Where can I buy a seal for my Woods upright freezer Model WV20-ZF1/E

Woods are no longer in business and all parts are obsolete. https://www.google.com/search?q=Woods+upright+freezer+WV20-ZF1%2FE+door+gasket So, you can either buy a door gasket by the size of the one you have, or you can make one by buying a length or door gasket material and cutting 90' notches in the 4 corners and filling / gluing the corners with white silicone. Or if the gasket is just split, you can clean thoroughly and repair with silicone. Fill the void, close the door, and clean up excess. https://www.searspartsdirect.com/model/3d1c1uazs3-003083/wc-wood-v20wb-upright-freezer-parts And then after typing all the above, I searched for the Part Number and there is one here! https://maxappliances.ca/product/woods-0-90000-046-wp4357142-gasket/ ..
10/31/2023 3:01:10 PM • Woods Freezers • Answered on Oct 31, 2023
0helpful
1answer

Woods Freezer. Where is the off position on it please?

Question edited for clarity. Question moved from Cars and Trucks category. Freezers don't have controls INSIDE the freezer, as it is too cold for efficient operation. Chest freezers have them on the outside behind the grille where the compressor is. Upright freezers usually has electronic controls on the door. You give o clue as to what type you have or what model you have. You can easily turn it off by removing the wall plug! Or you can find the manual. 'Off' on a thermostat is normally fully clockwise. https://www.google.com/search?q=woods+freezer+manual ..
3/18/2023 4:21:10 PM • Woods Freezers • Answered on Mar 18, 2023
0helpful
1answer

Woods C1017w3 chest freezer lid wont stay up??

Look at the back. There are counterbalance springs under the plastic hinge covers.
3/12/2022 7:28:54 PM • Woods Freezers • Answered on Mar 12, 2022
0helpful
1answer

What can I do? My Woods upright freezer model F17WCE has stopped freezing. It is still cold, but not cold enough freeze.

Hello; My name is Peter. I am a retired field service refrigeration technician. How do you know you fully defrosted the freezer? You have a defrost timer and heater to do that. Unplugging your unit for a few hours may not be enough. You need to remove the lower back wall cover. There are several screws holding it on and the rubber molding around it easily pulls out. Up plug your unit and remove the lower back cover. 1.) Frozen Drain - Your unit goes through a defrost cycle every 8-10 hours. During the time your freezer shuts down for 20-30 minutes except for your light. If you have a frozen drain, the condensate builds up behind the lower back wall until the cooling(evaporator) coils become plugged up and you do not get any air flow. You may even have a solid block of ice. Repair: Using a hair dryer (DO NOT Use Metal Objects. You may damage the coils.) slowly defrost the coils. This will take 2-3 hours. 2.) Cooling (Evaporator) Fan Failure - Assume the coils are not iced up. Is your evaporator fan running? 25386473-x2invnbvdad3ve0pcsobo2og-2-0.jpg Part #: 3-60336-001 Cost: $115.00 Check it out: With a multi-meter set to the lowest Ohms (Omega Symbol). Is the motor humming, Then it is bad and needs to get replaced. Unplug the unit. Disconnect the motor. Put one meter lead in one connector socket and the other lead in the other motor sock. You should get a reading of "0" Ohms if the motor is good. Anything else the motor is bad and need to be replaced. 3.) Defrost Timer - Pull your unit out to access the lower back. With your unit plugged in, take a small flat head screw driver, insert it into the slot on the time. Turning clockwise one turn at a time, until the freezer shuts off. If you have turned one full cycle, then you have a bad timer. Ok. The unit shut down except for the light. Observe the metal bar below your cooling coil. Is it hot? If not then you may have a bad defrost heater. Lets check it out - Unplug your unit. Once again with your multi-meter set on the lowest Ohms, disconnect each ends of the wire connectors. Be careful not to touch the fins on the cooling coil. They are razor sharp. The connector are hard to pull apart. Put one meter lead in one connector and the other meter lead into the other connector. If you do not get a Ohm reading between 50-250, then you have a bad defrost heater. 25386473-x2invnbvdad3ve0pcsobo2og-2-2.jpg Substitution: 3-80405-003 Cost: $56.00 This is a glass tube with a spring in it. If it is burner or the spring is broken then you have a bad defrost heater. 4.) Refrigerant Leak or Obstruction - With the unit plugged in. Lay the lover cover the cooling coils. Close the door and wait 30 minutes. Remove the cover. Do all of the coils have a nice frost pattern? Is there a block of ice in the upper right hand corner of the cooling coil. If so you either have a refrigerant leak or an obstruction. In this case the repair will cost you $450.00-$500.00. 5.) If all of the above is good, then you may have a Bi-mel problem. In the upper right hand corner of your cooling coil there is a thermostat. This controls the temperature and compressor start-up. This may explode in the back. Check to see if it is intacted. 5.) Bad thermostat - These can not be checked for failure. If you have check all of the above this may be your problem. 25386473-x2invnbvdad3ve0pcsobo2og-2-5.jpg Substitution: 4-83053-003 Cost: $68.00
3/2/2022 4:52:08 AM • Woods Freezers • Answered on Mar 02, 2022
0helpful
1answer

Bought this Chest Freezer from a Rummage Sale. Its

Try the gargler and google the maker and model.
2/9/2021 8:30:46 AM • Woods 4.3 cu.... • Answered on Feb 09, 2021
0helpful
1answer

Looking for a three wire connector for a woods chest freezer lid

post a picture of it
1/26/2021 7:45:11 PM • Woods Freezers • Answered on Jan 26, 2021
0helpful
1answer

I have a Woods upright freezer model #V17MUA. the date says 9701, would that mean January 1997?

