...Motor (M1) Mechanical Control Board (PWB-M) DC Power Supply (PU1) Step Action WIRING DIAGRAM Control Signal Location (Electrical Component) 1 Check the M1 connector for proper connection and correct ...

Ad

Question about bizhub C250 All-In-One Laser Printer

1 Answer

...M1= main motor 1. Does the transport motor (M1) operate during power up? NO, Ensure the connection of the connector (PJ21A) is secure. 2. Replace the transport motor. YES, Check if there is excessive ...

Ad

Question about bizhub C250 All-In-One Laser Printer

2 Answers

...Motor M1 malfunction.Reset Procedure= Turn OFF and ON the power switch.Relevant Electrical components are, Main Motor M1, Printer control board, *PRCB*Power supply unit, ...

Question about bizhub C250 All-In-One Laser Printer

1 Answer

...Motor (M1) Detection is executed every 100 msec after the start of motor rotation; however, the drive detection signal is absent for 2 sec. 1.Replace the Main Motor (M1). 2.Replace the DC Controller ...

Question about bizhub C250 All-In-One Laser Printer

1 Answer

motor (M1) lock signal remains HIGH for a continuous 1-sec. a period at any time 1 sec. after the main motor has started turning. Remedy 1 Check the connector between M1-PRCB CN6 for proper connection

Question about bizhub C250 All-In-One Laser Printer

1 Answer

...motor's failure to turn. 1 Check the M1 connector for proper connection and correct as necessary. 2 Check M1 for proper drive coupling and correct as necessary. 3 Check the PRCB connector for proper ...

Question about bizhub C250 All-In-One Laser Printer

1 Answer

...motor remains stationary. Remedy 1 Check the M1 connector for proper connection and correct as necessary. 2 Check M1 for proper drive coupling and correct as necessary. 3 Check the PRCB connector for ...

Question about bizhub C250 All-In-One Laser Printer

1 Answer

motor (M1) rotates for a given period of time after the position is switched from stand by position at lift-up plate to the feed position. • The bypass lift-up position sensor (PS26) is not turned ON

...M1 motor failed. I removed the M1 motor. Now, can I check if the problem it's 100% the motor or the electric boar Konica Minolta Bizhub C203 / C253 Error code / Trouble code: C-5102 C5102 Replace M1 ...

Question about Bizhub c203 Copier

1 Answer

...motor (M1) lock signal remains HIGH for a continuous 1-sec. period at any time 1 sec. after the main motor has started turning. Causes: Main motor (M1) Printer control board (PRCB) DC power supply ...

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Office Equipment & Supplies Experts

k24674

Level 3 Expert

8093 Answers

Brad Brown

Level 3 Expert

19187 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66980 Answers

Are you an Office Equipment & Supplies Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...