3000 VA UPS Service Manaul of Fiskars Power Systems Make

I own a 3000 VA UPS, which is dead and I want to repair it for which need its circuit diagram and service manual. The detail are as under.

UPS : 3000 VA (2100 Watts)
Make : M/s. Fiskars Power Systems, Maxico
Battery : 48 V DC (External)
Input : 220/230 V AC 50 Hz
Output : 220/230 V DC 50 Hz

Make : M/s. Fiskars Power Systems, Maxico
Part No. 05103604-0401
Serial No. A00239421
PCB No. 05141084

If any knows from where to get the circuit diagram and service manual, please be generous to help me out.

Sanjay Sahu
Jamshedpur India
E-mail : [email protected] or [email protected]

  • Anonymous Sep 04, 2008

    i have same problem please suggest

×

1 Answer

all-is-info

Level 1:

An expert who has achieved level 1.

Corporal:

An expert that has over 10 points.

Mayor:

An expert whose answer got voted for 2 times.

Problem Solver:

An expert who has answered 5 questions.

  • Contributor 7 Answers
  • Posted on Mar 30, 2010
all-is-info
Contributor
Level 1:

An expert who has achieved level 1.

Corporal:

An expert that has over 10 points.

Mayor:

An expert whose answer got voted for 2 times.

Problem Solver:

An expert who has answered 5 questions.

Joined: Jun 30, 2009
Answers
7
Questions
2
Helped
5100
Points
10

I have the same PCB on my Deltec PRR2200i. I at least know a few things about the circuit now. I had 11 transistors explode on mine and am replacing them now. Sadly I have not managed to track down a circuit diagram.

  • all-is-info Mar 30, 2010

    Oh, I used 2N2907A to replace the drivers Q29-Q32 and STP40NF10L to
    replace the ouput transistors.

    If you look at the 20 output transistors, they're all the same. Mapping
    it out a little shows its a full bridge driver with two totem-pole type
    ouput columns, the primary of the transformer is strung between their
    middles. Further back in the circuit there are two PWM controller chips,
    so I guessed they would be used to switch the stages on and off to
    shape a sine wave - perhaps also using that magnetic sensor thing to
    help, but not sure how.

    In my case, output rows 1 and 2 had blown, indicating they were both
    being driven ON, which should never happen. Over 200 amps straight from
    the battery would fry them in short order. The driver for row 2 (Q29)
    was also fried, and if that leaves row 2 ON, it will short out 50 times a
    second. This is what I think happened, but there are alternative
    scenarious.

×

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1helpful
1answer

AC N fuse blown

The AC rectifier section circuit inside it has short circuited component/s. Contact any service technician. This is not a user repairable work. http://electronicshelponline.blogspot.com/
0helpful
1answer

Internal fault 02

inverter fault power board must be replaced
0helpful
1answer
0helpful
2answers
3helpful
3answers

Does not power on

Please check whether you are getting any power on the UPS or not. In case it is not working even on the AC power, then it might be the transformer inside the UPS which has burned. It can be easily repaired by taking it to any APC service center. This does not seem to be an issue with the battery since the UPS is not even turning on
3helpful
2answers

Overload LED lit, constant warning tone, no load

you may have to many things plugged into the ups, it is not good to plug a power bar into one of the outlets of one of these as you are OVERLOADING the device with more power than it can produce
6helpful
2answers

Apc smart ups su1000, su750i and sua700inet circuit diagram

you mean you need a circuit diagram for the following APC unit? i dont think so if you can get unless theres one MF from APC manufacturing or service center that can give it or sell it to you. beacuse as far as i am concerned it is punishable by law to sell or to give copy of all circuit diagram of APC products. Good luck
0helpful
1answer

Ups power and charging problem

how old is your UPS? It seems that you need to replace the battery.
0helpful
1answer
0helpful
1answer

Ups taking no load and gets of within 30 seconds

I thought Fiskars quit making UPS, after powerware bought them out ages ago.

Two hours...you need a much bigger UPS to get two hours of run time. A 2200VA depending on t he load is a challenge to run two hours. Something like that would cost $400.00

30 seconds sounds like an over load issue.
Not finding what you are looking for?

2,825 views

Ask a Question

Usually answered in minutes!

Top Fiskars Brands Computers & Internet Experts

Grand Canyon Tech
Grand Canyon Tech

Level 3 Expert

3867 Answers

Brad Brown

Level 3 Expert

19187 Answers

Cindy Wells

Level 3 Expert

6688 Answers

Are you a Fiskars Brands Computer and Internet Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...