I cannot get my new Flotec 4012-10 well pump to prime or pump water

Even new pumps have faulty parts. It could be that the foot valve is defective.
12/24/2023 2:50:15 PM • Flotec Plumbing • 34 views • 1 helpful votes
0helpful
1answer

I have a Flotec model fp5172. Will this pump automatically shut off when it reaches max pressure?I

No, this pump does not natively turn on and shut off based on pressure. You need to add a pressure switch and tank. Flotec has the manual for the FP5172 here: https://www.pumpagents.com/pdf/FlotecPumps/Flotec-FP5172.pdf . I hope this helps. Cindy Wells
8/31/2023 8:33:26 PM • Flotec Plumbing • 104 views • 0 helpful votes
0helpful
2answers

Why is my submersible well pump kicking on with good pressure for about 1 minute then just stops for about 3 min and kicks back on back and forth.

Might be a bad float switch, bad relay kicking out, or possibly the motor tripping it's thermal protection if it's getting hot.
3/15/2023 10:25:25 PM • Flotec 1 Hp Deep... • 81 views • 0 helpful votes
0helpful
1answer

1hp pump. Why does it start and run 5 seconds then shut off?

Does this unit have a pressure switch? A lot of pressure switches have an adjustable cut-in / cut-out allowing you to change the nominal operating pressure. If it is only running a short time, you could adjust the pressure switch and see if it helps. **With the power off** make small adjustments, don't crank it.
7/14/2021 12:26:08 AM • Flotec Plumbing • 892 views • 0 helpful votes
0helpful
1answer

I cant get my flotec sprinkler pump 5162 to stop leaking between the motor and pump housing i replaced the large o ring

recheck the seal -gasket and housing [crack or warpage]
7/3/2021 10:08:18 PM • Flotec Garden • 80 views • 0 helpful votes
0helpful
2answers

I have an 7yr old 1.5HP Flotec sprinkler pump. it hums but does not start. does it have a starting capacitor that can be replaced.

https://www.pentair.com/en-us/products/residential/water-supply-disposal/water-supply-pumps/pentair-flotec-fp5172-thermoplastic-sprinkler-pump-1-5-hp.html
3/28/2021 2:01:26 PM • Flotec Garden • 496 views • 0 helpful votes
0helpful
1answer

No internal diagram for Flotec E75VLT is shown at Pentair website!

its a motor and a switch what else is there?
1/3/2021 9:31:03 PM • Flotec 3/4 Hp Ci... • 66 views • 0 helpful votes
0helpful
2answers

What is the specification for the capacitor in a Flotec FP5172-08 irrigation/sprinkler pump?

Contact Flotec to inquire.
7/22/2020 12:01:25 AM • Flotec Garden • 280 views • 0 helpful votes
0helpful
1answer

Can I reduce to use a 1" water line on a Flotec pump with a 1-1/4" port?

How to Set the Pressure Regulator on a Deep Well Jet Pump
  1. Install a pressure gauge between the pump and the control valve if one is not already installed. ...
  2. Run the pump until the pressure has stabilized. ...
  3. Adjust the discharge control valve to provide 20-psi back pressure. ...
  4. Open a faucet to let water run near the pump. ...
  5. Open the pump control valve slowly.
https://www.hunker.com/12583591/how-to-set-the-pressure-regulator-on-a-deep-well-jet-pump
5/13/2020 5:14:08 PM • Flotec Plumbing • 262 views • 0 helpful votes
0helpful
1answer

I have a flotec fp5455 need to replace impeller but cant seem to be able to take it off. Any suggestions on how to take it off please

Ohhhh ya. Fun, fun, fun. But, there is a way. Watch this video from Joseph and Robert on the "easy way' to remove a stuck water pump impeller. How To Remove Stubborn Impellers
6/6/2019 12:35:34 AM • Flotec Plumbing • 869 views • 0 helpful votes
0helpful
1answer

Flotec E100ELT 7 yrs. Running continuously. Unplugged. High water alarm on bu no high water. Off x 2d. Pump into new outlet running continuously. Plugged alarm and smoking. New switch?