Could be. Check with Woods to confirm.
12/9/2020 9:05:58 PM • Woods Freezers • Answered on Dec 09, 2020
0helpful
1answer

What is an equivalent to the Woods Freezer F20HDA? I need a new gasket. Measures 32X60

Terry Jul 05, 2020

You might try contacting the vendor's web site for wherever it was purchased. Similar Woods Freezer model parts are available of the searspartsdirect.com web site for a different model: https://www.searspartsdirect.com/model/o...

12/1/2020 11:30:44 AM • Woods Freezers • Answered on Dec 01, 2020
0helpful
2answers

Signicant ice build up in lower part of my Woods upright frost free freezer, model V470-YWZY30. Door seal is leaky (fails paper test). Would this account for significant build up? Thanks

Unplug the drain tube by shooting hot water down it with a turkey baster. It is located underneath the evaporator.
11/22/2020 6:07:43 AM • Woods Freezers • Answered on Nov 22, 2020
0helpful
1answer

Can't find the drip pan for Woods upright freezer

https://www.searspartsdirect.com/manual/383uw3lzpd-003083/wc-wood-v12naa-upright-freezer Page 6. Note the arrow in the drawing I suspect you want to unplug a clogged freezer drain. There are a number of youtube videos and web pages describing methods for you to consider if you google such. As I don't know the model of your freezer, I can't point to a specific remedy. I include one webpage as an example of a procedure. The page below simply describes pan locations. https://homeguides.sfgate.com/drip-pan-refrigerator-27482.html https://www.youtube.com/watch?v=H_DKNtgd5vI The company went into liquidation in 2009. There is an Ohio phone number but I am unable to find an active webpage for support. (419) 523-9663 Parts appear available from Sears Direct. Here is access to manuals for a number of models. https://all-guidesbox.com/model/wc-wood/c1517w3.html
10/17/2020 5:10:57 PM • Woods Freezers • Answered on Oct 17, 2020
0helpful
1answer

I need a controller( thermostat) for a Woods V12wau freestanding upright freezer

I would call the SearPartDirect unit, supply the model and serial number, and request the thermostat. I can't find your specific model via a search on their page but they may have the part anyway used in another model. https://www.searspartsdirect.com/combo/3083-1234585/wc-wood-freestanding-freezer-parts Alternatively, you might call the repairclinic number. https://www.repairclinic.com/Shop-For-Parts?query=woods%20V12wau%20thermostat%20for%20upright%20freezer
9/28/2020 8:42:14 AM • Woods Freezers • Answered on Sep 28, 2020
0helpful
2answers

What does the igloo and snowflake mean on the

igloo is cold snowflake is warmer.
8/14/2020 1:36:33 AM • Woods 201 cu.... • Answered on Aug 14, 2020
0helpful
1answer

Looking for parts manual for wc05zA-e

If anyone searching the internet sees this postings, possibly contact Sears: https://www.searspartsdirect.com/combo/3083-1234585/wc-wood-freestanding-freezer-parts
7/5/2020 4:22:41 PM • Woods Freezers • Answered on Jul 05, 2020
0helpful
1answer

Is it possible to find a manual on line for an upright freezer Woods model# BED 15Z

(GOOGLE) woods freezer/ model #BED15z /repair manual
5/7/2019 4:26:19 PM • Woods Freezers • Answered on May 07, 2019
0helpful
1answer

Woods upright freezer too cold?

A freezer temperature should be set a 0 F or -18 C
4/6/2019 12:15:20 AM • Woods Freezers • Answered on Apr 06, 2019
0helpful
1answer

I need a rebuild manual for a Woods Upright freezer model# wc05zae

I have been doing refrigeration work for over 30 years and have never heard of a "rebuild manual" for any unit ever build by any manufacturer. Try to phrase your question with specifically what you want to do and include the serial number as this may also help you cause. Good luck and hope this is of some help.
8/13/2018 2:02:45 AM • Woods Freezers • Answered on Aug 13, 2018
0helpful
1answer

The light on my chest

Both light flickering probably indicates a problem with the plug or the cord. If it was just the inside light I would suspect the door switch, but both light would indicates an open short in the wires or plug. Check the plug connection at the wall and see if it is loose. While unplugged check the cord for any nicks or cuts. Plug something else into the same wall receptacle , like a light and see if the power to the receptacle is ok. If none of the above work then it is time for a qualified repair person. J
2/20/2018 12:55:33 AM • Woods Chest... • Answered on Feb 20, 2018
0helpful
2answers

Just bought a Woods Upright freezer, not sure when it was last used, but when I got it home, i turned the knob to the cooldest setting (7) and it kiced on. how long should it take to start freezing. I

Freezer should not take more than 2 hours to.be at minus 10celcius. If only cold and not seeing any ice on the inside wall this could mean that there is missing refrigerant in the lines. Other way to check is to feel the pipes on the back if hot to the touch. There is many signs to see if your refrigerator is working or not.
If the compressor is running non stop and is very hot it will tell you that there is missing gas in the system.
If compressor is mot warm and is cycling on and off this could be only thermostat issue.

Good luck
12/29/2017 2:21:30 PM • Woods Upright... • Answered on Dec 29, 2017
Not finding what you are looking for?
Woods Logo

233 questions posted

Ask a Question

Usually answered in minutes!

Top Woods Freezers Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Brad Brown

Level 3 Expert

19187 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66835 Answers

Are you a Woods Freezer Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...