Questions & Answers for: water coming split ac

...water coming out from the outlet tube, which was not seen earlier. For your information, my split AC is 2 years old (approx.) Draim pans do get dirty and partialy block drain pan. If possible take a ...

Ad

Question about Heating & Cooling

1 Answer

...Split Ac, my technecians recharge the gas and solves the problem , but this is carried out at every 3-4 months, even they have checked all the connections for any leakage, but every connections are ...

Ad

...the water leakage in the indoor unit. Kindly advise the water comes from the coil, start there make sure there is no obstruction coming out to your condensate line and make sure its properly

Question about Mr. Slim MXZ30TN Air Conditioner

1 Answer

water coming out of my indoor unit. So much water that I had to shut off the ac unit. It is a Mitsubishi Mr Slim split type air conditioner/heating unit water coming out of an a/c is normal .its water

Question about 38CKC042 Air Conditioner

1 Answer

water coming from split ac Check the filter for your split ac and clean it if it has dust stuck in the panel.

Question about 38CKC042 Air Conditioner

1 Answer

...coming out at end of hose Most AC units has a slinger on the condenser fan blade that slings the water onto the cond. coil it makes the unit more efficient, if you are getting a 20 degree split ...

Question about LSC121PMA Split System Air Conditioner

1 Answer

water coming out of lg ac water starts coming out whenever humidity is high Your unit will have an external vented drain, check to make sure this is not blocked with fluff or dirt as this will cause ...

Question about LSC121PMA Split System Air Conditioner

2 Answers

...Split AC was not cooling yesterday night. On close watch I figured out that only internal unit was working but fan in outdoor unit was still together with compressor. Whenever compressor starts the ...

...engine is idling there is not enough vacuum to operate the valve that controls the water flow through your heater/ac. Pretty cheap fix unless the split is up under the dash Let me know how you get ...

Question about Asu9rlq 9000 Btu Indoor Mini-split Ac/hp Wall Fan Coil

1 Answer

Why is Water is coming out of my Fujitsu in the bottom right corner? Check the condensate drain tube for blockage.

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

Paul Carew

Level 3 Expert

3808 Answers

john h

Level 3 Expert

29494 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Heating & Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...