Frigidaire PLHS237ZD Stainless Steel Side by Side Refrigerator Logo
Posted on Jun 14, 2008
Answered by a Fixya Expert

Trustworthy Expert Solutions

At Fixya.com, our trusted experts are meticulously vetted and possess extensive experience in their respective fields. Backed by a community of knowledgeable professionals, our platform ensures that the solutions provided are thoroughly researched and validated.

View Our Top Experts

Warm frigerator FRIG WARM. FREEZER OK. BLOWER NOT WORKING ON TOP. CLEANED CENDENSOR COIL. DAMPER OK. FAN IS RUNNING. NO COLD AIR IN FRIG.

  • 1 more comment 
  • jrwikey Jul 30, 2008

    I have cleaned the condenser, i hear the freezer runing and it works fine, there is no air movement in the top of the frigerator,,,do not know how to check the damper.

  • Anonymous Mar 27, 2014

    WARM TOO NOT COLD IN FRIG

  • Anonymous Mar 27, 2014

    WARM TO NOT SO COLD IN FRIG

×

2 Answers

Anonymous

Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Vice President:

An expert whose answer got voted for 100 times.

  • Master 481 Answers
  • Posted on Jul 10, 2008
Anonymous
Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Vice President:

An expert whose answer got voted for 100 times.

Joined: Jun 27, 2008
Answers
481
Questions
4
Helped
196301
Points
1375

Sounds like a defrost problem. Check to see if there is any frost buildup in the back wall of the freezer. If so, it is not defrosting as it should.

  • possible causes:
  1. bad defrost timer
  2. bad defrost heater (in freezer)
  3. bad thermo switch in freezer
If you don’t know what these are then unplug the machine and let the ice melt in the freezer overnight with the door open. Then try it the next day, if is cooling fine then you need to have a service person replace one of the above items.
if you already checked this and think it is a different problem then let me know, i will help you figure it out. 
Mike  

Anonymous

Level 1:

An expert who has achieved level 1.

  • Contributor 1 Answer
  • Posted on Jul 14, 2008
Anonymous
Contributor
Level 1:

An expert who has achieved level 1.

Joined: Jul 14, 2008
Answers
1
Questions
0
Helped
367
Points
2

The frige is not that cold some stuff would be cold but the top would not be as cold as other stuff help [email protected]

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Frig too warm on top, too cold on bottom

inside the fridge section you have a fan damper assy.if you go here you can see it
http://www.repairclinic.com/PartDetail/Damper/WR49X10091/1055112
part number WR49X10091,the cold air comes through the damper and the fan in it blows the cold around into the fridge section,warm air rises so this is why it's warm on top and colder on the bottom.i just installed this part for a customer,unplug the machine or shut it down,remove the 4 screws that hold the top light assy. on drop it down,unplug the wire harness,pop off the cover to the water filter,remove the top two shelves then pop off the middle cover on the back wall,this allows you to remove the two screws that are behind it,remove all screws and remove the damper fan assy.look at the instructions,the one i worked on i had to remove the gasket that's on the freezer wall side and replace it with the fat gasket in the box and then put it back together again,it took me around 35 minutes to do the job.hope this helps you out
0helpful
1answer

The blower in frig is not working, frig is warm freezer is working fine, we have vacuumed all area & unplugged for serveral hours. please tell us what else we can try.

all it does is blow cold air from the freezer into the fridge section,open the freezer door,you should hear the fan blowing,no fan fridge will be warm bad evap fan motor,also send the brand name and model number,some machines have dampers in them if the damper is bad it blocks the cold air from entering the fridge section,send model number and brand name,
1helpful
1answer

Frig won't cool RM2652

You'll need to get in touch with the store you bought it from but Cut everything off for a few minutes then turn it back on and listen for a click from the compressor relay as the compressor tries to start.
Is the compressor motor running.If no check starter/overload relay. Check to see if the condenser fan at the back underneath near the compressor is running. If no check fan.

Are the condenser coils near there warm or room temp. should be warm




Is the evaporator fan in the freezer running. It blows cold air into the fridge side through a damper in the wall between the freezer and fridge. Make sure the damper is open.

Below the evaporator fan is the evaporator coils. Remove the back cover in the freezer to observe the frost pattern. Light frost everywhere(NORMAL) or a partial pattern of ice(LOW ON FREON) or nothing(LOW FREON OR COMPRESSOR PROBLEM).

0helpful
1answer

Jcd 2389GT frig side by side does NOT appear to be getting cold. What could be wrong? Thermostat? Compressor? How can I test it? Fan for freezer is running but also appears to be generating cold air. Can...

