Top 20 Samsung AQV36JA Classic 36000 BTU Single Zone Ductless Heat Pump Mini Split Air Conditioner System Questions & Answers

0helpful
1answer

What kind unit is

This type of unit is called a Mini Split Air Conditioner. Hope that helps you check us out at Air Duct Cleaning
11/2/2015 3:05:09 AM • Samsung AQV36JA... • 174 views • 0 helpful votes
0helpful
1answer

Why my unit keep shutting off after few seconds and then turbo light keep on flashing?

Operation = Flashing Display Timer = Yes Turbo = LED Display = E1 Explanation and Checking points = Indoor unit room thermistor error - Open or Closed Circuit - Check and replace if required Operation = Yes Flashing Display Timer = Yes Turbo = LED Display = E2 Explanation and Checking points = Indoor unit pipe thermistor error - - Open or Closed Circuit - Check and replace if required Operation = Flashing Display Timer = Turbo = Yes LED Display = E3 Explanation and Checking points = Indoor unit fan motor malfunction - Check and replace if required Operation = Flashing Display Timer = Yes Turbo = Yes LED Display = E6 Explanation and Checking points = EPROM error - Check and replace PCB if required Operation = Yes Flashing Display Timer = Yes Turbo = Yes LED Display = Flashing Explanation and Checking points = Option code error - Check and input new option code if required via wireless remote controller Operation = Yes Flashing Display Timer = Turbo = Yes LED Display = Explanation and Checking points = Outdoor unit temperature sensor - Open or Closed Circuit - Check and replace if required
6/18/2014 10:26:55 PM • Samsung AQV36JA... • 1,870 views • 0 helpful votes
0helpful
1answer

Samsung ac indoor unit is on outdoor unit is not

check the power cable between the two.
6/18/2014 11:34:25 PM • Samsung AQV36JA... • 219 views • 0 helpful votes
0helpful
1answer

Samsung VRF System. One of the indoor unit of it is not working. What error code will it display?

I answered this earlier and still no model number.

Samsung DVM S Error Code Booklet

GT Phelan https://gtphelan.ie > uploads > 2019/07 > DVM-... PDF Welcome to the new Samsung Error Code Booklet, for our repair network. This booklet has been designed to offer on site assistance for fault code. 39 pages

Samsung VRF Air Conditioner Fault Codes

samsungvrf.com.tr https://www.samsungvrf.com.tr > samsung-vrf-klima-a... Samsung VRF Service Fault Codes and Solutions ; 147, Closed EVA2_in Sensor Break Away Error ; 148, Closed EVA2_OUT Sensor Break Away Error ; 149, AHU Master Indoor ... ..
2/15/2024 2:33:38 AM • Samsung Heating... • 26 views • 0 helpful votes
0helpful
1answer

What does the code E4 mean on my Samsung range

These are error code list of samsung range Samsung range or wall oven error codes
12/9/2023 12:22:50 PM • Samsung Heating... • 40 views • 0 helpful votes
0helpful
1answer
0helpful
1answer

Samsung digital inverter ac c1 error code

The C1 error code on a Samsung digital inverter AC usually indicates a communication error between the indoor and outdoor units. This could be caused by a faulty control board or a wiring issue. To troubleshoot this issue, you can try resetting the unit by turning off the power supply for a few minutes and then turning it back on. If the error persists, you may need to call a professional technician to diagnose and fix the issue. They may need to check the wiring connections and replace any faulty parts if necessary.
11/1/2022 5:47:26 AM • Samsung Heating... • 800 views • 0 helpful votes
0helpful
1answer

Samsung AQ12FAN, indoor unit starts on it's own, and stops after a few seconds.

Hi, It could be that the motor for the device needs to "warm up". Everytime it stops the internal thermostat sees that the target temperature has not been reached so it starts the internal motor again. This happens in a cycle until the motor gets warmed up or the target temperature is reached. This is my hypothesis. So, you might need to get the devices's motor checked out. Thank you.
6/5/2022 5:02:48 PM • Samsung Heating... • 163 views • 0 helpful votes
0helpful
1answer

My Samsung AQ12UGQN Split Unit heating has all 3 lights flashing green!

