Tigra Electric Roof & Boot Problems
You need to pump the hydraulics manually, to do this first sit on boot and press boot button for a few seconds without allowing the boot to open. Partially allow boot to open, manually push boot all the way open and closed a dozen or so times to manually pump hydraulics. I had same prob, this sounds extreme but does work and wont cost you a penny.
SOURCE: SAAB convertible roof wont open
I managed to sort the problem, turns out there's a shear pin. I found this pin sitting in the bag in the back (the one the roof folds into) Now i just have to replace that and hopefully it should work
SOURCE: 2005 mini convertible roof wont open motors work but nothing open
check the parcel shelf has been refitted correctly as there is a micro switch on the left hand side that stops the second stage of the roof from opening
SOURCE: 2000 MERCEDES SLK ELECTRIC ROOF PROBLEM
hi,seem only adjustment of micro switch,to detect which switch are need to adj.you need to send to dealer.
SOURCE: Mercedes slk roof problem
hi,seem only adjustment of micro switch,but you need a tester(handheld tster) only a dealer have,
SOURCE: my 1999 slk's roof wont go down it gets as far as
This symptom almost always points to a mechanical issue, not an
electrical one. The SLK hardtop is notorious for needing to be
lubricated every couple of years. Here is a link with directions and
photos:
http://www.benzworld.org/forums/r170-slk-class/1426014-lubing-vario-roof-pics-1-krytox.html
Sticking
joints are the most common culprit to intermittent raising and lowering
problems. Once those have been lubricated and that has been checked off
the list, then consider looking into electrical issues.
The moisture from the rain may be helping to lubricate these joints and that might be why it works fine in the rain...