SOURCE: ZANUSSI ZJD12191 WASHER/DRYER
Washer dryers often have cold water valves with 3 separate solenoids.
One for the main wash and rinses (which is clearly ok) and one for the
condition rinse (to take the fabric conditioner down) which is probably
ok too, and the 3rd one is for the dryer. It's possible this 3rd
solenoid has failed.
Washer
dryers need on a steady trickle of cold water running into the
condenser chamber to convert the steam into water, which then gets
pumped down the drain.
SOURCE: I have a zanussi washer dryer zwd1471s, I have
Has a fan inside that blows air over clothing. Could be fan not operating....Thus overload stat swithing off heaters....
130 views