plug is installed and gapped.
5/19/2015 10:54:59 PM • Kohler... • Answered on May 19, 2015
0helpful
1answer

How ca someone figure a compression ratio on a kohler command engine with different heads?

the compression ratio has nothing to do with head shape - it is the of the swept volume of the cylinder compared to one ( surface area X the stroke of the piston)
5/12/2015 12:56:14 AM • Kohler... • Answered on May 12, 2015
0helpful
1answer

Kohler cv 15s starts up runs a few seconds n stops dead, any idea why?

plugged fuel line or stuck float
5/11/2015 2:08:10 AM • Kohler... • Answered on May 11, 2015
0helpful
1answer

This shower has 3 body spray jets. The lower jet does not work. I need to remove the lower one to see if there is debris in the line, blocking it. It is a Kohler k 8002 cp body jet. How do I disassemb

There are some clips on the top of the spray head that fasten it into place. I found this pic that may help and your Kohler owner's manual should also have more info. 25592176-ozvmlizmijhtkjqpyt2ubpar-3-0.jpg
3/19/2015 1:34:29 PM • Kohler... • Answered on Mar 19, 2015
0helpful
1answer

When starting ignition it drags, after turning by hand it will spin over with starter

Make sure the oil pump has been primed and the pressure is ok . After it starts it should free up . make sure the ignition timing is ok and the battery is fully charged.
3/13/2015 4:48:09 AM • Kohler 26HP... • Answered on Mar 13, 2015
0helpful
2answers

Oil is pumping into the carb adn air filter of my kohler 2 cylinder workman engine

Make sure you have good compression. Sounds like you have blow-by. Crankcase vents into the air box.
3/7/2015 9:38:12 PM • Kohler CH25... • Answered on Mar 07, 2015
0helpful
3answers

Engine not charging battery engine dies when

When you remove the battery it will break the circuit and die and if your battery dosen't have at least 5v in it it won't charge and you will have to replace it.
3/4/2015 12:51:28 AM • Kohler CH25... • Answered on Mar 04, 2015
0helpful
1answer

Kohler 7.3e marine generator exhaust is coming out of valve covers. It's not blow by and I've check the valves are not sticking and gaped properly.

Valve seats, valve integrity, intake seals. Perform a leakdown test to further diagnose
3/3/2015 3:29:15 AM • Kohler 12 kW... • Answered on Mar 03, 2015
0helpful
1answer

WHAT IS THE MOST LIKELY CAUSE OF AN AUXILIARY FAULT ON A KOHLER GENERATOR MODEL 80ROZJ

Check radiator coolant fill right to the top, if it has a low level switch or faulty switch I have seen this
3/2/2015 6:55:05 PM • Kohler Generator... • Answered on Mar 02, 2015
0helpful
1answer

WHAT WOULD CAUSE A AUX FAULT ON A KOHLER GENERATOR MODEL 80ROZJ

Aux fault can be many things, if it failed to start you may get it. Try reseting and manually starting. See if it re-occurs while it is running or does it ever start and give error. I have seen this generator by a coolant level sending it is an auxillary fault
3/2/2015 6:54:18 PM • Kohler Generator... • Answered on Mar 02, 2015
0helpful
1answer

How to identify older years and models of Kohler generators?

What do you mean? same as any model and serial number plates. Commercial? residential? the same
3/2/2015 6:52:13 PM • Kohler... • Answered on Mar 02, 2015
0helpful
1answer

I have a 17res that starts for a couple of seconds then shuts off. Repeats every 15 minutes or so. Can't manually start it with run button after this happens. What's wrong?

You may have a fuel issue, check that first. Check WC pressure on regulator, check shut off solenoid. Do this first.
3/2/2015 6:50:59 PM • Kohler 17 kW... • Answered on Mar 02, 2015
0helpful
1answer

What would be the cause of a Kohler 25hp twin, backfiring through carb from one cylinder

Bad plug, ignition wire, valve clearance, or valve damage, vacuum leak at manifold. Timing cam off / damaged
3/2/2015 6:48:44 PM • Kohler CH25... • Answered on Mar 02, 2015
0helpful
1answer

How to clear a main power overload on a kohler gen

What is missing here is a couple of things, what size generator are we talking? a residential, commercial, what control is on the unit. They all reset in different ways. One sure way is disconnect the battery charger first (VERY IMPORTANT or control board can be damaged) disconnect the negative terminal off the battery. leave off for a minute they re conenct and re energize charger. Fault should clear unless you have done damage due to over load.
3/2/2015 6:43:25 PM • Kohler... • Answered on Mar 02, 2015
0helpful
2answers

What does it mean when my gen give me a code ou 23EOZD

That is over voltage
3/1/2015 11:29:55 PM • Kohler 23EOZD,... • Answered on Mar 01, 2015
Not finding what you are looking for?
Kohler Logo

677 questions posted

Ask a Question

Usually answered in minutes!

Top Kohler Electrical Supplies Experts

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66980 Answers

Are you a Kohler Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...