0helpful
1answer

Under-microwave/over the stove bulbs keep burning out

It should be an "appliance" type bulb. They are made to handle vibrations associated with fans and/or motors.
10/31/2023 6:44:14 PM • Electrical... • Answered on Oct 31, 2023
0helpful
1answer

Fuji Micro XG-SF3700 generator. I need a flywheel for it please?

Question edited for clarity.There are some parts suppliers in the link, but likely to be a special order from China.https://www.google.com/search?q=Fuji+Micro+XG+SF3700+generator+parts..
10/30/2023 8:10:58 PM • Electrical... • Answered on Oct 30, 2023
0helpful
1answer

Steele Products GG-600N 6000 peak Watts Portable Generator. Can it be converted to electric start?

Question edited for a lot more clarity. There is a video that might help, but there is no conversion kit. What some people do it remove the recoil start and use an impact driver or electric drill with a socket that fits the bolt on the end of the crankshaft. https://www.google.com/search?q=Steele+GG600N+generator+convert+to+electric+start
10/29/2023 10:53:06 PM • Electric... • Answered on Oct 29, 2023
0helpful
1answer

How to open the Hubbell YQ230 in order to test line voltage.

Turn off the power source to the device you want to test. Unplug the adapter from the power source. Locate the two screws on the adapter's faceplate. Use a screwdriver to remove the screws. Gently pull apart the two halves of the adapter. Once you have opened the adapter, you can use a voltage indicator to test the line voltage . If you don't have one, you can purchase it from Hubbell's website or any other electrical equipment supplier. The MarineEngine.com website states that the Hubbell YQ230 adapter has a UV-resistant housing and two screws on its faceplate. You can use a screwdriver to remove these screws and open the adapter.
10/27/2023 6:10:03 AM • Electrical... • Answered on Oct 27, 2023
0helpful
1answer

Is there a operation manual for Miller and falls ATS

This manual is all I could find. Instructions and Parts List for Setting Up and Operating Millers Falls Langdon Acme Mitre Box, Langdon Mitre Box : Form No. M709 : Millers Falls Co. : Free Download, Borrow, and Streaming : Internet Archive I also found a few results on the web for "miller and falls generator automatic transfer switch". One of the results is a 240V Automatic Transfer Switch by Millers Falls that can be used with GSD7500 & GSD9000 Series Diesel Generators . This switch can be wired directly to the house or workshop mains power fuse box. In Automatic mode, the switch will automatically start the generator if mains power fails for whatever reason. Once the generator is up to full speed and generating voltage at 50Hz, the switch will feed the power into the required load point. When mains power is restored, the ATS will transfer load from the generator back to mains power then shut down the generator. This same function can also be performed in manual mode if required. The wiring of the ATS must only be performed by a licensed electrician. The solenoid operating mechanism of the ATS ensures a high-speed transfer of loads between alternate sources of power, regardless of current draw. These ATS transfer boxes are available in 3 models to suit Millers Falls GSD7500 & GSD9000 (silenced & open frame) diesel generators, GSD13000 diesel generators (silenced & open frame), GSC12000i-Y & GST11000A petrol generators
10/26/2023 1:42:37 PM • Miller... • Answered on Oct 26, 2023
0helpful
1answer

No power at outlets

I have a DeWalt dg 6000 and it does not have electricity coming out of the generator to the plug out lit so what do you think about the power not working
10/25/2023 10:03:32 PM • Dewalt DG6000... • Answered on Oct 25, 2023
0helpful
1answer

Generator will start but won't rev up

What's the make/model? Many don't rev up until they're under load.
10/25/2023 5:27:08 PM • Electrical... • Answered on Oct 25, 2023
1helpful
1answer

Free manual 7000/8750 black max manual

Need parts for maintnance
10/22/2023 2:55:18 PM • Honda Black Max... • Answered on Oct 22, 2023
0helpful
2answers

Difference between Intermatic Timers R8806R101C and R8806P101C please?

question edited for clarity, 'make model (what it is)'. The Google 'versus' trick is useful in question like this. https://www.google.com/search?q=R8806R101C+vs+R8806P101C ..
10/22/2023 2:44:00 AM • Electrical... • Answered on Oct 22, 2023
0helpful
2answers

2006 Miller Trailblazer Pro 350d wont weld or generate power , in startup it will jump to 80volts then immediately drop to 0 , if it's the voltage regulator where is it located on the machine? Thanks

See attachment, item 9.

Go to

https://www.millerwelds.com/support/manuals-and-parts.

Enter Model/SN and download owners manual. Diagrams and parts lists are in the manual.

