Questions & Answers for: corona wire copier kyocera

Corona wire but still no Help. Please Help Minolta D251 Giving error C0F32 i treied everthing changing developer etc but still no Help. check the exp.lamp . it mzay be blinking at the time of scanning

Ad

Question about CS-2550 Black and White Copier

2 Answers

blank copy please check corona wire may be it was broken re-wear it then print ok 1 no coronas in this copier 2 no charge will give u solid black copy check transfer or drum possibly not turning

Ad

Question about FS-C5015N Laser Printer

1 Answer

corona wire/grid with the cleaning block that comes with each toner.ensure that you leave the corona unit as far out of the machine as possible for 30 seconds to allow the grid to dry.If this does not

Question about FS-C5015N Laser Printer

1 Answer

letters longitudinally-kyocera 1530 try cleaning the charge corona wire. It is located above the drum unit and may have a blue handle that you will pull out about 10 inches and push back in. Good luck

...corona wire is used on Kyocera products: FS-9520, KM-4035, KM-3530, and KM-C2520. Is it 60 Micron Oxidized? The service manual does not specify but you will probably be ok with tungsten or oxidized. ...

...it started printing solid black pages You may clear the problem by cleaning the primary corona wire inside the drum unit by sliding the blue tab.Make sure you return the blue tab to the Home

Question about KM-3035 All-In-One Laser Printer

1 Answer

...appeared when copy It sounds as if the Main Corona unit is shorting out. This normally happens when you replace the toner cartridge. Please try cleaning the main corona wire.(instructions in the

Question about Mita Km4530 Km5530 Compatible Copier Toner 370ae011

1 Answer

...corona wire? Also check the drop down mechanism that holds the transfer unis. Mechanichaly if it is not in the correct position when in the locked position this can cause the problem that you are ...

Question about Copystar CS-1820 Black and White Copier

1 Answer

How to change corona wire Copystar copier Incomplete discharge of last image ghosting onto newest image goasting usually is a fuser problem ,needs new fuser part# 302DC93062

Question about KM-5035 Printer

1 Answer

corona wire how is the corona wire supposed to be re-run, some expert took it apart and now I'm trying to put it back together is there any images that I can look at? Take to dealer..

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Office Equipment & Supplies Experts

k24674

Level 3 Expert

8093 Answers

Brad Brown

Level 3 Expert

19187 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66980 Answers

Are you an Office Equipment & Supplies Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...