Precor Exercise & Fitness - Recent Questions, Troubleshooting & Support


FIXYA DOES NOT SELL ANY PRODUCTS OR PARTS FOR ANY

Precor Exercise... | Answered on Jan 19, 2020


Contact Precor directly to inquire.

Precor Exercise... | Answered on Oct 28, 2019


Precor Error 30, 31, 32 and 33, Communications Error Probable Cause 1. Bad interconnect cable between upper PCA and lower PCA.
2. Interconnect cable is mistakenly plugged into the CSAFE connector at the upper PCA.
3. Elliptical 5.17 equipped with old software version 1.01 in upper and lower PCA.
4. Upper and lower PCAs have mismatched software.
5. Another component plugged onto the PCA is overloading the +5VDC power supply.
6. Bad lower PCA.
7. Bad upper PCA.
Corrective Action
  1. Test unit with a know good interconnect cable or test the interconnect cable for continuity. Replace interconnect cable if necessary.
  2. Disconnect the interconnect cable from the CSAFE connector and attach to the proper position on the upper PCA.3.
  3. Replace the upper and lower software of the 5.17 elliptical with the most current versions.4.
  4. If one of the PCAs is found to have software version 1.01, replace it with the most current software version.
  5. Disconnect all components from the upper and lower PCA leaving the data cable connecting between the upper and lower PCAs and the AC power going to the lower PCA. If the unit shows any error other than the error 3x, reconnect components one at a time. Reset power between each newly connected component until the error 3x reappears. Whichever component was last connected when the error 3x reappears, is the cause for the error. Replace the faulty component.
  6. Test unit with a known good lower PCA. Replace the lower PCA if necessary.
  7. Test unit with a known good upper PCA. Replace the upper PCA if necessary.
Precor Error Code 30 31 32 33

Precor Premium... | Answered on Sep 13, 2019


Someone needs to look at this as noise issues can be from anywhere and anything.

877-805-1030
Book An appointment

Precor EFX 546i... | Answered on Apr 08, 2019


Are you sure the PSU is functioning? Check it with a multimeter set for DC Voltage. Compare what it is putting out to what the factory specs are.

Precor Exercise... | Answered on Mar 23, 2019

Not finding what you are looking for?
Precor Logo

923 questions posted

Ask a Question

Usually answered in minutes!

Top Precor Exercise & Fitness Experts

Ross Metcalfe
Ross Metcalfe

Level 2 Expert

135 Answers

The Knight
The Knight

Level 3 Expert

76204 Answers

ray gallant

Level 3 Expert

66233 Answers

Are you a Precor Exercise and Fitnes Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...