Posted on Mar 29, 2017

I HAVE HAD A HOTPOINT FRIDGE FREEZER FOR SOME YEARS.

LAST WEEKEND IT STOPPED WORKING AND GAS FUMES EMITTED FROM THE FREEZER. FOOD WAS THAWED AND CONTAMINATED. I MADE AN APPLICATION TO CLAIM THROUGH MY INSURANCE BUT AS OF TODAY, THEY STILL HAVE NOT EVALUATED MY CLAIM AS THEY CANNOT FIND THE SPECIFICATIONS OF MY FRIDGE FREEZER. I HAVE NOT KEPT THE LITERATURE THAT CAME WITH THIS MACHINE BUT THE WRITING ON THE FRONT OF MY FRIDGE SAYS 8332. ON CHECKING THE WEB, I STILL CANNOT FIND THIS TYPE OF MACHINE. WOULD YOU KNOW IF THIS MACHINE IS SIMILAR TO ANY OTHER TYPE OF FRIDGE FREEZER YOU HAVE ON SALE AT THE MOMENT AS MY INSURANCE COMPANY WILL NOT PAY UP UNTIL I PROVIDE THEM WITH SOME TYPE OF SPECIFICATIONS AT 2.30 TODAY. I AM NEARLY DEMENTED. PLEASE HELP.

5 Related Answers

Anonymous

  • 149 Answers
  • Posted on Apr 23, 2008

SOURCE: LEC Fridge Freezer

clean up your condenser it's gotta be dirty and check your thermostat put it on the coldest setting and check your freezer fan.

if t ain't running check to see if wired with defrost thermostat if it is suspect it defective.

Ad

Anonymous

  • 93 Answers
  • Posted on Jul 18, 2008

SOURCE: Upright freezer keeps thawing & re-freezing??

check your defrost timer

Anonymous

  • 97 Answers
  • Posted on Apr 05, 2010

SOURCE: FREEZER MAKING ICE, BUT FOOD IS THAWING

If you have a Freezer on the top model Kenmore, with warm temps in the fridge, AND water dripping onto the top shelf of the lower fresh food compartment (FFC), this is usually caused by a clogged defrost drain. Since Kenmore is not an actual manufacturer of anything, they take other brands, i.e. Kitchenaid, GE, Frigidaire, etc., take their names off and put on a shiny Kenmore nametag. This is a common problem with Kitchenaid refrigerators. You can determine if your Kenmore is made by kitchenaid by looking at the model # tag. the first three digits will indicate the manufacturer, Kitchenaids begin with the sequence, 106.*.If this is indeed how your model # begins, keep reading. Since the water cant go down the drain tubing to the pan at the bottom of the unit, it builds up on the freezer floor, eventually blocking the air return vents from the fridge to the freezer, and the vent from the freezer to the fridge. YOu can check this very easily. Look at the ceiling of your FFC, near the back. toward the sides you will see two square holes, about 2" square, stick your finger and feel around the inside of those holes, do you feel any ice/frost, or do you just feel styrofoam, you might even see frost/ice below the level of your ceiling? This drain usually gets clogged with defrost water that does not completely drain, then of course it freezes, eventually plugging up the drian hole located at the level of your freezer floor, behind the back wall. The water keeps accumulating, and freezing, on the freezer floor, eventually filling in and clogging the air vents..no air flow , the fridge wont cool. The easiest way to resolve this, empty out all contents and store someplace cold for 24 hours...a 2nd fridge, outside in a cooler if its cold like here in chicago. After its empty, unplug, open both doors and blow a fan for 24 hours. Prepare for an abundance of water due to melting ice.
After you defrost, you can plug it back in and it will be fine, HOWEVER, I suggest you take the back freezer wall off, you might have to take a floor cover off first, likely 2-4 screws in both the floor and the back wall. When you have the evaporator exposed, you will see a black cal rod defrost heater underneath the evaporator, as well as your drain hole just to the right of center underneath both heater and evaporator. Take a piece of 12-14 gauge solid, not stranded wire, removing the insulation and exposing the entire 6-8" piece of copper wire. wrap the wire around the diameter of the cal rod heater, 3-4 turns should be sufficient, and stick the other end of the wire down that drain hole. This will melt any ice that will build up in the future, everytime your unit goes into defrost cycle, so this wont happen again.

If air vents are clear of frost/ice, next thing to check is the back wall of your freezer, does there appear to be frost/ice/snow on the back wall? If so, your unit is not defrosting. On most Kenmores, this is usually caused by your defrost timer, located in the canopy mounted at the top of the FFC on Top freezer models, or your defrost thermostat, which is clipped onto the evaporator coil inside your freezer. Again, if its a 106 model Kenmore, this thermostat will have a pink and a brown wire coming into/out of it. My suggestion, if it isnt defrosting, change both. tjhe defrost control will connect with a plug, but you will have to hard wire the thermostat, ( cut wires from old, strip wire, and connect using wire nuts and electrical tape.)

Since y ou mentioned the water accumulation, more water recently, my diagnosis would be the former versus the latter, as the lack of actual defrosting coincides with lack of defrost water, however I'll never say never.

If your unit is a side by side model, check for ice on freezer floor...clogged drain. Check again for frost/ice on back wall, not defrosting, check same two parts, (the heaters rarely go bad on Kitchenaids, but never say never) You should also check for air flow into fridge, even if no frost / ice visible on back wall. Open the FFC door, and locate the air vent near the top, back of the fridge, on the left wall. While depressing the door switch, AND WITH THE FREEZER door closed, put your finger/hand near that vent. Do you feel any cold air? If you dont, you could have a bad door damper, not uncommon, or a bad damper control--> the temperature control WITHOUT the off or "0" position.

