The motor controller weakens over time because of the excessive amperage draw of the motor do to lack of lubrication (which wears the walk belt and walking deck).
Take an amperage reading of the motor it should be 2-3 amps with no one on it, with someone walking on it it should be around 6-12 amps. I would bet yours is elevated above 6-12 amps.The controller is dropping output because of the friction problem.
The first thing to try after testing the amperage is to lubricate the walking platform. Then retest and see if the amperage comes down and it doesn't shut off.
If it does then the next step would be to replace the walking deck. If the amperage still is up you may need to replace the walk belt second and finally if after replacing the deck and belt, if the unit is still shutting down replace the motor controller.