Getting no fuel to the motor
Check in fuse box for blown fuse and if not blown could be relay which would be located under the hood usually on drivers side in a black box with cover on it. remove cover and there should be diagram inside as to the location of relay in box..If the relay and fuse check out ok then have pressure test prefomed on fuel system....But easyest way is simply turn key to start position but do not start. If fuel pump is working you should hear a humming noise in gas tank area and will only humm for a few seconds. you may want to try this a few time to here it...If you have checked relay fuse and tried this and hear no noise in tank then this would indicate that fuel pump has failed and needs to be replaced...good luck and hope this helps and please rate this post...
No such thing on a GM car.
If the pump is not running you would need to check the fuse and pump relay first.