Lazy z spa error e05

You can find almost every error code known out there for hot tubs at the following link: Error Codes Click on that link and then scroll down through them.RodUS Parts Center
2/8/2013 4:28:07 PM • Jacuzzi Pool &... • Answered on Feb 08, 2013
0helpful
1answer

Hi, I have spa form prestige 50 and i cam home from work and it had cut out, I restarted the jacuzzui and it went though the 4 minute prima mode and then cut out again. Please can anyone give me some

it sounds like the heating element is out. Undo the wires going to the heater and then turn the breaker back on. If the heater is bad then it will go through the purge cycle and continue to run but obviously not heat.If this is the case then you need a new Spa Part heating element. On the heater tube is the information you will need in order to find a replacement.RodUS Parts Center
2/8/2013 4:26:06 PM • Jacuzzi Pool &... • Answered on Feb 08, 2013
0helpful
1answer

The hot tub reads - - - and has power but nothing is working.

this problem is over a month old so i am not sure if you still need the help.Start by turning off the breaker. Unplug everything from the hot tub i.e. pump, heater, air blower, light - anything connected to the spa control box.Now turn on the breaker. Check the voltage coming out of the transformer in the spa control box. You may have a bad transformer or a bad circuit board. If you have power coming out of the transformer going into the circuit board, do the following:If it doesn't blow the breaker then systematically do the same process but plug in one item at a time starting with the pump first until you find the problem. RodUS Parts Center
2/8/2013 4:14:27 PM • Jacuzzi Pool &... • Answered on Feb 08, 2013
0helpful
1answer

Need help with Rocoi LDPB-140, 1 HP pump for jetted tub

Rocoi pump i have never heard of and I have been in this business since 1981.Any Mfg Name on there besides that name?
2/1/2013 4:23:43 PM • Jacuzzi Pool &... • Answered on Feb 01, 2013
0helpful
1answer

Jacuzzi hot tub, Water is too hot. Heats until it trips the system. I have replaced the analog temperature control,

1) Safety question firstWhy hasn't the GFCI tripped. If your spa is not protected by ground fault., then you are at serious personal risk.http://waterheatertimer.org/How-to-wire-GFCI.html#arc-fault2) Replace the element.http://waterheatertimer.org/How-to-test-water-heater-element.html3) If element is cracked, it can continue heating to ground wire, causing runaway heating.This applies to spas, and water heaters of all type. If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
12/9/2012 9:42:36 AM • Jacuzzi Pool &... • Answered on Dec 09, 2012
0helpful
1answer

Replaced part but error FLO1 message does not go out

FLO Codes can be a nightmare.What part did you replace? The Pressure switch? If so try adjusting the the pressure switch. These switches typically have a dial on the side or they'll have a spot in the top where a screw driver can be used to adjust the sensitivity. Or:Dirty Filters can cause FLO error, try operate the spa with out the filter cartridge it if works its the filter.Check that all slice valves are completely open & all suction and skimmer lines are clear of debris.Check that pump impeller is working properly. Hope that helps
11/14/2012 10:34:42 PM • Jacuzzi Pool &... • Answered on Nov 14, 2012
0helpful
2answers

We have a 1997 or 1998 beachcomber hot tub,

I have a 1997 beachcomber tub w/ digital 3000 which was locked in economy and temp said 80*. i check solded joints and they were ok, i replaced the main board and it work fine now.
10/10/2012 10:37:20 PM • Jacuzzi Pool &... • Answered on Oct 10, 2012
0answers
0helpful
1answer

Leaky Motor

This sounds like it could be the shaft seals, which is a cheap fix.The Jacuzzi Magnum calls for seal 35-423-1021 You might consider replacing the seal plate O-Ring as well. - 35-105-1120
8/9/2012 9:57:55 PM • Jacuzzi Pool &... • Answered on Aug 09, 2012
0helpful
1answer

How do I remove impellor from a/o smith 7-181327-03 pool pump

If the impeller is fused onto the shaft by rust or mineral build up the chance you will be able to remove it with out destroying it are slim. You're likely going to need a new impeller and shaft seal kit, so I'd suggest getting them before your try to remove the old impeller.First you must remove the water/plumbing and the strainer basket assembly or pump faceplate if applicable to gain access to the impeller.Step two, on the backside of the motor (opposite side of impeller) you will find the back end of the motor shaft. This end of the motor shaft has a slot in it so that you can insert a large flat screw driver. This will help you to hold the shaft while you try and unscrew the impeller. fyi your pump might have a plastic housing on the back of the motor which you should remove to get to the back of the shaft. This is best way to remove the impeller but its likely to be a struggle if there is rust on the shaft. Good Luck
5/29/2012 3:45:56 PM • Jacuzzi Pool &... • Answered on May 29, 2012
0helpful
1answer

How can I unscrew the lid of the Maghum Jacuzzi pump... it is too large for a wrench...

2X2 AND A HAMMER, THE RIBS GIVE YOU JUST ENOUGH SPACE TO TAKE THE WOOD EDGE AND SMACK IT, GO FROM ONE SIDE TO THE OTHER, ONE OR TWO HITS EACH TIME. IT WILL GIVE IN AND LOOSEN .. USE MAGIK LUBE NEXT TIME ON THE THREADS AND O-RING AND YOU WILL NOT HAVE THIS ISSUE AGAIN.. JAY THE POOL PUMP MOTOR REPAIR GUY IN LONGWOOD FL 32750I HAVE SOME PARTS FOR THESE PUMPS LISTED ON EBAY. PLESE VOTE YES OR NO IF I WAS OF HELP
5/19/2012 10:51:11 PM • Jacuzzi Pool &... • Answered on May 19, 2012
0helpful
1answer

Spa kicks off in a cycle. needs to be reset

Dean,Thank you for asking me to help you with your problem. However, this is either not within my level of expertise or the question is unclear or there is not enough information and I cannot help you at ths time.
12/17/2011 6:26:56 PM • Jacuzzi Pool &... • Answered on Dec 17, 2011
Not finding what you are looking for?
Jacuzzi MAGNUM FORCE POOL PUMP  2 HP 115230V  94027120 Logo

24 questions posted

Ask a Question

Usually answered in minutes!

Top Jacuzzi Pool & Spa Experts

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

john h

Level 3 Expert

29494 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Jacuzzi Pool and Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Jacuzzi Pool & Spa

  • Jacuzzi Pool & Spa

Most Popular Question

1 1 2 hp magnum force pump jacuzzi

  • Pool & Spa
Loading...