You have Honeywell electronic gas control valve, and error code is 7 flashes.
Probably you have power vent model.
One manual from different company says: "Reset gas control using on-off button on front of control, replace flammable vapor sensor, replace gas control thermostat.
But with Rheem you also need specific steps: Remove gas burner and look for broken glass vial, and then blow out arrestor screen air intake using compressed air, clean burner parts, check for unobstructed venting, you will need new glass vial from Rheem depending on year and model number of water heater that appears on label on side of unit, or they may
not have a repair kit for that model, and you might need a new gas control valve depending on model and how extensive problem was
You have Rheem water heater.http://waterheatertimer.org/How-to-repair-Rheem-FVIR.htmlhttp://waterheatertimer.org/How-to-troubleshoot-gas-water-heater.html#intelliventhttp://waterheatertimer.org/How-to-replace-thermocouple.html If you need further help, I’m available over the phone at
https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
×