Nozzle check must perfect for perfect output. There are tranversal lines at vertical straight lines that represent same point of head micro piezo. If tranversal lines no clog at all, but vertical straight lines not perfectly straight, the result not good (like horizontal white banding). Check it? Head aligment is for vertical banding. If your result is horizontal banding, you don't need to realign head. It's caused by some residual at the output of head sprayer. So, the spray of ink not straight to paper. Try to print with photo/best photo.
Testimonial: "Thank you very much, its been more than a year now, no problems.."
754 views
Usually answered in minutes!
×