I would say to replace the switch but if you know how to meter it; that would definitely tell you. Also check for obstructions.
9/18/2018 6:02:37 PM • Flotec Garden • 179 views • 0 helpful votes
0helpful
1answer

Need manual for ACE5S 1/2hp well pump

https://inspectapedia.com/water/Water_Ace_Pump_Manual.pdf Add Comment if this is not the manual. Your question is posed under Flotec Corrosion Resistant Shallow Well Jet Pump, but you requested a manual for ACE51 pump. http://www.wellpumpsystem.com/tags/ace5s/
5/5/2018 3:38:49 PM • Flotec Corrosion... • 678 views • 0 helpful votes
0helpful
1answer
tip

Leaking well pressure tank

This is for tanks that have a bladder inside which holds the water only. The air in the tank is above the bladder and applies pressure to the bladder using the wall of the medal tank as the envelope for the air. Most come pre-charged from the factory. Air and water NEVER mix in there. The valve stem is the entry point for the air is is NOT ATTACHED TO THE BLADDER. I had an air leak somewhere in my tank system. Worst case the bladder was ruptured but I had to check. I had the pump recycle every 3 seconds. I must not have had any pressure in the tank. Checked it and I was right. Re- pressured it at the valve stem on top according to manuals instructions and then waited for a day to see if it held pressure 24 hours. It did not hold, so I got some liquid dish soap and spread some around the valve and it bubbled a lot. NOTE: It could leak from the stem itself which is replaceable ( the un-screw-able cap covering the metal stem inside the rubber tube/stem.) You'll need a tire stem removal tool from Walmart for 50 cents. Usually in a packet with both the tool and a new stem. Looks like a cap with a forked prong on the back side. Mine leaked around the base of the stem where it enters the tank. I went on line to see if there is a remedy and most say no and replace entire tank. These things are hundreds of dollars...all for a $2 valve. So I let all the pressure out of the tank by uncapping the stem tower and released the pressure by pushing down inside on the plunger pin until all pressure is gone...or else the stem will shoot out like a bullet. Then I spread plenty of dish liquid around the hole entry area and gently tilted the stem all around in a circle. Kinda wiggling it in place to loosen up the rust grip. (Don't worry it won't come out. You would have to cut it to get it out. I suppose you probably could crack it if you rotate too extremely.) Use you own judgement here. All you are doing is getting the lube (soap) in the groove around the ring so you can get the rust grip loosened up so you can spin/turn the valve in place to loosen up the rust and gunk keeping it from sealing properly. I took a pair of vice grips and grabbed hold of the area just above the bulge where it comes out of the tank and turned it in place 2-3 rounds. Just enough vice grip to hold tight during the spin and not crush the tower. After the lube works in, it should seem easier to turn. Remember this is after you are ready to replace the tank and last ditch effort. Re-pressure the tank and check for leaks. You don't have to put water back in to test the air pressure. Remember it should be there even without water as from the factory. Air it up and apply soap to test. Mine has been OK for months now. A new bladder is almost as expensive as a new tank so that was a no go. I have located a replacement valve (see below). If you have been around car tubeless tires, this is the same thing on these tanks. They are inserted with a tool and are held in with rubber expanded in the hole rim after insertion. To get these out you have to cut them...that's how much the tool squeezes the rubber and seals the rim. They also can only go in from the under side...that's why these are so hard to do. Anyway, if you want to try even more last effort, you can take the tank out in the yard, and flip it upside down and remove the bladder. Several nuts hold the ring in place which clamps the bladder opening to the water entry point. Take the bladder out and look inside the tank. At the top end is where the valve is. Flip it over and cut the stem out of the hole. Then go to an auto parts store and get a replacement valve which can be inserted from the inside and tightened with a nut on top. Replace the bladder and air it up properly VERY IMPORTANT. I have found this one on Amazon which is a push it through the inside of the hole and do all the tightening from the top side. $8 for 4.

VTR TR-416 1 1/2" Outer Mount Metal Valve Stem (4 Pack)

0helpful
1answer

Pressure fluctuates

There must be a hairline crack to where it is only noticeable when the pump starts to run creating a vacuum.
1/14/2018 10:48:02 PM • Flotec 1 - 1/2... • 117 views • 0 helpful votes
0helpful
2answers

I have had several of

Steaming water as in hot steaming or temperature differential steaming?
12/10/2017 10:21:02 AM • Flotec Automatic... • 93 views • 0 helpful votes
0helpful
1answer

I thought I remembered how to wire a flotec 5182 pump, but obviously not. I put a new impeller kit into it and now it just clicks when I turn it on. The manual and the diagram on the pump are unclear.

try www.freeadjunction.com>wiring>wiring-dia I found that site by going google and typing---schematic diagram for wiring a flotec 5182 pump there are other sites if that is not suitable
11/18/2017 7:36:03 AM • Flotec Pool &... • 130 views • 0 helpful votes
0helpful
1answer

The switch has failed on

Did you note to where the 5 wires were attached to the old switch? Does the switch resemble the other less a terminal? No instructions with the new switch?
11/27/2017 9:24:03 PM • Flotec 1/3... • 94 views • 0 helpful votes
Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Flotec Experts

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

john h

Level 3 Expert

29494 Answers

Paul Katynski
Paul Katynski

Level 3 Expert

575 Answers

Are you a Flotec Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...