Top 20 EnGenius EOC-3220 (EOC3220) Questions & Answers

1helpful
2answers

I have a Engenius 3220,

Try the program Belarc Advisor. It worked for me. I had the same problem when I updated the firmware of my EnGenius ERB9250 Extender. Once Belarc has displayed everything it has discovered about your computer, scroll down to the area labeled Network Map. There you will find your EnGenius 3220's IP.
8/22/2011 10:36:43 PM • EnGenius... • 585 views • 1 helpful votes
1helpful
2answers

I am trying to open

what about after you try and it displays a smiley face or other times none. what to do then?
4/5/2011 6:56:04 AM • EnGenius... • 390 views • 1 helpful votes
0helpful
1answer

MY INTERNET SPEED IS VERY

if the maximum speed capacity of your internet connection (provider)is low, all you have to do is find or change into a better or faster internet connection (provider). a DSL connection would be good.
4/10/2011 9:54:50 AM • EnGenius... • 170 views • 0 helpful votes
0helpful
1answer

HOW CAN I ACCELEARTE MY

if the maximum speed capacity of your internet connection (provider)is low, all you have to do is find or change into a better or faster internet connection (provider). a DSL connection would be good.

you can also try no to open various tabs or browsers at the same time. especially when downloading.
4/10/2011 9:51:12 AM • EnGenius... • 94 views • 0 helpful votes
0helpful
2answers

Took unit out of storage.

just try this. reset the hardware EOC-3220 then,
in your internet explorer browser type, 192.168.1.1 when you get in, it will ask username and password
put admin in username and leave the password blank. or put admin in username same in password.
hope it will help you.
2/4/2011 1:46:20 AM • EnGenius... • 364 views • 0 helpful votes
1helpful
1answer

My Seneo 3220 has changed its mac and gone to

I have no idea what it means for a Senao to "go to Realtek."
Here is the factory reset procedure for the Senao EOC-3220:

An RS-232 null modem serial cable is required for this procedure.


1. Connect the EOC-3220 to your computer with a null modem serial cable.


2. Start a HyperTerminal session: Click Start and then select Programs -> Accessories -> Communications -> HyperTerminal.


3. After the HyperTerminal window appears:


a. Give this new connection a name. Ex: EOC-3220.


b. Select correct COM port. Ex:COM1.


c. Set baud rate as "38400", data bits "8", parity "none", stop bits "1", and flow control as "None". Then press "OK" to bring up the HyperTerminal window.


4. Wait until the "#" is displayed in the HyperTerminal window.


5. Type "flash reset", then hit enter.


6. Type "reboot", then hit enter. After the device reboots, all settings will be at factory default.

10/25/2010 7:08:39 PM • EnGenius... • 530 views • 1 helpful votes
0helpful
1answer

Hi, I cannot setup my

You need to enable the DHCP server on the EOC-2611P. Then it will negotiate an IP address with your PC without you having to set one by hand.
8/12/2010 2:16:11 PM • EnGenius... • 1,005 views • 0 helpful votes
0helpful
1answer

How do I get into

There is no reset button on this model. To forcibly regain control of the configuration, you need a USB to serial cable, possibly a null modem adapter (depending on the serial cable), and a serial communication program like HyperTerminal or ZTerm for the Mac.
The manufacturer has incomprehensibly removed the detailed reset instructions from their website, but they can be found here:
http://www.keenansystems.com/engenius__senao_wifi_faq.htm
Look for the section titled "How do I reset the EOC-3220 / EOC-3220 EXT / EOC-3220+ back to factory default settings? "
8/30/2010 6:14:39 PM • EnGenius... • 528 views • 0 helpful votes
0helpful
1answer

Unable to connect to eoc3220 thru serial or

If you can connect to another, known-good EOC-3220 using the same serial cable and software setup, then your other EOC-3220 is probably just blown. It happens - I have several in a box in the workshop. :-(
10/11/2010 12:00:48 AM • EnGenius... • 146 views • 0 helpful votes
0helpful
1answer

I have EnGenius EOC-3220 (EOC3220)

Depending on the serial cable you have, you may need a modem (crossover) adapter between the cable and the EOC-3220. A good diagnostic is the following: with the EOC-3220 unplugged from power, connect your serial cable and make all the proper baud rate etc. settings in your serial communications program. When it is running, plug the EOC-3220 into power. If you don't see any garbage characters appear on your screen when you plug the power in, your comm program is probably not set up properly. If you see garbage characters but they are not immediately followed by good information from the EOC-3220, then you either need a null modem adapter inline, or you have a dead EOC-3220. If you've never communicated successfully with an EOC-3220 before over the serial channel, the only way to know if you have a dead one is to try again with a known-good one.
8/12/2010 10:38:36 AM • EnGenius... • 569 views • 0 helpful votes
0helpful
1answer

MY 2611 UNIT IS INSTALLED IN A REMOTE AREA THAT

go for the ruckus2942
9/14/2010 11:25:07 AM • EnGenius... • 204 views • 0 helpful votes
0helpful
1answer

