Top 20 Pitco Frialator SG14 Deep Fryer Questions & Answers

0helpful
2answers

Pilot ignition continuous spark

Sounds like thermostat or no fuel. Gas lines on? Correct orifice for the type of gas youre using?
5/15/2016 5:08:55 AM • Pitco Frialator... • 487 views • 0 helpful votes
0helpful
1answer

Pitco fryer sg14

Sounds like propane. Please is heavier than air. Try opening air shutters on burners.
6/21/2015 11:34:26 AM • Pitco Frialator... • 551 views • 0 helpful votes
0helpful
1answer

My pitco fryer will not ignite unless I tap on the gas control valve knob.

loose thermocouple connection at valve.
7/17/2014 7:21:38 PM • Pitco Frialator... • 1,616 views • 0 helpful votes
0helpful
1answer

Fryer troubleshooting

Hi there, Fryer's Digital Controller will display "BOIL" if the temperature is it reading does not exceed 212F or 100C for quite some time. Make sure that there is enough level of oil (not water) in the Fry Pot before turning it on.
8/19/2014 7:14:10 PM • Pitco Frialator... • 344 views • 0 helpful votes
0helpful
1answer

Why wont the unit light? pilot is working fine

first be sure the valve is in the on position. sounds crazy but I've been there. Next even though the pilot is lit it may not be burning hot enough to make the Thermo pile produce the 750 millivolts the valve needs to operate. If the thermo pile is producing the proper current then the gas valve itself is the culprit. If you are not comfortable with gas and do have the proper testers You should call a pro. The pilot is easy to clean though. turn the gas valve to the off position and remove the pilot. When you remove the gas line to the pilot there is a small oriface inside that looks like a little thimble. Remove it and clean it. the gas flows through a very small hole that clogs very easy. Reassmble it tighten the gas line. Check for leaks with some bubbles and give it a try.
6/5/2014 11:51:54 PM • Pitco Frialator... • 163 views • 0 helpful votes
0helpful
1answer

Hamilton Beach Triple Head 940 Milkshake Mixer stop working

Sounds crazy but check for power at the outlet. If that's good then possibly a bad cord,Power switch or interlock safety switch if it has one. Do you hear a humming sound when you try to use it? If so the motor is frozen up. Hope this helps.
5/24/2014 3:23:28 PM • Pitco Frialator... • 154 views • 0 helpful votes
0helpful
1answer

Flames cominhg out of flue

Hi I use to repair every kind of restaurant equipment under the sun..maybe I can help...Is this a new install of the fryer and it never did this before, or did this just start do this..If a new install, the first thing I would check is the gas regulator and see if it is for Nat gas or Lp gas, and find that out..cause it has to match what you have, comming into the building..usuall the gas valve has a sticker on it that says what the water columbs are like for Nat it is like 3-6, and for Lp(propane) it is like 5-12. Ive seen customers buy a used fryer, and install a LP fryer in a Natural gas build, and the valve lets too much gas to the burners, and it will shoot flames out the top..then you would have to buy and convert a gas valve, or use parts to convert it..let me know further..
4/20/2014 6:41:39 PM • Pitco Frialator... • 265 views • 0 helpful votes
0helpful
1answer

Flames coming out of flue

I am not familiar with this unit but I would highly recommend you get a service tec, it sounds like the gas pressure is to high and this would be an extreme fire hazard. I would highly recommend not using it until it is repaired.
4/20/2014 6:36:23 PM • Pitco Frialator... • 116 views • 0 helpful votes
0helpful
1answer

What is the purpose of fryer filter powder

THE POWDER HELPS TO COLLECT THE PARTICLES IN THE GREASE TO HELP IT SINK TO THE BOTTOM OF THE FLITER SYSTEM FOR EASIER REMOVALE
1/27/2014 2:34:31 AM • Pitco Frialator... • 126 views • 0 helpful votes
0helpful
1answer

The front drain is leaking

Hi there. Check first if there are no foreign objects hangings on the ball causing leak. If you really need to change the ball valve, cling the jaw of a 14-inch pipe wrench on the neck of the valve connected to the fryer drain and turn it counter clockwise (***do this with no oil on fry tank and make sure that the tank is cold). Wrap a teflon tape on the thread before installing the new ball valve. Regards.
7/21/2013 1:19:36 AM • Pitco Frialator... • 677 views • 0 helpful votes
1helpful
1answer

Pitco frialator excessive pilot flame

If you didn't figure it out already you lost the orifice on the pilot light. It's a little metal cup with a tiny hole in it that slips over the end of the gas tube in the pilot assembly. The orifice controls the size of the pilot light. Need to get a new one or find the lost part.
10/11/2012 4:44:24 PM • Pitco Frialator... • 485 views • 1 helpful votes
1helpful
2answers

Got a build up of soot want to clean the mechanics/baffels etc got a manual on that

If you have build up of soot you need a service and a gas fitter to do it .
6/15/2012 5:50:02 PM • Pitco Frialator... • 434 views • 1 helpful votes
0helpful
1answer

Drain valve is leaking

drain off oil the clear blockage in valve , try cleaning it with a clean cloth or asoft brush
3/13/2012 11:21:15 PM • Pitco Frialator... • 783 views • 0 helpful votes
0helpful
1answer

My pilot light is going out and its new what can it be

Short pilot could be blocked , thermopile not giving off 600 mille volts ,loose connections on gas valve , or wire loose on overheat, is pilot turned tothe on postion.
5/25/2012 6:56:50 PM • Pitco Frialator... • 56 views • 0 helpful votes
0helpful
1answer

WHEN FRYER HEATS UP THEN IS LOADED TEMP SEEMS TO FALL AND HAS TO BE RESET

If you manually reset by pressing overtemp thermostat, then check your operating thermostat.. maybe over heating.. if so replace thermostat.. if pilot cuts out completely prematurely without reaching set temp then replace overtemp cut out thermostat as it is faulty.Cheers
3/22/2012 8:22:40 PM • Pitco Frialator... • 212 views • 0 helpful votes
0helpful
1answer

Unit over heats burners stay on after turning off

Either thermostat is faulty or combination gas valve is not shutting off. more than likely it will be a problem with the gas valve which is the big aluminium block located toward the floor of the fryer. the " actuator " on the valve is faulty. replace the valveCheers
3/22/2012 8:14:11 PM • Pitco Frialator... • 67 views • 0 helpful votes
1helpful
2answers

Pitco deep fryer flames coming out the fryer

Hi there.
The soot or carbon have probably build up inside the fire tubes, better check and have an authorized service technician clean them.
Make sure that the fryer is receiving the rated gas pressure and correct gas type as stated on the nameplate, this way, carbon or soot formation on fire tubes can be prevented
Regards.
9/12/2011 5:26:56 PM • Pitco Frialator... • 4,148 views • 1 helpful votes
Not finding what you are looking for?
Pitco Frialator SG14 Deep Fryer Logo

Popular Tags

242 questions posted

Ask a Question

Usually answered in minutes!

Top Pitco Frialator Kitchen Appliances - Others Experts

Paul Carew

Level 3 Expert

3808 Answers

Brad Brown

Level 3 Expert

19187 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66980 Answers

Are you a Pitco Frialator Kitchen Appliances - Other Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Pitco Frialator Kitchen Appliances - Others

  • Pitco Frialator Kitchen Appliances - Others

Most Popular Question

pitco gas frialator oil leak in tank

  • Kitchen Appliances - Others
Loading...