Actuator motors either get a tear in the rubber or a hose is broken and not letting vacuum assist in its opening.
You can try moving the lever by hand and see if the air gets colder on the bad side.
- If you need clarification, ask it in the comment box above.
- Better answers use proper spelling and grammar.
- Provide details, support with references or personal experience.
Tell us some more! Your answer needs to include more details to help people.You can't post answers that contain an email address.Please enter a valid email address.The email address entered is already associated to an account.Login to postPlease use English characters only.
Tip: The max point reward for answering a question is 15.
eBayhttps://www.ebay.ca > ... > HVAC Vent Actuators
NOS 2004 BUICK CENTURY HEATER BLEND DOOR ACTUATOR 52404369 HVAC ; Breathe easy. Returns accepted. ; Fast and reliable. Ships from United States. ; Condition. New ...
eBayhttps://www.ebay.ca > ... > HVAC Vent Actuators
Dorman 604-107 HVAC Air Door Actuator fits Buick Century · C $42.80 ; 2 Heat Heater A/C Fan Air Vent Blend Door Actuator for Chevy GMC Pickup 15-72971 · C $46.84 ...
Do you know how to do automotive electrical testing ? Have a volt meter ? Know how to use a volt meter ? Videos on youtube .
Air Temperature Actuator
The air temperature actuator is a 3 wire bi-directional electric motor. Ignition 3-voltage, ground and control circuits enable the actuator to operate. The control circuit uses a 0-12 volt linear-ramped signal to command the actuator movement. The 0 and 12-volt control values represent the opposite limits of the actuator range of motion. The values in between 0 and 12 volts correspond to the positions between the limits.
When the HVAC control module sets a commanded, or targeted, value, the control signal sets to a value between 0-12 volts. Actuator shaft rotation is the results of a commanded position input by the vehicle operator. With a new actuator commanded value action, the maintained actuator control value is changed.
Temperature Valve Actuator Replacement - Right Side
Remove the glove box to get at this part to replace !
On this year,it is most likely low on freon,but it could be a actuator motor gone bad.The actuator motor directs temp to that side,but I am thinking,it is just low on freon,if this was helpful,please rate,and thank you.
Actuator motors either get a tear in the rubber or a hose is broken and not letting vacuum assist in its opening.
You can try moving the lever by hand and see if the air gets colder on the bad side.
×