20 Most Recent Rheem Direct Vent Natural Gas Tankless Water Heater For 1-2 Bathroom Homes Questions & Answers

0answers
0helpful
1answer

Heater takes more than 1 minute to get water to

1) Guesses: Sounds like a bad single-handled faucet cartridge, or low water flow at faucet, or clogged water filter.
Replace faucet cartridge, clean the aerator, and/or clean sediment out of pipes below sink, and clean water filter at tankless unit each month.

2) For exact measure of problem:
Typical faucet can have 2 gallon per minute flow rate.
2 gpm flow rate means faucet fills 1 gallon container in 30 seconds. Test faucet using 1 gallon container and a cooking timer to get flow rate.
Clean aerator to improve flow rate. Compare kitchen flow rate with other faucets in home.
http://waterheatertimer.org/Low-hot-water-pressure.html

Most homes have 1/2" diameter pipe running to kitchen faucet.
100 feet of 1/2" diameter pipe holds 1.2 gallons of water. This assumes no sediment build-up inside pipes.
http://waterheatertimer.org/Water-heater-recirculation-system.html

Assuming only hot is turned on: If faucet is 100 feet away from water heater, and pipe diameter is unobstructed 1/2" diameter, and faucet has 2 gallon per minute water flow, then hot water should arrive in 36 seconds.
50 feet away, and hot water should arrive in 18 seconds.

If kitchen has single handled faucet, and the handle is raised in the middle, then equal amounts of hot and cold water are drawn at same time. This doubles amount of time for hot water to arrive.

If single handle faucet has a bad cartridge, then faucet can have crossover.
Crossover means that cold water can enter the faucet even if faucet is turned to hot.
Bad single-handled faucet cartridge can delay or stop the arrival of hot water.
http://waterheatertimer.org/Crossover.html

Tankless require maintenance including cleaning combustion parts yearly, de-lime heat exchanger frequently, and clean water filter each month.
http://waterheatertimer.org/pdf/Tankless-maintenance.pdf
http://waterheatertimer.org/pdf/Bosch_Overcoming_fluctuating_temps.pdf
http://waterheatertimer.org/Troubleshoot-Rheem-Tankless-water-heater.html

Add a comment for more help.

Take a moment and rate answer for accuracy:
And take advantage of fixya expert assistance live.
For a price, expert works with you while you work on water heater or any do-it-yourself project.
Fixya is always less expensive than a service call.
9/15/2011 3:05:37 AM • Rheem Direct... • Answered on Sep 15, 2011
0helpful
1answer

Squealing noise inside the tank

Does the water come out really hot while it is squealing? This is sounding like the water flow is not fast enough and is heating to almost a boiling point. I have experienced this myself with gas heaters. If you open the hot water valve more in your bath or shower does the sound go away?
1/29/2011 11:36:14 PM • Rheem Direct... • Answered on Jan 29, 2011
0helpful
1answer

Loud Vibration/Noise when System Starts

This happen when there is air in the gas line...if the problem is still there after a couple of days you will have to return the unit for an exchange the gas control is giving problem...contact rheem first before making a exchange decision..they will walk you some step first to ensure there is not a problem
8/12/2010 2:53:52 AM • Rheem Direct... • Answered on Aug 12, 2010
0helpful
1answer

I have a Rheem single element water heater and it won't heat I've replaced the element. What else could be the problem?

Check and reset circuit breakers or fuses, examine the power cord, assess water pressure, and verify thermostat settings.
4/26/2024 3:28:13 AM • Rheem Water... • Answered 7 hours ago
0helpful
1answer

Rheem water heater low water pressure

I got a new Rheem heater and it's complete garbage. No water pressure.
2/11/2024 7:21:23 PM • Rheem Water... • Answered on Feb 11, 2024
0helpful
1answer
0helpful
2answers

Rheem 42VP50FW won't light? Ignitor lights though

The three most common reasons for this happening to you are 1) a defective gas valve, 2) a rusty thermopile, and/or 3) the automatic shut-off not working as it should. So, the most common reason for many people having this problem stems from having a gas valve that is not working as it should. When your gas control valve is faulty, it will mean that your burner is not going to be igniting as it should-or at all. Something that worked for me one time was to turn the Temp all the way down then all the way to Max a couple of times..gradually. Why it worked I don't know. Got a couple more years out of it though. Good luck! Best to you.
9/4/2023 3:23:16 PM • Rheem Water... • Answered on Sep 04, 2023
0helpful
1answer