We have a probleme whit

If you really wish to use WEP encryption, you should enter your WEP key in the key1 field. However, WEP is weak and breakable in under four seconds. I would recommend using the WPA encryption instead, with a passphrase. The AES mode is strongest, but the TKIP mode is compatible with more and older machines.
The reason you are getting "default encryption type mismatch" is because the encryption type has to be set exactly the same on the AP side and on the bridge side in order for you to communicate. When it is not the same type, you get this error. If it is the same type and you just have the wrong password, the error will be different.
9/11/2010 7:29:06 PM • EnGenius... • 195 views • 0 helpful votes
0helpful
1answer

I had a problem wen

hyperterminal not work. give me any other option.
9/2/2010 1:26:37 AM • EnGenius... • 204 views • 0 helpful votes
0helpful
1answer

Am using a engenius 3610 ext. but i forgot about

Check your hyperterminal settings and make sure the communications settings are correct: baud rate 57600, 8 bits, no parity, 1 stop bit, no flow control. telnet terminal ID ANSIW. The full directions are here:
http://www.engeniustech.com/datacom/support/general-details.aspx?id=109
If this doesn't work, and it doesn't work from a different computer either, then I would suspect your USB/Serial cable or your radio unit itself.
7/12/2010 10:32:40 AM • EnGenius... • 599 views • 0 helpful votes
0helpful
1answer

My Engenius access point is having problem wth the

Assuming you are using the proper serial channel reset procedure, this should not be occurring. If it is occurring, your unit is probably malfunctioning and cannot be corrected.
8/5/2010 9:28:02 AM • EnGenius... • 300 views • 0 helpful votes
0helpful
1answer

I was trying set up

192.168.0.3 is the default ip address...

click here for more details....

click here for wireless tips...
8/7/2010 2:55:48 AM • EnGenius... • 170 views • 0 helpful votes
0helpful
1answer

Ip problem eoc 3220 plus

Sorry, there is no problem statement here. Please describe your problem in more detail.
8/6/2010 1:48:43 AM • EnGenius... • 142 views • 0 helpful votes
0helpful
1answer

I have a EnGenius EOC-3220

I'm sorry, there is no problem statement here. If you have a specific problem, please provide it.
8/8/2010 2:26:28 AM • EnGenius... • 47 views • 0 helpful votes
0helpful
1answer

Trying to reset with serial cable and getting the

For that you need to RESET it.
1. Connect the EOC-3220 to your computer with a null modem serial cable.

2. Start a HyperTerminal session: Click Start and then select Programs -> Accessories -> Communications -> HyperTerminal.

3. After the HyperTerminal window appears:
a. Give this new connection a name. Ex: EOC-3220.
b. Select correct COM port. Ex:COM1.
c. Set baud rate as "38400", data bits "8", parity "none", stop bits "1", and flow control as "None". Then press “OK” to bring up the HyperTerminal window.
d. Unplug the power on the POE injector and wait 5 seconds then plug the power back in.

4. Wait until the "#" is displayed in the HyperTerminal window.

5. Type "flash reset", then hit enter.

6. Type "reboot", then hit enter. After the device reboots, all settings will be at factory default.
then configure it again.
Also uninstall wireless lan driver from computer then reinstall.
You can uninstall it from device manager and control panel->add remove programs.
Let me know if you need further assistance.
Thanks for using FixYa.
6/10/2010 5:00:14 PM • EnGenius... • 170 views • 0 helpful votes
1helpful
1answer

My friend has a router

unless its own IP was changed but it should really stay at 192.168.1.1 even if its DHCP is enabled or not. try to assign statically an IP, ofcourse different from the above to the PC you are using. if it picks, then ping the above IP, if ok, then try to login to the router. otherwise, for reset purposes, an RS-232 null modem serial cable is required. this would reset all settings to factory including the default IP. how to do this, please follow these steps.
1. Connect the EOC-3220 to your computer with a null modem serial cable.

2. Start a HyperTerminal session: Click Start and then select Programs -> Accessories -> Communications -> HyperTerminal.

3. After the HyperTerminal window appears:
a. Give this new connection a name. Ex: EOC-3220.
b. Select correct COM port. Ex:COM1.
c. Set baud rate as "38400", data bits "8", parity "none", stop bits "1", and flow control as "None". Then press “OK” to bring up the HyperTerminal window.
d. Unplug the power on the POE injector and wait 5 seconds then plug the power back in.

4. Wait until the "#" is displayed in the HyperTerminal window.

5. Type "flash reset", then hit enter.

6. Type "reboot", then hit enter. After the device reboots, all settings will be at factory default.
6/23/2010 10:29:52 AM • EnGenius... • 94 views • 1 helpful votes
Not finding what you are looking for?
EnGenius EOC-3220 (EOC3220) Logo

98 questions posted

Ask a Question

Usually answered in minutes!

Top EnGenius Computers & Internet Experts

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

Krzysztof Tomasz

Level 1 Expert

12 Answers

Are you an EnGenius Computer and Internet Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

EnGenius Computers & Internet

  • EnGenius Computers & Internet

Most Popular Question

am trying open

  • Computers & Internet
Loading...