Check all fuses with an ohm meter for continuity.
10_16_2023_9_39_02_pm.jpg
10/19/2023 1:45:06 PM • Miller... • Answered on Oct 19, 2023
0helpful
1answer

Can this controller be replaced with a controller thats not nema 4

Whether or not a NEMA 4 controller can be replaced with a controller that is not NEMA 4 depends on the specific application. NEMA 4 controllers are designed to withstand water and dust ingress, so they are often used in outdoor or harsh environments. If the controller is being used in an environment where it is exposed to water or dust, then it is important to replace it with a NEMA 4 controller. Overall, it is important to consult with a qualified electrician before replacing a NEMA 4 controller with a controller that is not NEMA 4. The electrician can assess the specific application and recommend the best controller for the job. If you want to look for a controller, you can visit: https://www.chipsmall.com/bigcategory/industrial-automation-and-controls.html to search for the controller you want.
10/18/2023 6:58:42 AM • Electrical... • Answered on Oct 18, 2023
0helpful
2answers

My husky 3750 generator will start but it will not produce any power. I plug a radio into it and it won't power it up. What's wrong?

Troubleshooting and videos

What causes no electrical output in Husky generator?

JustAnswer https://www.justanswer.com > small-engine > 4e3fa-hu... Dec 29, 2010 - Let me know what you find, and we will continue of if need be - but the single most common issue with these sets, by far, is a bad voltage ... 1 answer · Top answer: Ok, here is what you need to do next. Please read these instructions carefully, and do the ...

Husky Generator won't start

Repair Clinic https://www.repairclinic.com > RepairHelp > Husky-G... Here are the most common reasons your Husky generator's engine won't start - and the parts & instructions to fix the problem yourself.

Fixing Portable Generators - No Power

Aurora Generators https://www.auroragenerators.com > post > fixing-portab... Mar 1, 2022 - The most common cause of portable generators failing to produce electricity is from the loss of residual magnetism.
10/18/2023 2:52:18 AM • Husky Electrical... • Answered on Oct 18, 2023
0helpful
2answers

What is the colored wire positions on a craftsman 2400 mower key switch

See following URL for complete wiring diagram.https://www.searspartsdirect.com/model/3x23oa7iyt-000247/craftsman-917203831-front-engine-lawn-tractor-partsSwitch Terminal to circuit color.B RedS WhiteM Black (Black/white)A1 BlueA2 BlackL BlackG BlackUnfortunately 4 of the circuits are not uniquely color coded. If the black wires have been disconnected from the switch socket then it will be necessary to identify each black wire to its respective circuit.9_28_2023_9_24_45_pm.jpg9_28_2023_9_24_46_pm.jpg
10/13/2023 5:49:31 AM • Craftsman... • Answered on Oct 13, 2023
0helpful
3answers

I have a generac ix

You engine has a low oil level sensor. If the oil level is low or..... the sensor is bad it will ground the ignition from the coil with the engine switch on. For troubleshooing only disconnect ONE wire from the sensor AFTER you make sure the engine oil level is properly serviced. Then check for spark.

If this does not correct the problem just respond and I will help you.

Thanks for choosing FixYa,
Kelly
10/12/2023 6:11:17 PM • Generac Power... • Answered on Oct 12, 2023
0helpful
1answer

Miller Trailblazer 325 (Kohler) Trailblazer welder/generator. It has an idle problem. The machine running only on high RPM. Not going back to idle. Any idea why?

Question edited for clarity. Question moved to a better category. You model says it has electronic speed control and needs setting by a dealer. This model shows adjustment. If it has a carburetor, you should be able to adjust idle speed. https://www.manualslib.com/manual/1163862/Miller-Trailblazer-275-Dc.html?page=48 https://www.google.com/search?q=miller+trailblazer+325+engine+speed+adjustment ..
10/4/2023 4:08:53 AM • Miller... • Answered on Oct 04, 2023
0helpful
1answer

Wacker Neuson DPU 5545 Vibratory Plate. I turn the key, it beeps but it won't turn over. What do I need to check?

Question edited for clarity, 'Nelson' to Neuson, and 'DPU' to BPU. Question moved from Cars and Trucks to make model category. Having read the manual, it sounds like the 'Oil Alert System' on Page 31. https://www.rentalex.com/wp-content/uploads/2017/04/BPU4045A_Operators_Manual.pdf ..
9/27/2023 1:45:28 AM • Wacker Neuson... • Answered on Sep 27, 2023
0helpful
1answer

Generac Standby Generator. I have a red blinking light on on the OFF button on the Guardian 2.0 control panel?

Question edited for a lot more clarity. Model and KVA helps. Question moved from Televisions to Generac Guardian category. Information to troubleshoot in the link and video. https://www.google.com/search?q=generac+guardian+standby+generator+switch+off+led+flashing+red ..
9/22/2023 4:10:31 PM • Generac... • Answered on Sep 22, 2023
0helpful
1answer

When I pull start my sportsman 7 hp generator it stops like the piston is stuck but when I remove the spark plug it turns right over

Hopefully you have the correct reach spark plug. Too long and it will jam up the piston.
9/16/2023 6:34:41 PM • HP Electrical... • Answered on Sep 16, 2023
1helpful
1answer
Not finding what you are looking for?
Electrical Supplies Logo

22,728 questions posted

Ask a Question

Usually answered in minutes!

Top Electrical Supplies Experts

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66931 Answers

Are you an Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...