Either the new control board is faulty, or the connections are bad, or the issue is somewhere else. The main problem is that you are not an air conditioning / heating engineer. Some things are not home owner fixable.
3/18/2022 6:32:45 PM • Samsung Heating... • 91 views • 0 helpful votes
0helpful
1answer

Samsung A/C remote #DB93-03012K. How to change from centigrade to fahrenheit?

Better to learn Centigrade as it it so simple. 0' is freezing point of water, 100' is boiling, your home needs to18'C Details here! https://www.google.com/search?q=Samsung+A%2FC+remote+%23DB93-03012K.+How+to+change+from+centigrade+to+fahrenheit ..
6/29/2021 11:49:40 PM • Samsung Heating... • 354 views • 0 helpful votes
0helpful
1answer

Samsung Air Conditioner. What does error codes mean? E 101 and A 255 code

All FIXYA questions MUST have make model (what it is) This appears to be a Samsung Air Conditioner? I have moved you from Cars and Trucks, and FIXED your Question! https://www.google.com/search?safe=off&rlz=1C1QJDB_enCA643CA644&sxsrf=ALeKk01oIaILRRZkKWpSw__ZIb_xruN8Tw%3A1615332888677&ei=GAZIYPLgKOiE_Qbt15nIAg&q=Samsung+AC+E+101+and+A+255+code ..
3/9/2021 8:30:47 AM • Samsung Heating... • 866 views • 0 helpful votes
0helpful
1answer

Samsung air conditioner Error E468

Possible manual, depending upon model which has not be provided in your posting. https://www.manualslib.com/manual/1626579/Samsung-Am053fxmdch.html?page=56 Other web sites simply state "current sensor error" without explanation. You may need to pay professional repair, or purchase a replacement air conditioner.
7/6/2020 8:56:24 PM • Samsung Heating... • 612 views • 0 helpful votes
0helpful
1answer

Samsung split unit yellow on out door unit flashes and ac not turning on

Count the number of flashes between the pauses and let us know
2/21/2020 3:33:07 PM • Samsung Heating... • 176 views • 0 helpful votes
0helpful
1answer

Having error code of e154 on Samsung ac please what will it be the fult and how to solve it

E154 Error in Samsung Air-Conditioners If E1 and then 54 is displayed on the display panel after switching on the air-con, this indicates fan motor or capacitor is defective. Replacement is needed.
9/14/2019 8:13:03 AM • Samsung Heating... • 3,566 views • 0 helpful votes
0helpful
1answer

What is the problem when error 438 appears on a samsung dvm plus 4 outdoor unit

Error code 438 indicates a problem the EEV (electronic expansion valve) opening. This problem would require a trained technician to correct.
5/1/2019 2:58:22 PM • Samsung Heating... • 3,308 views • 0 helpful votes
0helpful
1answer

Samsung. AR18mv5HEWKXNA E2 01 Prablam

That error number is not listed in the owners manual. Perhaps you are reading the LEDs incorrectly. On page 47 of this manual is a list of error codes and causes which includes the LED displays. http://downloadcenter.samsung.com/content/UM/201701/20170119144127207/INV_User_Install_Manual_DB68-02124C__18-11-2016_REV._07-12-2016.pdf
2/27/2019 7:17:36 AM • Samsung Heating... • 68 views • 0 helpful votes
0helpful
1answer

I have a have a air con unit Samsung silver nano health system, not sure how to clean the filter

Hi there's this website something like reliable-store and it is very amazing for manual for repairing servicing anything someone on fixya recommended it to me and I thank him even today
1/31/2019 5:51:22 AM • Samsung Heating... • 135 views • 0 helpful votes
Not finding what you are looking for?
Samsung AQV36JA Classic 36000 BTU Single Zone Ductless Heat Pump Mini Split Air Conditioner System Logo

Popular Tags

5 questions posted

Ask a Question

Usually answered in minutes!

Top Samsung Heating & Cooling Experts

Cindy Wells

Level 3 Expert

6688 Answers

Brad Brown

Level 3 Expert

19187 Answers

jws1013

Level 3 Expert

1713 Answers

Are you a Samsung Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Samsung Heating & Cooling

  • Samsung Heating & Cooling

Most Popular Question

kind unit

  • Heating & Cooling
Loading...