...model 580 -54501 it will not stay on. goes on but flashes 01 on the screen. For sure this is an error and could be a fault in the heater panel or the motor drive. Must remove out and check if the ...
...or a small fee. Also have your model# and Serial# ready which you should find on the dehum. behind the holding tank. that might be the wrong model # the first 3 digits should be 580._ _ _ _ _ _ _
...model #580-54501700 runs but no water comes out. Do not hear compressor run. Unit powers up and fan runs. these units are notorious for losing their refrigerant charge,if the compressor isn't running ...
...model # 580 543 51500 you may have a stripped out fan unit, the fan motor runs, but the fan does not spin? my fan was plastic and stripped out there should be a flat spot the lines up with shafton ...
...model 580-54701700 that ices up I have a tec checking it out he thinks its a sensor that controls the gas valve that defrosts the coil but he is not sure he ohmed the sensor and its 6 ohms and only ...
model 580 53701300 gets electricity, but will not turn on. The filter seems clean and what's behind it looks clean, too. I'm assuming the that you determined the unit is getting power, because
model 580-54701400 has the same problem. 01 code in the humidity % setting, and it will not reset. Bucket Full light blinks. Had to clean water drain last week, because it was leaking. Any suggections