Culligan Measuring Tools & Sensors - Answered Questions & Fixed Issues

0helpful
1answer

Where do I find a culligan mark 89 bypass valve. My current one is leaking

culligan dealer or look on eBay
6/13/2022 1:11:21 AM • Culligan... • Answered on Jun 13, 2022 • 75 views
0helpful
1answer

My culligan softner mark 89 is stuck in regeneration. i unplugged it & it still regenerates so i bypassed it to make it stop. whenever i try to take it off bypass, it starts regenerating again.

Questions the plastic piece that hits the pin for the main piston does anyone know that part number or name of that piece
6/3/2022 12:50:12 AM • Culligan... • Answered on Jun 03, 2022 • 1,627 views
0helpful
1answer

Culligan water softener Mark 100. C5 code is on. Water softener is not working. What does this code mean?

The main piston is frozen up and needs to be replaced. It gets bent due to poor design. Culligan sells a rebuild kit for this that includes the piston, seal kit, brine refill piston and sleeve along with a new metal bracket to prevent the shaft on the main piston from bending and causing this issue again. There is also a new C clip for the drive gear on top.
11/28/2021 4:48:05 AM • Culligan... • Answered on Nov 28, 2021 • 2,635 views
0helpful
2answers

What is an E3 code on a Culligan Medalist Series?

https://www.manualslib.com/manual/859287/Culligan-Medallist-Series.html?page=8 Quoting from link to free manual shown: FAILURE MODE There are certain conditions that can be interpreted by the circuit board as a failure of the drive motor or motor position switch. Upon failure detection the control will cease further operation. A telephone hand set symbol will be shown in the upper left corner of the display and the error code will be shown. Listed below are the different error codes. 1. Motor Always Turning Error code "E1" occurs when the circuit board detects changes in the motor program switch when the motor is not supposed to be turning. The phone icon and "E1" will be lit in the display. 2. Motor Never Turns The Culligan Medallist Series control is equipped to detect no change in the motor position when the motor is supposed to be turning (motor or piston locked in a frozen position). The AccuSoft circuit board will apply power to the motor for 20 seconds. If there is no change in the motor homing or position switch, the control will power down for 1 minute. The circuit board will repeat this procedure two more times in an attempt to remove the obstruction. If no movement has been detected, the control will permanently power down and a phone icon and an "E2" will appear in the display. 3. Homing Error Error code "E3" occurs when the circuit board detects when the control is unexpectedly in the home position. The phone icon and "E3" will be lit in the display. Error Display Cancellation The error code display can be removed by removing the power to the control for 1 minute. After clearing an error condition, the control will default to the factory settings when power is restored.
7/18/2021 2:46:35 PM • Culligan... • Answered on Jul 18, 2021 • 8,867 views
0helpful
1answer

How do I shut off the water to my Culligan Mark 89 Water Softener without shutting water off to the entire house?

softener bypass valve culligan mark 89 and 812-31xxxdtxegiqlpz1wrurhk2e-3-0.jpg Press the bypass valve piston (sideways) to bypass.
8/15/2019 2:17:46 AM • Culligan... • Answered on Aug 15, 2019 • 511 views
0helpful
1answer

Where can i buy the Culligan-kit 01016267 please? for model culligan Medallist

Try a Culligan outlet, they should be able to help you.
6/2/2019 11:50:33 PM • Culligan... • Answered on Jun 02, 2019 • 604 views
0helpful
1answer

I have the E3 error on my culligan medallion series water softener. I unplugged it and reset it but the next morning it had the same error.

I think you need to replace some parts with the Culligan-set 01016267 . I did have the same problem and after it was replaced everything went just as normal.
3/1/2019 9:37:58 AM • Culligan... • Answered on Mar 01, 2019 • 4,700 views
0helpful
2answers

How do you change the filter to a culligan water

Here are instruction to remove the filter housing. This is from my tips posting. Culligan filter housings are just Pentek/Pentair water filter housings and these tips apply to virtually any filter housing. Frequently whole house filters can be very difficult to remove. The canisters become almost impossible to loosen, even after pressing the pressure relief valve and using a housing wrench. The most common reasons for this are the housing was put back on with the housing wrench, debris in the housing threads and a bad pressure relief valve.h2oservices.jpgl76w9ont156vs3p099e2rqu+8nt56e+fbm9ldnps+cnj57dmpqamzqoj3nqs4doe4cr7sqwf8acoamtivyaikaaaaasuvork5cyii=How to remove a stuck filter housing.1. Turn off the incoming water. 2. By-Pass the Softener3. Go to the nearest cold water faucet, open it and let the water run until pressure drops significantly.4. Turn the water off at outlet of filter (If housing has shutoff on top off head, turn this off now).5. Press and hold the pressure relief button to relieve pressure further.6. Use filter wrench to unscrew housing (If it still won't loosen repeat steps 2-5).7. After removing, clean housing thoroughly, make sure threads are clean on filter bowl and housing head. Lubricate threads of housing and head with plumbers faucet lube or silicone. 8. Clean and lubricate the O-Ring (replace the O-ring every couple years or if housing leaks after screwing back on). It helps to flip the O-Ring over a couple times per year. 9. Replace the cartridge filter and screw the housing back on. 10. Turn the incoming water on slowly while holding the pressure relief button down until all air is purged.11. Open outlet and let water run to cold water faucet until all air is purged.12. Put softener back in service.IMPORTANT! Only tighten the filter housing by HAND! NEVER use the housing wrench to tighten the housing. I hope these tips help you with the angst of removing stubborn filter housings.RJ
7/10/2018 7:21:01 PM • Culligan... • Answered on Jul 10, 2018 • 1,375 views
0helpful
1answer

