I just bought the HM500TG small unit, followed the instructions but no mist is coming out. The power light is, I turned the knob to the right but nothing still happens .

2 Related Answers

A

Anonymous

  • Posted on Oct 27, 2010

SOURCE: Just purchased a Holmes Hm495

Fill the tank up with cold water and turn up the volume control. Look for a clogged up nozzle on mister. Click on the link below to download and view the Holmes HM495C-UC user guide:

http://www.holmesproducts.com/ProductDetails.aspx?pid=1443

Ad

Anonymous

  • 4736 Answers
  • Posted on May 06, 2011

SOURCE: My unit is not producing

If the instructions didn't mention how to clean the unit of scale and mineral deposits, that's more than likely the problem.

If that's the case, here's what you need to do: Empty the tank of any more that's still in it and mix a 50/50 solution of White Vinegar and Bottled Distilled Water. Fill the tank with the solution and allow it to set 8 hours or over night. Then tunr the unit on and place your hand in front of the mist nozzle, to see if it's producing mist. If it is, let it run for at least 45 minutes and turn the unit OFF. Empty the remaining solution and refill the tank with Bottled Distilled Water. Run the unit until the tank is 1/2 empty and refill with more of the Bottled Distilled Water. Now, you're set to go. In the future, I'd recommend that you always use Bottled Distilled Water rather than tap water. As it's mineral and scale free.

Hope this helps to solve the problem. Please let me know. Thanks.

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Mainstays Cool Mist Humidifier 1 gal MDH-0103JW Low Tank Indicator Auto Off NEW Manual

Here are the instructions for the Mainstays Cool Mist Humidifier 1 gal MDH-0103JW:
  1. Remove the water tank by lifting it straight up and off the base.
  2. Turn the water tank over and remove the tank cap by turning it counterclockwise.
  3. Fill the tank with cool water and replace the cap by turning it clockwise.
  4. Place the tank back onto the base, making sure it is seated securely.
  5. Plug the humidifier into an electrical outlet.
  6. Press the power button to turn on the humidifier. The power light will illuminate.
  7. Press the mist button to select the desired mist output level.
  8. The humidifier will automatically shut off when the water level in the tank is low.
  9. To refill the tank, repeat steps 1-4.
Note: For optimal performance, it is recommended to clean the humidifier weekly. Please refer to the user manual for detailed cleaning instructions.
Nov 06, 2022 • Humidifiers
0helpful
1answer

Venta Sonic VS205 Humidifier turns and has the green light, makes a buzzing sound, but no mist is coming out.

If you see mist in unit and not coming out fan motor in base of unit bad. Four screws in base and fan unplugs
1helpful
1answer

I turn the humidifier on l or ll. The light is grean but it is not releasing steam or anything. I don't hear a noise and the water level stays the same.

The humidifier may be clogged with a calcium scale build up. Especially, if you use well water or your municipal water supply has a high chemical content.

To solve this problem do the following. Mix a 50/50 solution of White Vinegar and Bottled Distilled Water (enough to fill the tank). Empty any water that is currently in the tank and fill it with the 50/50 solution. Allow at least one hour, before turning the unit ON. After turning it ON place you hand in front of the mist nozzle to see if any mist is being generated. If it's generating mist, allow it to run until the tank is 3/4's empty. Then turn the unit OFF, unplug it and empty the remaining solution. Refill with Bottled Distilled Water and run until the tank is empty.

If the unit did not produce mist after one hour of soaking, allow it to set over night and then follow the procedure above. Generally, an overnight soaking will do the trick. In the future, I recommend using Bottle Distilled Water rather than your tap water.

Hope this helps you solve the problem. Please let me know. Thanks.
0helpful
1answer

I bought the humidifier and my daughter switched the knob to reset now the know will not move off reset. How do i fix this?

Turn the Master ON/OFF Switch to OFF and unplug the unit for 10 minutes. Plug the unit back in, turn the Master ON/OFF Switch to ON and if the unit reset itself like it should have, it should function properly.

Hope this helped to solve the problem. Please let me know. And Happy upcoming Mother's Day!
0helpful
1answer

I have an HM 495, the past 4 days it has been working fine. Now there is no mist coming out and it seems to be spilling water out of the back of the base. What is the problem? I have not been using warm or...

When this happened to me, I took the tank into the bathroom to look at the bottom and then I tried to turn the knob and it wasn't all the way tight. After I tightened it, I put it back on the base and the mist started right away.
0helpful
2answers

Venta 205 no mist

Throw the unit out - it's garbage
6helpful
1answer

Humidifier not working

Ensure there is water in the tank.
  • This may be caused by mineral deposits in the water channels. Try the following: Clean the water tank, base and vapor nozzel with a damp cloth to remove any build up in the water channel.
  • When was the last time the cartridge was changed. (If it’s been over 3 months, this could be the reason why the unit is not working properly.)
  • Unscrew the demineralization cartridge and run the unit, if it starts to mist then you need a new cartridge. (insert cartridge link here)
  • The screw cap for the water tank, onto which one first screws in the demineralization cartridge, has a small rubber gasket. make sure that gasket is not too far down against the outer screw cap. If it is the spring loaded button would not work properly to let the water descend into the base tank .
    The solution: push up on that small rubber gasket so that it is as far up and away from the screw cap as it can be without falling off, and voila! you get mist!!
  • If you have changed the filter recently then take out the cartridge and run the unit without the cartridge for about 15 to 20 minutes.
0helpful
2answers

HM5081TG Reset Light won't turn off

Reset the unit once it is refilled by pushing the power button and holding it down for 5 seconds before releasing. This should reset your unit to factory settings.
Not finding what you are looking for?

295 views

Ask a Question

Usually answered in minutes!

Top Holmes Products Humidifiers Experts

Paul Carew

Level 3 Expert

3808 Answers

Brad Brown

Level 3 Expert

19187 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66980 Answers

Are you a Holmes Products Humidifier Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...