Bunn Ultra 2 slushee machine not freezing
Hmm, that's definitely a problem! From what I understand, the Bunn Ultra-2 slushy machine is supposed to freeze evenly on both sides. So if it's only freezing on one side, there could be a few different things going on. It could be an issue with the refrigerant level, the solenoid, or the optical sensors. Can you tell me a bit more about the symptoms of the problem? For example, is the side that's not freezing completely warm, or is it just not getting as cold as the other side?
I cant see my BUNN BT Velocity date code on my brewer I was told it is 6 digits... it starts with what number??
To locate the date code on your BUNN BT Velocity brewer, you can try the following:
- Check the bottom or back of the brewer: Look for a label or sticker on the bottom or back of the machine. The date code is typically printed on this label.
- Inspect the sides or inside the brewer: In some cases, the date code may be located on the sides or inside the brewer. You may need to remove any panels or covers to access the label or sticker.
- Consult the user manual: If you have the user manual for your BUNN BT Velocity brewer, it may provide information on where to find the date code. Refer to the manual for specific instructions or contact BUNN customer support for assistance.
If you are still unable to locate the date code on your brewer, I recommend reaching out to BUNN customer support directly. They will be able to provide you with accurate information and guide you in finding the date code on your specific model of the BT Velocity brewer.
I have a bunn ultra 2 slush machine.everything comes on its just the compressor kicks on and right off afterwards not allowing product to freeze.what could be the problem.thanks in advance
If your Bunn Ultra 2 slush machine's compressor is turning on and off immediately, not allowing the product to freeze, there could be a few possible causes. Here are a few things you can check:
- Check the thermostat: Make sure that the thermostat is set to the correct temperature and that it is functioning properly. A faulty thermostat can prevent the compressor from turning on.
- Check the compressor relay: The compressor relay is responsible for turning the compressor on and off. If the relay is faulty, the compressor may not stay running. You can check the relay by using a multimeter to test for continuity across the relay's terminals.
- Check the compressor motor: The compressor motor could be faulty and not able to start or stay running. You can check the motor by using a multimeter to test the winding resistance.
- Check the condenser coils: The condenser coils could be dirty or clogged with dust, which can cause the compressor to overheat and shut off. Clean the condenser coils with a brush or compressed air to remove any dust or debris.
- Check the compressor's oil level: If the oil level is low, the compressor could be damaged.
- Check the overload protector: The overload protector is a safety device that is designed to protect the compressor from damage caused by excessive current. If the overload protector has tripped, the compressor will not start or stay running.
It's worth noting that a compressor not staying running could also be caused by a more complex issue
My BUNN Ultra 2 Slushy Machine is freezing just one side.
It sounds like you have already identified the issue with your slushy machine, which is that one of the auger drive shafts is not functioning properly. Based on the information you provided, it seems that the problem may be related to the length of the pin on the auger drive shaft.
As for a potential solution, it's possible that replacing the auger drive shaft with one that has a properly sized pin may fix the issue. Alternatively, you could try to adjust the length of the pin on the existing auger drive shaft, but this may be difficult to do without the proper tools and expertise.
As for your suggestion of using a jumper to take the voltage from one solenoid and apply it to the other, this may not be a good idea. Solenoids are designed to control the flow of electrical current, and bypassing one in this way could potentially cause problems with the overall functioning of the slushy machine. It's always best to follow the manufacturer's instructions and use the machine as intended.
In summary, it may be best to replace the faulty auger drive shaft with a new one, or seek the help of a professional to properly adjust the existing one. It's generally not recommended to bypass or alter the functioning of the solenoids in your slushy machine.
How do I get the
This brewer has a 2 1/2 pot reservoir. You should NOT plug in the brewer before the reservoir has been topped off. Pour 3 pots (one at a time, every minute or so) through the screen with a pot under the filter basket. Wait until the water flows from the basket and only then is it safe to plug in the brewer. The reservoir holds HOT water until you are ready to brew and then, by pouring in a pot of cold water, you will be able to brew.