david gaume Posted on Jan 12, 2013
Answered by a Fixya Expert

Trustworthy Expert Solutions

At Fixya.com, our trusted experts are meticulously vetted and possess extensive experience in their respective fields. Backed by a community of knowledgeable professionals, our platform ensures that the solutions provided are thoroughly researched and validated.

View Our Top Experts

Replace battery on precor efx 546 - Precor Efx 546 Version 1 Lower Body Elliptical Crosstrainer, 110v

1 Answer

Sportsmith LLC

Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

  • Precor Master 920 Answers
  • Posted on Jun 30, 2014
Sportsmith LLC
Precor Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Joined: Apr 23, 2014
Answers
920
Questions
0
Helped
514919
Points
111994

1 Related Answer

ercupa190

ernesto cuadra

  • 12223 Answers
  • Posted on Mar 15, 2013

SOURCE: precor efx 546 error.

please follow this steps and fix it. God bless youError 43 - Zero Switch not FoundDescriptionThe C944 and several versions of C96X used a lift position identification system that did notutilize a potentiometer.Instead, it utilized a switch that would be physically actuated by the lift when the lift was in thezero incline position. A revolution sensor counted lifted motor revolutions to determinesubsequent lift positions. In addition two limit switches where used to remove power from the liftmotor if the lift moved outside of it's normal range.When the unit was powered up the lift would start to hunt for the zero switch. It would first go up4% (maximum lowest physical position was -3%) if it did not find the zero switch or it hit the upperlimit switch, it would then go down until did find the zero switch. When the zero switch waslocated it would stop, the system would then know its physical position and be prepared tomonitor the revolution sensor. If during this power up procedure the zero switch was not found anerror 43 would be displayed.Possible Causes1. The lift position actuator does not physically operate the zero switch.2. The lower PCA is bad.3. The zero switch is bad.Possible Remedies1. There are several physical problems related to the lift platform mounting or the plate the zeroswitch is mounted on that can cause the actuator knob to miss the zero switch as it movespast. Repair the lift platform mounting, repair or replace the lift switch mounting plate asrequired.2. The lower PCA provides a 5 VDC power source for the zero switch. You should measure 5VDC across the zero switch when the zero switch is activated. If the reading is significantlylow, remove both wires from the zero switch and repeat the measurement across the wiresremoved from the zero switch. If the reading is still significantly low, verify the zero switchwiring. If the wiring is intact and correctly connected, replace the lower PCA.3. Move the lift to position where the zero is switch is not activated and remove power from thetreadmill. Remove both leads from the zero switch and measure the zero switch with anohmmeter. The zero switch should read very near 0 ohms. While measuring the zero switchwith the ohmmeter, activate the switch by hand, the reading should change to infinite (open).If either of the above readings are significantly incorrect, replace the zero switch.

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

What causes a slow boot up on a Precor EFX 546?

A slow boot up on a Precor EFX 546 elliptical machine can be caused by several factors, including:
  1. Low battery voltage: If the battery voltage is low, the machine may take longer to boot up. This can be due to a weak or old battery, or a problem with the battery charger.
  2. Dirty or corroded contacts: Dirt, dust, or corrosion on the battery contacts or other electrical contacts can interfere with the machine's ability to start up quickly.
  3. Faulty console or display board: If the console or display board is malfunctioning, it may take longer for the machine to boot up or may not boot up at all.
  4. Loose or damaged cables or connections: Loose or damaged cables or connections can prevent the machine from starting up properly and may cause a slow boot up.
  5. Outdated software: If the software on the machine is outdated, it may take longer for the machine to boot up or it may not start up at all.
To troubleshoot a slow boot up on a Precor EFX 546, you can try the following steps:
  1. Check the battery voltage and replace the battery if necessary.
  2. Clean the contacts on the battery and other electrical components.
  3. Inspect the cables and connections for damage or looseness.
  4. Check for any error codes or messages on the console or display board and consult the user manual for troubleshooting steps.
  5. Check for any available software updates and install them if necessary.
If none of these steps resolve the issue, you may need to contact a professional technician for further assistance.
0helpful
1answer

Can I adjust the stride length?

Precor EFX 546 Version 1 Elliptical Trainer (Refurbished)

www.amazon.com > ... > Elliptical Trainers

Amazon.com, Inc.
Rating: 4.3 - ‎9 reviews
Working out on an elliptical can burn as many calories as working out on a treadmill. ...allowing you to go forward and backward, as well as adjust stride length to target ...The Precor EFX 546 allows you to stride smoothly while holding the ...

EFX® 546i Elliptical Fitness Crosstrainer™ ' Precor

www.precor.com/en-us/.../efx-546i-elliptical-fitness-crosstrainer-33
With the unique Precor CrossRamp® technology, users can alter the path of the EFX®546i between 13 and 40 degrees in both forward and reverse stride motions, cross ...Excellent stability and freedom of movement for users of all sizes.

FAQ - Precor


0helpful
2answers

What kind of battery do i need for efx 546?

There a few possible options for the battery. This link will take you to all of them. Please have your serial number ready to help narrow your choices.

Repair Parts for Precor EFX 546i Ellipticals SPORTSMITH net
0helpful
1answer

My precor efx 546 makes noise like a squeaking in left pedal it seems I tried to tighten pedal but I the whole bolt and screw turn together and the other pedal makes no noise

This squeak is normally caused by a bad bearing in the wheel. In order to provide you with the correct wheel, I will need your serial number. The following link will take you to our Precor EFX 546 page.

Repair Parts for Precor EFX 546 Ellipticals SPORTSMITH net
0helpful
1answer

Precor efx 546 wobbles when raising incline

It may be either the front shroud is installed incorrectly or broken, or the corkscrew for the incline motor is bent. If it is bent, it would need to be replaced.

Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/russell_1d1c35fa8a5a0be4

0helpful
1answer

How to repair a 546 efx precor

Assuming the buttons are working, the numbers change on the display, and the incline works, it may be the lower circuit board or the generator. If it is a very old unit, it may be the electromagnet or the data cable that connects the two circuit boards.

Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/russell_1d1c35fa8a5a0be4

0helpful
1answer

I have a Precor EFX 546. How do I replace the drive belt?

Using your model and serial number, use this link to view a service manual with procedure instructions. http://www.sportsmith.net/
1helpful
1answer

Error 45 on Precor EFX 546 Elliptical

Precor Error 45, Lift Moving in Wrong Direction Probable Cause 1. Lift motor hysteresis.
2. Lower PCA is bad.
Corrective Action 1. The error would usually occur when the lift was already in motion (usually downward) when a lift command in the opposite direction (upward) was made. Some lift motors used in production exhibited a very long turnaround time and the lift motor would still be moving in the original commanded direction while the control system was trying to move the lift in the opposite commanded direction. If the error continues to re-occur, replace the lift motor.
2. It is a rare condition, however if the lift moves in the opposite direction commanded, replace the lower PCA.

Precor Error Code 45
Not finding what you are looking for?

973 views

Ask a Question

Usually answered in minutes!

Top Precor Exercise & Fitness Experts

Sportsmith LLC
Sportsmith LLC

Level 3 Expert

920 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Grand Canyon Tech
Grand Canyon Tech

Level 3 Expert

3867 Answers

Are you a Precor Exercise and Fitnes Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...