How do I adjust water pressure on Rheem water system 111250

there is pressure adjustment, just temp. water pressure in + water pressure out
7/16/2023 12:26:12 AM • Rheem Water... • Answered on Jul 16, 2023
0helpful
1answer

Rheem furnace error code 68

Rheem furnace error code 68 is a mechanical relay system which signals the blower motor to stop because it has not received a signal from the thermocouple. Jul 20, 2022

Rheem furnace error code 68 - HVAC Contractors

Motor Power And Communications Issues (Fault Code "68")

ManualsLib https://www.manualslib.com > Rheem-96v-Series Motor Power And Communications Issues (Fault Code "68"); Line Voltage And Low Voltage Connections To The Communicating Motor - Illustrations - Rheem 96V Series ... ..
4/12/2023 6:20:04 PM • Rheem Water... • Answered on Apr 12, 2023
0helpful
1answer

I have a Rheem RRNL-B030JK08E heat and A/C Unit IM LOOKING FOR THE BURNER COVER PLATE

The burner cover plate for your Rheem RRNL-B030JK08E unit can be obtained from an authorized Rheem dealer or distributor. You can visit the Rheem website to locate a dealer or distributor in your area. Alternatively, you can contact Rheem customer service for assistance in obtaining the burner cover plate. Be sure to have the model and serial number of your unit available when contacting Rheem customer service.
2/23/2023 2:24:37 PM • Rheem Water... • Answered on Feb 23, 2023
0helpful
1answer

I have a Rheem RHIN-CHL25P The error code 160 keeps coming on. Do you know what the problem is? This is a new unit.

this from Rheem error codes Error Code 60 FAULT = Hot Water Temperature Abnormality
  1. Press the Power button to clear the Error Code. If Error happens again:
  2. Ensure water heater inlet and outlets are open and water is supplied to the water heater.
  3. If Error happens again:
  4. Ensure water heater inlet and outlets are open and water is supplied to the water heater.
  5. Check the pump operation.
  6. If it doesn't work, ensure wiring connections to pump.
  7. If even supply power to pump and doesn't run it, replace the pump.
  8. If Error happens again:
  9. Verify recirculation loop length is within specification. Air purge is not enough.
  10. Too much restriction on recirculation loop.
  11. Return loops are clogged.
  12. Check the recirculation loop condition.
1/29/2023 7:37:08 PM • Rheem Water... • Answered on Jan 29, 2023
0helpful
3answers
0helpful
1answer

Rheem furnace error code 68 fix?

Hi, From what I'm seeing this means that there is a bad part within your furnace and it needs to be replaced. It might be the thermostat. You might need to reach out to a local HVAC company to diagnose the issue in person. Thank you.
10/12/2022 12:09:52 AM • Rheem Water... • Answered on Oct 12, 2022
0helpful
2answers

Anode rod location in Rheem power direct vent 50 US gallon water heater

https://www.youtube.com/watch?v=u6w88TXMbg8
9/12/2022 6:41:14 AM • Rheem Water... • Answered on Sep 12, 2022
0helpful
2answers

Rheem Failed Ignition lockout

the gas valve can be replaced, but you will have to pay for installation. this is not a DIY. You can throw money and parts at it. Personally I've replaced my water heater at the first sign of problems. Are they inexpensive no If you furnish model number I can look further.
6/22/2022 6:52:00 AM • Rheem Water... • Answered on Jun 22, 2022
0helpful
3answers

My new Rheem 27 tankless hot water system is not hot

if system is new call whomever installed it and it repaired under warranty. there are several reasons unit is not producing hot water. First thing I would check is temp setting. Again call for service under warranty.
6/9/2022 4:09:22 AM • Rheem Water... • Answered on Jun 09, 2022
Not finding what you are looking for?
Rheem Direct Vent Natural Gas Tankless Water Heater For 1-2 Bathroom Homes Logo

5 questions posted

Ask a Question

Usually answered in minutes!

Top Rheem Water Heaters Experts

Mike Cairns
Mike Cairns

Level 3 Expert

3054 Answers

Brad Brown

Level 3 Expert

19187 Answers

Sean Wright
Sean Wright

Level 3 Expert

2045 Answers

Are you a Rheem Water Heater Expert? Answer questions, earn points and help others

Answer questions