Gould pump BGR75 not pumping water

Question edited for clarity, 'Hmms' to 'hums'. Question moved from Cars and Trucks category. If it hums, it means the start/run capacitor on the motor has failed and needs replacing. https://www.google.com/search?q=GOULD+BGR75+humms ..
2/7/2023 5:30:09 PM • Goulds Pumps... • Answered on Feb 07, 2023
0helpful
1answer

Goulds j5s pump discharging rusty water and green moss particles. how do i flush

If its discharging all the time, I would say its sucking up contaminated water but if only occasionally, that would suggest something is rusting / deteriorating in the system and it "grows" when the pump is not in use. I would have a close look at the source tank(s), the connecting pipework and as a last resort, disconnect the pump and have a look inside the pump chamber.
12/7/2022 9:04:16 AM • Goulds Pumps... • Answered on Dec 07, 2022
0helpful
1answer

Goulds GT07 Irri-Gator Centrifugal Pump. It is a brand new pump is leaking.

Question edited for clarity. Question moved from Cars and Trucks to a Goulds category. Contact the maker of the supplier. It sounds like they left out a gasket or seal. https://www.google.com/search?q=Goulds+GT07+pump+leaking+water ..
4/1/2022 9:56:46 PM • Goulds Pumps... • Answered on Apr 01, 2022
0helpful
1answer

How do i remove impeller

Once you take off the front cover. You will see the impeller. Take of the rear cover and the shaft has a flat spot on it. You can hold it with a open ended wrench and spin off the impeller. It will be tight. There is no need to take it off unless it's broken.
3/15/2022 1:32:37 AM • Goulds Pumps... • Answered on Mar 15, 2022
0helpful
1answer
0helpful
1answer

Pressure switch clicks off and on will not stop

could be several things that cause this. I would first try increasing the spread between the upper and lower limits. it they are set too close together you can get this kind of bouncing on and off. Also, how old is the switch? as they age they get less and less accurate at reading the pressure accurately and this could be the problem. Longer shot, could be a leak in the well check valve. Water leaking back down into the well and that keeps turning the pump back on when there are no faucets open. If you need further help, reach me via phone at https://www.6ya.com/expert/marc_162a3912222e83a4
1/8/2016 7:14:10 PM • Goulds Pumps... • Answered on Jan 08, 2016
0helpful
1answer

When H2O runs pump keeps cycling every 15 to 20 sec. H2O drops to 30psi and pump stays on until 60psi. Then a couple of seconds does again until H2O is shut off. Pump runs for around 30 seconds.

If you've got the water turned all the way on, it sounds like your setup is operating normal. If the pump where turning of and on say every 5 seconds or so I would say to check the air pressure in the water holding tank that it's at the correct pressure.
3/18/2015 9:16:58 AM • Goulds Pumps... • Answered on Mar 18, 2015
0helpful
1answer

Dissemble pump motor from impeller

The impellers screw on. Hold motor shaft and unscrew.
11/26/2014 10:09:21 PM • Goulds Pumps... • Answered on Nov 26, 2014
0helpful
1answer

Wire diagram 4 gould gt20

Wiring diagrams for pump motors are usually on the inside of the cover of the wire access cover or on the motor tag. If this is a 1/2 HP motor it could possibly be wired 125V or 250V. Be sure to wire for correct voltage.
11/8/2014 10:15:22 PM • Goulds Pumps... • Answered on Nov 08, 2014
0helpful
1answer

The pressure is low on my home water pumping system.

Have you checked the pump intake for any blockage?
11/5/2014 8:06:42 AM • Goulds Pumps... • Answered on Nov 05, 2014
0helpful
1answer

With no water on at all my pressure tank kicks on about every three min.runs for twenty sec. then shuts off.

Hi David, The first thing I would check would be water level in all the toilet tanks on this system. If the level is too high in any one of them you may be getting a very slight amount of water overflowing into your toilet which could cause the pump to kick in as described. If the water level is clearly below the the top of the overflow tube. If that is not the problem I would then check to see that you have the correct adjustment on the high/low pessure setting screws. It is important that there is sufficent pressure differences between the two or it will behave as described. Another possibility is the air pressure level in your pressure tank. Make sure it has adequate pressure as per manufacturers instructions. Finally if none of the above were the problem I would invest in a LINEAR one way valve (about $25.00) and install that between the pump and your pressure tank. If your problem is still un-resolved then you do have a leak somewhere and will have to track it down... hot water tank, dish washer, clothes washer.... Good Luck Alan
11/5/2014 7:02:09 AM • Goulds Pumps... • Answered on Nov 05, 2014
0helpful
1answer

How to fix double starts from points kicking the breaker

If the breaker is tripping you need an electrician to check wiring, pressure switch shouldn't be a problem. Don't try to work your way around electrical, always remember the unit will last longer if electrical is running properly to unit.
9/1/2014 8:36:11 PM • Goulds Pumps... • Answered on Sep 01, 2014
0helpful
1answer

Gould water pump water pump will not shut off

Does the switch click open, if so it is wired wrong. If not it is set to high.
6/18/2014 5:09:30 PM • Goulds Pumps... • Answered on Jun 18, 2014
0helpful
1answer

Pump has not pressure and will not restart automatically

It may be the back flow check valve. If that valve is bad water will recirculate and never build pressure. If that is OK power it down then power back up. If it does not start then the controller is probably bad.
6/17/2014 8:44:43 PM • Goulds Pumps... • Answered on Jun 17, 2014
0helpful
1answer

Our goulds pumps j5s is running very loud after we replaced our sewage ejection pump last week. Could these problems be connected?

Those pumps last a long time. I do not think the problems are connected. I am assuming you are pumping water up from the pump. The pump has a check valve in the discharge that may not be closing. Cleaning that should solve your problem. Be sure water will pass through the discharge line into the drain.
6/13/2014 6:54:27 PM • Goulds Pumps... • Answered on Jun 13, 2014
Not finding what you are looking for?
Goulds Pumps Logo

22 questions posted

Ask a Question

Usually answered in minutes!

Top Goulds Pumps Plumbing Experts

john h

Level 3 Expert

29494 Answers

Brad Brown

Level 3 Expert

19187 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66949 Answers

Are you a Goulds Pumps Plumbing Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...