Anonymous Posted on Jun 14, 2008

Air conditioner won't shut off when temperature reached

Dear sir/madam

all of sudden our central air conditioner won't shut off when temperature reaches. we can't figure out why. we have a programmable thermostat and we changed the batteries today. any advice would be appreciated

  • Anonymous Jun 15, 2008

    thank you Refritech08 for your assistance I have contacted a heating and cooling technicians to look at the air conditioner today.

  • CDDANO Mar 18, 2009

    Change the batteries on thermostat and once temperature was reached it won't turn off







    Jantrol AIr Conditioner

×

2 Answers

Anonymous

Level 1:

An expert who has achieved level 1.

Mayor:

An expert whose answer got voted for 2 times.

  • Contributor 1 Answer
  • Posted on Jul 31, 2010
Anonymous
Contributor
Level 1:

An expert who has achieved level 1.

Mayor:

An expert whose answer got voted for 2 times.

Joined: Apr 06, 2010
Answers
1
Questions
2
Helped
3779
Points
2

Myar conditioner will not shut off. doesnt matter what temp its at it wont turn off..... it cools the house nice but we have to turn it off manually.

Anonymous

Level 2:

An expert who has achieved level 2 by getting 100 points

MVP:

An expert that got 5 achievements.

Governor:

An expert whose answer got voted for 20 times.

Scholar:

An expert who has written 20 answers of more than 400 characters.

  • Expert 149 Answers
  • Posted on Jun 15, 2008
Anonymous
Expert
Level 2:

An expert who has achieved level 2 by getting 100 points

MVP:

An expert that got 5 achievements.

Governor:

An expert whose answer got voted for 20 times.

Scholar:

An expert who has written 20 answers of more than 400 characters.

Joined: Apr 13, 2008
Answers
149
Questions
0
Helped
69173
Points
258

Suspect a stuck contactor on condenser unit or cooling relay stuck

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

My dometic roof air works fine in the daytime but at night it shuts down and try to restart on and on others have said they replaced the stat and still the same problem,any other ideas

Change the automatic temperature detection settings. Many of these Dometic systems have an automatic indoor outdoor temperature gauge that determines when it shuts off. This is separate from the normal thermostat. When the outdoor temperature reaches close to the indoor set temperature the unit shuts off.
0helpful
1answer

Ok, do you run ceiling fan when running central condition, or not,

I do, as I found I can set the thermostat temperature higher, so the sir conditioner can run less.
Plus, the ceiling fan uses less power than the AC.
0helpful
1answer

I HAVE A CARRIER CENTRAL AIR, THE OUTSIDE FAN IS BLOWING INWARD AND WON'T SHUT OFF WHEN THE FURNACE SHUTS OFF AFTER TEMP IS REACHED

Check the t-stat to make sure that the "fan" switch is st to auto. If not the fan is in the "on" position and is always on. Otherwise, It sounds like your "Central Air" is a packaged unit(Furnace and air all one unit outside the home) and the fan relay inside the unit is stuck. This need to be replaced. It is the rectangular unit with the leads from the fan motor attached to it.
0helpful
2answers

The air conditioner cools the room but it shuts of. The power light doesn't come on while unit is on. Can I replace the plug?

"The air conditioner cools the room but it shuts of." -- Temperature reached, but does not turn back on automatically? Stops short of reaching temperature? Shuts off for a period, but will come back on only to shut off again later?
Most importantly, how do you get it to turn on again?
"The power light doesn't come on while unit is on." -- If the unit is on and the power light is not, then the power light must not be operating (is burnt out).
Actual answer: "Can I replace the plug?" -- Of course you can.
What is causing you to feel that the plug needs replaced?
:o).
0helpful
1answer

Thermostat dial broke and huge ice pushed out cover. Fan still works ok.

dear sir

i think in your air conditioner,s thermostat is not working because there huge of ice on unit. thermostat control to compressor for desire temperature, when temreture reach till desire tempreture it,s cut supply for compressor . and make balance on cool air.
please replace thermostat for solve this problem.


hope answer the question
thank you
please vote!
1helpful
1answer

Show me where the filter is located

dear sir /madam
please know what is type your air-con i mean widow type or split type or Central air conditioning's unit .if your air con is window type air conditioner then remove cover (grill) and find there is air filter if your air con split type of then open its cover there down side of cover there.is filter located
if air con is central cooling unit the find out your filter in duct side i mean air blower side where fresh cool air going to your room .

use this method i hope you will find solution of your problems


thank you
please vote!
1helpful
1answer

How do you set the temperature

If you have an air conditioner with a temperature display, use the up or down arrows on the touch pad to change the temperature setting.

However, if you have an air conditioner with only a dial that goes from 1 to 8 (or whatever number), turn the dial up as high as it goes and put the fan speed on high. When the desired comfort level is reached, slowly turn the dial down until the compressor just shuts off. You will be able to hear when this happens.

If the temperature gets a bit too warm turn the dial up in small increments and wait an hour or so to see if your comfort level is reached.
0helpful
2answers

Central air conditioner doesn't turn on... Any suggestions?

If the compressor turns off and won?t come back on during a very hot day, the unit may have built up a high "head" pressure and the high-pressure limit switch may have tripped. This is usually located right inside the access panel on the compressor unit. Simply push the button to return it to operation. If your central air conditioner doesn't go on automatically: 1) Be sure the thermostat is set to "cool" and set below room temperature. 2) A central air conditioner should be on a dedicated 240-volt circuit; check the main electrical panel and any secondary circuit panels for a tripped breaker or blown fuse. If you find the problem here, reset the breaker or replace the fuse. 3) Make sure the furnace power switch is turned on and that the outdoor condenser's power switch, mounted on the outdoor unit, hasn't been shut off. Also be sure the 240-volt disconnect next to the compressor (in a metal box, usually mounted on the house wall) hasn't been shut off. 4) Turn off the power to the air conditioner and check the thermostat. 5) Remove the thermostat's cover and unscrew the wire from the Y terminal. 6) Turn the power back on. 7) Holding the wire by its insulation, touch the bare end to the R terminal and hold it there for about 2 minutes. If the compressor kicks on, the thermostat is faulty; replace it or call an air conditioning technician. If the compressor doesn't go on when you hold the two wires together, turn the power back off and call a service technician.
Not finding what you are looking for?

3,789 views

Ask a Question

Usually answered in minutes!

Top Kenmore Heating & Cooling Experts

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Kenmore Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...