Question about Laars Lite 2 Pool Heater 250,000 Btu / Natural Gas
...Pool Heater won39;t start. When turning it on I used to here a a couple of noises, like a tick, tick then it would ignite. I don39;t here those sounds anymore. Gas is on water flow seems normal. ...
Question about Laars Lite 2 Pool Heater 125,000 Btu / Propane Gas
...heater (teledyne-laars). It won't ignite. The electronic ignition clicks normal briefly then clicks quieter until it no longer clicks. Any body have any idea? I have a model ESC 250k propane heater ...
Question about LXI 400 NATURAL GAS POOL HEATER -
heater won39;t start. comes on for about 2 seconds and blows hot air , then clicks off. message says check ignition. It ignites, but won39;t stay lit heater won't start. comes on for about
Question about H Series Pool & Spa Heater 400k Btu Propane Gas Milivolt Ignition H400p1
H400IDL gas pool heater won39;t start shows SF error code ran when closed pool won39;t when opening serial # 30312726 model H400IDL 400,000 BTU check pressure switch
Question about Laars LX Pool Heater / 400,000 BTU / Natural Gas
...pool heater pressure sensor? My heater won39;t ignite and gives a low pressure indicator. check pressure switch to see if voltage both sides if not see if copper tube is plugged make sure filters ...
Question about Minimax Ch 400,000 Btu Propane Pool Heater Millivolt Ignition
...heater is not running and will not run. How do I clear the reading? I39;m assuming it won39;t start because it thinks the water is too hot.? minimax nt 250dv temp reading is 105 but heater is not ...
...the click that let's you know the gas was released, I smell the gas, yet the heater won't catch and fire. Any thoughts? hot surface igniter may not be hot enough to ignite the ...
Question about Laars Lite 2 Pool Heater 400000 BTU Propane Gas (Pilot Light Ignition)
jandy lite 2 pilot won39;t start check fuses that go to ignitor if ok ohm out ignitor when unplugged should be about 78 ohms if shorted or open replace if ok check safety circuit
Question about Hayward H250 250k BTU Millivolt Pool Heater - Propane
pool heater will not light I cleaned the burners, igniter, and flame sensor. The igniter does glow. The fan comes on. Gas flows. The burners will not light. After 3 tries, I get 1F code. Why won39;t
Question about SR400NA Max E Therm Pool Spa Heater Dual Electronic Ignition LoNox 400000 BTU Natural Gas ASME
Heater won39;t ignite and leaking water bad heat exchange probably ruined ignitor