You have ST01C timer.
If I understand correctly, timer is wired for 3-way and was working fine before.
Now, the timer is no longer letting the 2nd 3-way switch operate.
I tested this timer.
When the red and blue wires on timer are connected, the timer reverses.
When the red and blue wires are disconnected, the timer reverses back.
So the 2nd 3-way switch merely connects and disconnects the red and blue wire on timer.
This is why wiring is different on 2nd 3-way switch, and not like ordinary 3-way wiring.
http://waterheatertimer.org/images/ST01C-EJ500-w-3-way-450.jpgThis means that a) Timer has gone bad or b) 2nd 3-way switch has gone bad.
1) Replace 2nd 3-way switch
2) ST01C instructions say as last resort, reset timer.
However all timer programs will be lost.
Open following link to read steps for resetting and reprogramming timer, plus wiring diagrams.
http://waterheatertimer.org/ST01C-program.html3) Replace timer
Amazon:
http://www.amazon.com/Intermatic-ST01C-Digital-wall-Timer/dp/B0045D3D16Aplussupply
http://www.aplussupply.com/intermatic/timer.htmAdd a comment for more free help.