If any of this seems a bit overwhelming, I suggest you have a reputable repair technician check your fridge.

Oh, and lastly, you WILL NOT have two compressors, one for each compartment, nor will you have two sets of defrost heating elements, one for each half.
ALL cooling for 99% of refrigerators made in last 25 years takes place in the freezer, with the fridge being an empty box, except for an air intake vent, and an air exhaust vent which leads directly back into the freezer. When a refrigerator unit seems to still be cold in the freezer, but not cold enough or not cold at all in the FFC, its ALWAYS going to be caused by lack of air flow. But as you can see, there are a few things that can cause that lack of air flow.

Anonymous

  • 43501 Answers
  • Posted on Apr 17, 2010

SOURCE: freezer not working

Hi,
As the weather is getting warmer for many people their freezer and/or refrigerator do not work right because of a dirty condenser coil...

Check out this tip that I wrote about that... it is a great place to start trouble shooting your unit...and something that you can do rather then calling a repair person to do a simple thing for you...

http://www.fixya.com/support/r4024657-refrigerator_condenser_coil_cleaning

heatman101

Anonymous

  • 389 Answers
  • Posted on Apr 21, 2010

SOURCE: brandt apollo fridge/freezer - food defrosts + salad freezes

Check the vents in the fridge side and close a little if you can. On the freezer side just for good measure>>>>
Is your circulating fan working?
Sometimes they stick and need a shot of WD 40 and then work
it back and forth a little until it wants to take off again. Keep me informed
and PLEASE give a Thumbs Up for the effort. The Raz Shack

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2helpful
1answer

Bosch FD8709 Fridge Freezer (American Style) Freezer section not cooling (Ice maker has stopped making cubes and food starting to thaw) Fridge section seems to be working OK..! In Manual says that the...

Hi,

Many times a freezer and/or refrigeratordo not work right because of a dirty condenser coil...there are also many otherthings that can go wrong. If you are hearing a clicking or buzzing thencheck out the last two tips.

If your refrigerator is running but warm, then...

Check out these tips that I wrote about that... it is a great place to starttrouble shooting your unit...and something that you can do rather then callinga repair person to do a simple thing for you...

Refrigerator Condenser Coil Cleaning Refrigerator Repair

Refrigerator Troubleshooting Refrigerator Compressor

Refrigerator Compressor Start Capacitor and Start Relay
Refrigerator or Freezer not Cooling or Getting Cold

heatman101
2helpful
1answer

Hi, i have a whirlpool american style fridge that beeps etc.

its the compresor packed up,,,if this compresor is not pumping freezer gas around the pipe work the freezer wont work sorry but a new compresor is not a cheep thing to have fitted as it will need a re-gas as well
Jun 29, 2010 • Freezers
3helpful
1answer

Hotpoint freezer, High temp light on & all food thawing

It's probably the defrost timer is getting stuck in the defrost mode. What it does it it periodically interrupts power to the compressor and sends power to the defrost coils to allow any frost on the cooling coils to melt to keep them clear of ice build up. This is typically a mechanical timer and sometimes the motor fails and it stop turning and if it fails in the defrost mode, the compressor never turns back on no matter how warm the freezer is.

You can confirm it is the timer, by tracing the wires from the compressor to a little 2 by 2 inch box which is the timer. On one side there should be a round hole with a plastic cam. You should be able to turn that cam with a flat screw driver or a coin. Just give it a slight turn until you hear a click. After you turned the cam, the compressor should start. If it does, then it is the timer.
Jun 29, 2010 • Freezers
0helpful
1answer

Freezer started emitting a chemical smell and food is thawing.

if its a sweet sickly smell then its possibly just a relay thats burnt out,should be cheap enough to replace,its the call out thats the killer.
1helpful
1answer

Maytag freezer keeps thawing food

I am no pro on these but it sounds like your defrost heating coils are coming on to often. You may want to check them. Aslo just for good measure>>>
Is your circulating fan working?
Sometimes they stick and need a shot of WD 40 and then work
it back and forth a little until it wants to take off again. Keep me informed
and PLEASE give a Thumbs Up for the effort. The Raz Shack
Feb 20, 2010 • Freezers
0helpful
1answer

Frosts up at front then food starts to defrost

It would appear to me the system has a leak. Allow me to explain. When a fridge/freezer is "lo" on gas it causes the compressor to run far longer than usual. As a consiquence the motor overload shuts it down, potentially for a very long time, hence the contents thaw. The major clue to this a frost pattern on just one wall. Have a tech visit to confirm, but I suspect you'll be out of luck as far as a repair goes. Chest freezers are not easy to repair "lo side" leaks, which is likely what you have, because the evap. coils are in the walls. sorry, but I hope that helps in some manner. good luck
1helpful
1answer
4helpful
4answers

GIBSON DEEP FREEZE IS RUNNING BUT EVERYTHING IS THAWING OUT

Might try unplugging for a few hours and then plug it back in. There is a possibility that it slugged the compressor and there is a restriction in the line. Sometimes when the compressor fails to stop running in cold air the liquid gets back to the compressor. It can cause a bit of gunk to be picked up out of the oil and carried to the expansion line and plug up the line. Maybe turning it off will let the plug fall free and not replug the line. Worth a try anyway.....
Feb 07, 2008 • Freezers
Not finding what you are looking for?

170 views

Ask a Question

Usually answered in minutes!

Top Hotpoint Freezers Experts

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66980 Answers

Thomas Perkins
Thomas Perkins

Level 3 Expert

15088 Answers

Stan Ford

Level 3 Expert

3131 Answers

Are you a Hotpoint Freezer Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...