LG LHD45EL Dehumidifier Questions & Answers
Code (CH) (01) on front panel, what does it mean?
I believe it is a water tank code. Re-seat the tank, unplug wait 15 seconds and replug the power cord and see if this resolves the error.
Background relating to other possibilities.
When the water bucket reaches its capacity, the bucket switch opens to shut off the dehumidifier. If the bucket switch fails while it is open, it will prevent the dehumidifier from running. To determine if the bucket switch is defective, use a multimeter to test it for continuity. If the bucket switch does not have continuity, replace it.
9/17/2017 12:24:03 PM •
LG LHD45EL...
•
3,369 views • 0 helpful votes
No water collects in our LG LHD45ELY7
It can be recharged but you would first have to locate and fix the leak and then refill. Then add a schraeder valve and refill at the port till suction line is cold to touch and starts to sweat. That's it!
9/9/2017 1:00:07 PM •
LG LHD45EL...
•
793 views • 0 helpful votes
My LHD45ELT8 LG humidifier does not keep up with
A dehumidifier works like a low powered air conditioner where a fan draws air through a refrigeration unit which cools it and condenses water vapour and collects it in a container.
There is likely to be at least one air filter so some cleaning of the air takes place and such filter(s) will need attention periodically and in addition most manufacturers claim their products need servicing every 3 years.
Best results will be obtained when the room is closed and ventilation minimal and the capacity of the machine is more than adequate for the space where it is sited. A room with an open window or where the door is opened frequently is not really a suitable site for a dehumidifier.
It is important to choose a machine that is somewhat too large as efficiency will fall between service intervals.
It is quite possible a manual for a different but similar model by the same manufacturer will provide some useful information...
6/18/2017 2:57:02 PM •
LG LHD45EL...
•
922 views • 0 helpful votes
How does it work what do I do to operate it
Read the instruction manual and then after you understand that turn it on and set it accordingly. 35% for the humiodity might be a good starting pint.
It has a refrigeration system that blows room air across the evaporator coil then across the condenser coil. The evaporate coil gets cold causing moisture to condense and eventually drip into a collection device.
3/19/2014 6:08:53 PM •
LG LHD45EL...
•
76 views • 0 helpful votes
How to change/ add refrigerant
call A&E FACTORY SERVICE at
1-800-862-9226 do not try to do it your self you need is a factory trained technicians not like your self
1/12/2013 7:02:35 PM •
LG LHD45EL...
•
47 views • 0 helpful votes
My LHD45ELY7 freezes up. Why? Is it broken?
Assuming this isn't just a weather change, it probably needs cleaning. The unit is supposed to run the fan without the compressor intermittently to give the cold coils a chance to warm up a bit so the little bit of ice that normally forms can melt off. But once they get dirty, this melting and runoff is impeded. Spray some formula 409 (or similar) on the coils and rinse thoroughly. It is also possible that the unit is not switching over to run the fan only (without the compressor). This could be due to a bad temperature sensor, or it may be dirty or corroded so it thiinks the coils are a bit warmer than they really are. If you can find this sensor (it's usually attached to the coils with a little spring clip) see if you can't clean up where it makes metal contact (thermal contact) witht the coil. Good luck.
10/14/2012 9:50:54 PM •
LG LHD45EL...
•
318 views • 0 helpful votes
I have a code on
CH 01 Indicates that water collection tank is full and needs to be removed & emptied. Turn the unit OFF and unplug it, before removing the bucket.
9/21/2011 12:03:32 AM •
LG LHD45EL...
•
2,169 views • 1 helpful votes
How do i make it
Attach a length of garden hose no longer than 5 feet, to the threaded drain hose connection that was supplied with your unit, to carry water to the drain.
1. Remove the drain-hole cover on the back left side of your unit.
2. Connect a garden hose to the threaded drain hose connector.
3. Push hose connector tightly to the drain-hole on Rear Grille with the arrow on the tab pointing UP.
The hose attachment will accept a standard garden hose fitting.
Do not over tighten the hose when connecting it to the hose connector,
use a rubber washer and tighten by hand firmly without stripping the
plastic threads.
When being attached to hose connector drain hose connection,
do not bend or kink the hose. The hose should lie flat from the
dehumidifier to the drain.
7/4/2011 2:04:49 AM •
LG LHD45EL...
•
4,512 views • 1 helpful votes
The nmachine works fine but
The bin or bucket as it's called, simply pulls straight out from the holder. Be sure no packing or shipping tape is still on the unit, holding the bucket in place. Be sure when you're trying to remove the bucket, that you pull evenly from left to right on the bucket.
Hope this helps and thanks for choosing FixYa.
9/23/2011 4:46:33 PM •
LG LHD45EL...
•
402 views • 2 helpful votes
Code on the dehumidifier flashes the code "CH
Hi
CH 01 Error means that the temperature sensor/bucket switch
is bad and should be replaced, replacing it yourself will cost you around $30
& 2 hours of your precious time J. Hope this
helps...please post back for further assistance.
Daniel
9/5/2011 11:39:51 PM •
LG LHD45EL...
•
581 views • 0 helpful votes