How to use fume hoods?
I remember how at the University at the first laboratory work I was almost exposed to all harmful fumes. The teacher made me write an entire essay on safety at work. I turned to
Paperial.com for writing a quality essay. But since then, there have been no such incidents. Therefore, carefully read the safety precautions and the most important advice: to improve how well fumes are taken up and away, put your reactions or equipment as far back in the fume hood as you possibly can.
When turn on the pump, the green light on manual set pop up, though non of the bottom works, what's wrong?
www.dionex.com/en-us/webdocs/29146-CM_670_E_
Manual.pdf
DionexAdvanced Gradient Pump (AGP). AD20 UV/Vis Absorbance Detector. AES® Atlas Electrolytic Suppressor. Alliance® (Waters Corp.) AminoPac® Columns.Missing: 6200 green light
www.fixya.com/.../p5939790-
hitachi_intelligent_
hplc_
dad_
detector_pu
Recent Hitachi intelligent HPLC DAD detector pump L-6200 questions, ... Looking for a manual for a 71260 propper branded made in japan ... BAD SLIDER OR DIMMERSWITCH MAYBE THE CIRCUIT BOARD IS BAD ALSO. ... There is no light and wondering how to replace a battery and where to find ... LET ME SING UP.Missing: green pop
hitachi-hta.com/sites/default/files/.../
Hitachi_Prices_2012_04_21_rev2.p...
12/21/2015 5:51:41 PM •
Hitachi...
•
906 views • 0 helpful votes
How to fix p0089
Hi Lester David, I want to help you with your question, but I need more information from you. Can you please add details in the comment box?
11/28/2015 4:24:07 PM •
Science &...
•
1,238 views • 0 helpful votes
Why no blind spot dectected
The two most common problems when trying to find a blind spot are: A.) Forgetting to patch the eye, and B.) Choosing the correct eye in the machine itself.
Error 2 in 5417R,how do i solve it?thanks
Error 2 on this model indicates that the imbalance sensor is tripped. If you run the unit with an empty rotor and it does not error, then it simply means that your load was imbalanced. Make sure to put vials into the unit opposite each other, as below.
If it displays "Error 2" with an empty rotor and you did not notice a vibration, then the imbalance sensor is broken and must be replaced. Do not attempt to run the centrifuge without the imbalance sensor, as serious injury may result.
I repair these machines, but you would have to ship it to me in Ohio, which would probably be very expensive.
Here is a rotor balance chart:
8/13/2015 7:57:46 AM •
Eppendorf...
•
3,472 views • 1 helpful votes
Where can I buy a new light bulb for it?
it will be a specialized bulb so try camera shops the sell microscopes
try the manufacturer on line for a distributor / authorized service agent for parts
9/20/2015 6:05:23 AM •
Science &...
•
911 views • 0 helpful votes