Culligan water softener mark 89 model 3526-82,3526-83. unit doesn't seem to be drawing brine during regeneration

Either the electric valve has failed, or the line is plugged. Try blowing out the water line first and free it up from buildup and then if it seems unobstructed, check the valve function. Salt crystal buildup is common.
2/3/2018 9:08:59 PM • Culligan... • Answered on Feb 03, 2018 • 1,270 views
0helpful
1answer

Can I get parts for a culligan super s water conditioner

Try go ogling it
1/5/2018 2:59:58 AM • Culligan... • Answered on Jan 05, 2018 • 818 views
0helpful
1answer

How often should my softener regenerate

the regeneration period is set on the water consumption after a set amount of water is used , it should regenerate automatically use quality water filters prior to the softener to remove mud and particles that all affect the regeneration process regeneration is the process of removing the elements that have been collected in the machine and to replenish the salt content in use
9/7/2017 11:38:14 PM • Culligan... • Answered on Sep 07, 2017 • 663 views
0helpful
1answer

How to. Bypass water conditioner of Culligan Estate 2

At the top of the conditioner, there is a tube running across the back of the head near the water line connections. the tube has push knobs on each end. With the blue knob pushed fully inward (knob up against the barrel of the valve / tube), water is routed through the water conditioner where it is softened. Water may be bypassed around the conditioner by pushing the red knob fully inward. Avoid "slapping" the valve when shifting from one position to another. see manual here: https://www.culliganmidmissouri.com/wp-content/uploads/2010/05/Estate2-Softener-Operating.pdf
8/23/2017 6:20:56 AM • Culligan... • Answered on Aug 23, 2017 • 851 views
0helpful
1answer

Error Code e3 on the medalist plus series

Call Culligan on this problem.
12/29/2016 5:54:31 PM • Culligan... • Answered on Dec 29, 2016 • 2,792 views
0helpful
1answer

. My Culligan water softener stopped softening water so I tried to manually regenerate it by turning the knob as it says but it still won't turn on.

Culligan is offering a special on water softener tuneups. Call your local dealer and request a service.
3/7/2015 6:00:59 AM • Culligan... • Answered on Mar 07, 2015 • 848 views
0helpful
1answer

Culligan Mark 100 Had code C5 Doe not work. What does code C5 mean?

A lot of people mistake the "S" as a 5. The error dispaly says "CS" which means call service. You probably have a gasket hung up and need a new seal pack.
3/4/2015 11:23:16 PM • Culligan... • Answered on Mar 04, 2015 • 2,100 views
0helpful
1answer

Water softener is inoperative and is displaying E1

Usually, an E1 error code means the circuit board is bad. Try unplugging the unit for 5 minutes. Upon plugging it back in, if it does not reset itself, that means you need a new board. It is really easy to replace ( just a few wires) and will cost around $160.
11/19/2014 12:19:17 AM • Culligan... • Answered on Nov 19, 2014 • 10,276 views
0helpful
2answers

I NEED A SERVICE MANUAL FOR MY CULLIGAN WATER

Your best course of action is to contact Culligan here:

http://www.culligan-store.com/contact.asp
5/23/2014 12:58:36 AM • Culligan... • Answered on May 23, 2014 • 1,947 views
0helpful
1answer

Won't start after power outage

Most people don't think to plug this type of thing into a surge protected outlet, or surge protector. Probably when the power came on there was a power surge and fried the system. Sometimes homeowners insurance will cover things like that.
3/10/2014 7:04:00 PM • Culligan... • Answered on Mar 10, 2014 • 65 views
Not finding what you are looking for?
Culligan Logo

Ask a Question

Usually answered in minutes!

Top Culligan Measuring Tools & Sensors Experts

Sean Wright
Sean Wright

Level 3 Expert

2045 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66977 Answers

Steve Pack
Steve Pack

Level 3 Expert

7128 Answers

Are you a Culligan Measuring Tool and Sensor Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...