Bosch AquaStar 2400ES-NG  "error code ea" Questions

Ad

Question about Bosch Water Heaters

1 Answer

...error code ea Water heater had error code ea. Replaced ignitition module and that worked for about 1 week. Now every time you turn on the hot water you get the error code ea. Copy following links to ...

Ad

Question about Bosch Water Heaters

2 Answers

error code ea Bosch 1-866-642-3198; 800-642-3111Copy following links to narrow down cause for EA error ...

Ad

Question about Bosch Water Heaters

1 Answer

Error Code EA - not in owner's manual Bosch 2400ES NG - error code EA comes up when the burner turns on. I contacted Bosch and they indicated that it was a sensor problem. I tried to measure the ...

Question about Bosch Water Heaters

1 Answer

...error code. EA: No flame ionization detected with water flow. Verify that all manual gas shut off valves are open. Check gas type. Reset error code and open a water tap to cycle the heater in an ...

Question about Bosch Water Heaters

1 Answer

...error code and open a water tap to cycle the heater in an effort to purge air on new installations. Cycling hot water tap on and off multiple times may be necessary. If heater still faults with EA ...

...Error code EA - No sparks for the electrodes The ionization electrodes are not making sparks when water is flowing. There are many reasons for this problem and here are some; low gas pressure, fan ...

Question about Bosch Water Heaters

1 Answer

...error_code_troubleshooting.pdf http://waterheatertimer.org/pdf/Bosch-GWH2400ES-error-codes.pdf http://waterheatertimer.org/pdf/Bosch_A4-E4_error_code_troubleshooting.pdf Error code AE is not shown, ...

Question about Bosch Water Heaters

1 Answer

...error_code_troubleshooting.pdf http://waterheatertimer.org/pdf/Bosch-GWH2400ES-error-codes.pdf http://waterheatertimer.org/pdf/Bosch_A4-E4_error_code_troubleshooting.pdf Error code AE is not shown, ...

Question about Bosch Water Heaters

1 Answer

...error code of EA. What can be the problem? Verify that all manual gas shut off valves are open. Verify gas type (See Fig. 2 in installation manual) corresponds with the type of gas supplied to the ...

...Error Code EA appears, I hear ignitor clicking, heater tries to activate 3 times then EA code reappears. There are three electrodes (connected next to each other by a single piece of metal) that run ...

Not finding what you are looking for?
Bosch AquaStar 2400ES-NG  Logo

100 questions posted

Ask a Question

Usually answered in minutes!

Top Bosch Water Heaters Experts

john h

Level 3 Expert

29494 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Bosch Water Heater Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...