Normal 0 MicrosoftInternetExplorer4 st1\:*{behavior:url(#ieooui) } /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman"; mso-fareast-font-family:"Times New Roman";} . Cut everything off for a few minutes then turn it back on and listen for a click from the compressor relay as the compressor tries to start.
Is the compressor motor running.If no check starter/overload relay.
Check to see if the condenser fan at the back underneath near the compressor is running. If no check fan.

Are the condenser coils near there warm or room temp. should be warm


How to check stuff>
http://www.acmehowto.com/howto/appliance/refrigerator/refrigerator.php


Is the evaporator fan in the freezer running. It blows cold air into the fridge side through a damper in the wall between the freezer and fridge. Make sure the damper is open.

Below the evaporator fan is the evaporator coils. Remove the back cover in the freezer to observe the frost pattern. Light frost everywhere(NORMAL) or a partial pattern of ice(LOW ON FREON) or nothing(LOW FREON OR COMPRESSOR PROBLEM). Heavy frost indicates defrost problem.

0helpful
1answer

Freezer works but frigerator does not

The fridge gets its cold air from the freezer through a vent(damper) between the freezer and fridge.The fan in the freezer blows air through it. There is a flap you adjust with the fridge temp. control. Make sure it's opening and closing when you adjust the fridge temp

OR..
If the evaporator coils behind the back panel of the freezer are icing up because of auto defrost failure that will stop the circulation of cold air and eventually affect the freezer too.

check defrost timer, defrost heater, defrost thermostat. In most newer models the timer has been replaced by an electronic control board. If the heater and thermostat are ok it’ll be the control.

You can turn the defrost timer till it clicks and everything shuts down. The heater should now come on. If it does, replace the timer. If it doesn't, check the heater and defrost thermostat. Turn the timer again till everything starts back up to end the defrost cycle.

1helpful
1answer

My fridge freezer comprises of the top one being the fridge and bottom is the freezer. its Zanussi by Electrolux . problem is the fridge is not functioning and its warm (its not cold at all) but freezer is...

It sounds like the fan in your freezer is not working so it can't get the cold air to the frig or your coils are not defrosting and it is stopped u and cant blow air into te frig, One way to check if you hear the fan and know that it is working open the frig and put your hand up near the vent to see if you can fill cold air if you can't now open the freezer door if you can feel the cold air or more air r coils then you could before then your coils are stoped up the unit is not defrosting.
1helpful
1answer

Cold freezer/warm refrigerator

Same problem with Frigidaire Gallery model#GLRT182SAW5 (dated 2002 on back of case)

Vents were blocked with ice. Vents (from top compartment to lower) located behind light. You can check by poking a chopstick up the (2) holes; be careful not to hit fan blades.

Solution:

- took freezer coil cover off in back; checked that defrost heater element was working (marked and rotated the timer in the hole next to light); checked that fan working. Found ice in the vents and defrost drip area. Got it out with hair dryer.

- cleaned compressor coils in back (check fan is rotating; also tweaked some of the compressor tubing bends to make them more smooth - read somewhere about a manufacturing defect ...); blew out drip tube from defroster while down there.

- Set the freezer control to WARM and the refrig control to COLD (THIS SHOULD IMPROVE AIR FLOW FROM TOP TO BOTTOM).

- Put thermometers in top and bottom. Checked that refrigerator cycles (not running continuously). Checked that cold air is coming down from (2) vents behind light.

OK: so far, so good. Lower compartment is 40 or under. Top is under 18.

CONCLUSION: Suspect marginal design. Had problems with another similar model where defroster ice doesn't drain correctly, pools and refreezes. Leading to blocked vents as well as blocked defroster drain and similar problem including dripping water from top to bottom and warm bottom.

MAYBE KEEPING THE FREEZER CONTROL AT WARM GETS AROUND THE PROBLEM?? ANYWAY, ITS WORKING FOR ME FOR NOW !!
0helpful
1answer

My frigerator

This will get warm. If very hot check and clean coils in front, underneath. Also check fan behind rear panel. It should be turning when the unit is running. Also check for door not closing properly.
0helpful
1answer

Frig not cold but freezer is ice maker not making much ice either

Is your fan blowing in the freezer? Frost on the back wall of the freezer usually indicates a defrost problem... defrost themostate, heaters, take back panel off and check evap for frost build up and if your fan in working.
0helpful
1answer

FRIG AFD2535DES FRENCH DOOR BOTTOM FREEZER

Is your freezer fan blowing when the ref. is running, should feel air coming out the vent then,,,when running.
Not finding what you are looking for?

377 views

Ask a Question

Usually answered in minutes!

Top Frigidaire Refrigerators Experts

Mike Cairns
Mike Cairns

Level 3 Expert

3054 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

john h

Level 3 Expert

29494 Answers

Are you a Frigidaire Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides