Questions & Answers for: Ingersoll Rand change coolant

Question about Stationary Air Cooled Rotary Screw Compressor 10 Hp, 35 Cfm At 125 Psi, Model# Ep

5 Answers

...Need more info. What is the Model. What type of oil (coolant) is being used. Has oil type been changed. Also check the oil cooler and make sure you can see thru it. Also some units will not run ...

Ad

Question about Stationary Air Cooled Rotary Screw Compressor 10 Hp, 35 Cfm At 125 Psi, Model# Ep

1 Answer

...coolant. I changed sparator element. Changed orifices..Had other techs tell me that the sparator element had a slight design change and scavage tube was not hitting the bottom of the element filter. ...

Ad

Question about Stationary Air Cooled Rotary Screw Compressor 10 Hp, 35 Cfm At 125 Psi, Model# Ep

2 Answers

...coolant coming through air filter element? Hi dear, There problem is loan/unload pneumatic valve not work properly. Please change this pneumatic valve. Check inlet valve assembly, defective oring or ...

Question about Compressors 5-HP, 80-Gallon, Triple Stage Rota

1 Answer

...COOLANT change including amount needed. SSR Ultra Coolant (Standard Factory Fill) SSR Ultra Coolant is a polyglycol base coolant. Change Ultra Coolant after every 8000 hours or every two years, ...

...coolant sending unit be bad? well you didnt mention what year or model number you got but some of the better IR compressors have a fuel saver mode that if they don't sense any change in load for like ...

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Ingersoll Rand Tool and Hardware - Other Experts

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66979 Answers

Are you an Ingersoll Rand Tool and Hardware - Other Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...