What is the proper setting for the Temp &Humidity?

1 Answer

Anonymous

Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Brigadier General:

An expert that has over 10,000 points.

  • Master 4,736 Answers
  • Posted on Jun 29, 2011
Anonymous
Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Brigadier General:

An expert that has over 10,000 points.

Joined: Jan 15, 2011
Answers
4736
Questions
0
Helped
2105221
Points
14643

Set the temp level at whatever point your home's temperature is now. Lower the humidity level to 35%. If you don't have an LED screen on your unit, set the manual control to maximum.This way, you will extract the maximum amount of humidity and make your home more comfortable.

Hope this helped you. Please let me know. Thanks.

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

, My KM30 Dehumidifier t'stat will not reognise ambient humidity properly. I placed the unit in my boat-steamy 80% humidity at 50%. it consistently turned itself off. Ok on 35 and Lo.

there is a sensor in the unit much like a temp sensor, (bullet shape) over time these do ware out and need to be replaced this tell the unit the temp so the unit knows humidity. it could also just need cleaning as a build up of damp then dry dust can cover the sensor.
0helpful
1answer

Why has it stopped running, but still shows temp and humidity?

I may have reached the humidity level that you have set it at. Press the HUMIDITY button until it says "Lo". That should put you into continuous run mode.
Good Luck.
0helpful
1answer

Doesnt seem to be working and the code CH appears on the display. Fan turns on but not collecting water and its very humid/damp in the basement so its not the humidity setting.

There are 5 basic, yet solvable reason for what you described. Please pay particular attention to numbers 1 & 2..

1. The humidity extraction level is set to HIGH. Lower it to 32-35%.
.
2. Air intake filter is dirty or clogged. Turn unit OFF, & Unplug the
Unit, before removing to inspect & clean it, if necessary. If washed,
allow filter to completely dry before reinstalling. DO NOT operate
the unit without the filter.

3. Obstructed air flow. Maintain a minimum of 12 to 18" of clear air
space around the entire unit.

4. Cooling coils are dirty and need to be cleaned. Use warm water & dish washing liquid to
clean the coils. Rinse and wipe dry. Apply a light coating of WD40 to the coils.

5. Ambient air temperature at floor level is between 40 - 65 degrees.
dehumidifiers do not work well between those temperatures
(Unless, you have a Low Temp Unit*). This applies mainly to
where the air temperature at floor level is colder than at shoulder level
in basement applications. Raising the unit up off the floor,
onto a sturdy table, counter top, etc, that can handle the weight
of the unit, plus a full tank of water, will usually resolve this
problem.

* Your unit is not a low temp model.

If none of the above solves the problem, it may be a case of the compressor needs to be recharged with refrigerant gas or that the humidity condenser sensor has failed. These things usually occur in units that are 5 years old or older. It's rare in a unit younger than that. But, it can happen.

Hope this helped you to troubleshoot and solve the problem, as your model has been discontinued by LG. Thanks for choosing FixYa.
0helpful
1answer

BHD-651D purchased 9-9-08 Ice builds up on coils. Filter and coils/fins clean. Air temp 72 F

What is your humidistat set at? Could you be trying to get to too low a humidity? Try to determine what the humidity is and set the stat just below that. In that way, once it reaches the setpoint, it will cycle off, allowing the coils to warm up.
If that works, lower the setting a bit more & see results.
Write back.

Gary
2helpful
1answer

What is the proper setting for Danby R410A?

R410A is refrigerant gas. I think you wanted to know, what humidity extraction level the controls should be set on. If it is really hot and humid in your area, set the humidity extraction level between 35 & 40%. If you have a mechanical control, turn the knob to Maximum.

Hope this helped you, Bradleyjo. Thanks for choosing FixYa.
0helpful
1answer

My Maytag dehumidifier is on for about a week and very little water gets out of the hose. The humidity rate does not go down. What is the probleme please? Thanks Bernard Parent

There are 5 basic, but solvable reason for what you described. Please pay particular attention to numbers 1 & 2.

1. The humidity extraction level is set to HIGH. Lower it to 32-35%. If you have a Manual Control
Unit, set the humidity extraction knob to Maximum.

2. Air intake filter is dirty or clogged. Turn unit OFF, & Unplug the
Unit, before removing to inspect & clean it, if necessary. If washed,
allow filter to completely dry before reinstalling. DO NOT operate
the unit without the filter.

3. Obstructed air flow. Maintain a minimum of 12 to 18" of clear air
space around the entire unit.

4. Cooling coils are dirty and need to be cleaned. Use warm water & dish washing liquid to
clean the coils. Rinse and wipe dry. Apply a light coating of WD40 to the coils.

5. Ambient air temperature at floor level is between 40 - 60 degrees.
dehumidifiers do not work well between those temperatures
(Unless, you have a Low Temp Unit). This applies mainly to
where the air temperature at floor level is colder than at shoulder
level,
in basement applications. Raising the unit up off the floor,
onto a sturdy table, counter top, etc, that can handle the weight
of the unit, plus a full tank of water, will usually resolve this
problem.

If none of the above solves the problem, it may be a case of the compressor needs to be recharged with refrigerant gas or that the humidity condenser sensor has failed. These things usually occur in units that are 5 years old or older. It's rare in a unit younger than that. But, it can happen.

Hope this helped you to troubleshoot and solve the problem. Please let me know. Thanks.
1helpful
1answer

I was just given a DD50PC as a gift from a friend who did not have the accompanying instruction booklet. He told me to turn the unit on and let it work. I do not know what temp to set it at. It has to...

On a dehumidifer, you set the relative humidity, not temperature. Normally the humidity should be set within 40 to 60 percent humidity.

Click on this link for a copy of the manual for your machine. www.sylvane.com/images/.../delonghi-dd50p-dehumidifier-user-manual.pdf

Hope this helps you.
0helpful
1answer

New unit, try using in basement. nothing happen, should humidity settings be high or low? Dose humidity level be high? In the bucket whats the plastic cup about? do something alow water to enter bucket?

If you trying to remove humidity, the setting or percentage of humidity to you want to remove should be set low. it's actually the humidity that will be left in the air. In the Hot Summer months, you want lower humidity, as opposed to the Winter months, when you want higher humidity.

"Plastic cup inside the bucket" - that's got me stumped. But, I suspect, it may be a float valve to turn the unit off, once the bucket reaches the full level. The water enters the bucket through a drain tube or hole from inside the dehumidifier, above the bucket.

By best advice, since this is a new unit, that you recently purchased, is read the Owners Manual/User Guide and become thoroughly familiar with the proper operation of your Dehumidifier, as well as how to properly maintain it. As, they aren't maintenance free.
0helpful
1answer

My dehumidifier is not working properly. I do not know how it works, I do not have the manual. I have a temperaturesetting and a humidity level area. Do I need to set it on the humidity level to pull water...

Yes set unit humidity dial about half way or until it comes on. You need something to measure humidity. most of dials dont have a humidity reading. Set at about 50% Rus
Not finding what you are looking for?

327 views

Ask a Question

Usually answered in minutes!

Top Fedders Dehumidifiers Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Brad Brown

Level 3 Expert

19187 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66977 Answers

Are you a Fedders Dehumidifier Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...