Question about bizhub C250 All-In-One Laser Printer
...Motor (M1) Mechanical Control Board (PWB-M) DC Power Supply (PU1) Step Action WIRING DIAGRAM Control Signal Location (Electrical Component) 1 Check the M1 connector for proper connection and correct ...
Question about bizhub C250 All-In-One Laser Printer
...M1= main motor 1. Does the transport motor (M1) operate during power up? NO, Ensure the connection of the connector (PJ21A) is secure. 2. Replace the transport motor. YES, Check if there is excessive ...
Question about bizhub C250 All-In-One Laser Printer
...Motor M1 malfunction.Reset Procedure= Turn OFF and ON the power switch.Relevant Electrical components are, Main Motor M1, Printer control board, *PRCB*Power supply unit, ...
...Motor (M1) Detection is executed every 100 msec after the start of motor rotation; however, the drive detection signal is absent for 2 sec. 1.Replace the Main Motor (M1). 2.Replace the DC Controller ...
motor (M1) lock signal remains HIGH for a continuous 1-sec. a period at any time 1 sec. after the main motor has started turning. Remedy 1 Check the connector between M1-PRCB CN6 for proper connection
...motor's failure to turn. 1 Check the M1 connector for proper connection and correct as necessary. 2 Check M1 for proper drive coupling and correct as necessary. 3 Check the PRCB connector for proper ...
...motor remains stationary. Remedy 1 Check the M1 connector for proper connection and correct as necessary. 2 Check M1 for proper drive coupling and correct as necessary. 3 Check the PRCB connector for ...
motor (M1) rotates for a given period of time after the position is switched from stand by position at lift-up plate to the feed position. • The bypass lift-up position sensor (PS26) is not turned ON
Question about Bizhub c203 Copier
...M1 motor failed. I removed the M1 motor. Now, can I check if the problem it's 100% the motor or the electric boar Konica Minolta Bizhub C203 / C253 Error code / Trouble code: C-5102 C5102 Replace M1 ...
...motor (M1) lock signal remains HIGH for a continuous 1-sec. period at any time 1 sec. after the main motor has started turning. Causes: Main motor (M1) Printer control board (PRCB) DC power supply ...
Usually answered in minutes!
2,817 Questions
2,244 Questions
2,162 Questions
2,149 Questions
1,912 Questions