Question about 72 cu. ft. / 2039 liter Commercial Freezer T-72F
I NEED A DIAGRAM FOR DEFROST SWITCH ON T-72 F TRUE FREEZER defrost switch is got 2 black wires and 1 red wire Go to www.truemfg.com and it will take you to their web site. They have a 24 hour, ask a ...
Question about TD-65-24 Commercial Refrigerator
will not cool down could it be the cap tube tru td-65-24 hear the fan come on but will not cool Im working on a TRUE beer cooler m/n AEA4440YXA & it will not cool down below 50 degrees. I have ...
Tru GDM-47 cooler and the evaporator keeps icing up in back due to the compressor not cycling. It has a brand new compressor and if we turn the thermostat down, we can get the cooler to go down to the
I have a TRU GDM-23F display freezer. The defrost timer quit, so I'm replacing it with a Paragon 8143 which is what came out of it. The new timer came with a warning to check for feedback voltage ...
where is the thermastat on the tru slider door our pop is freezing on the left side Most are on the top right side of the evaporator(cooling) coil inside the box.
freeon leak Is there a tech that can repair a leak in the lines? Recently a tech injected a stop leak into the system and it only lasted about two months. there is no such thing as a stop leak , he my
Tru mug chiller won't get cold The mug chiller won't get cold Is the compressor running? Is the condenser clean and the fan running? Is the fan inside running? Is there ice on the coil? Those are the ...
Question about Refrigerated Sandwich Prep Table 72" 30 Pan
Need door gasket for Jimex cold tech model S1BRR-06S Need door gasket Cold Tech gaskets can be obtained from Case Parts Co. 800-421-0217 or RHS Parts 800-537-8300, per jimex corps final technical spec
Question about Refrigerated Sandwich Prep Table 72" 30 Pan
I have a true tdd-3 that will not get below 41 deg. Also water is accumulting were the kegs sit. I can here the compressor running. We have the temp turned down. The fins are cleanclear of any debris.
Question about Refrigerated Sandwich Prep Table 72" 30 Pan
True T-49F 55? 2 Door Solid Reach In Freezer. How to solve error code E1 on freezer Tru T49f? Question edited for clarity. Question moved to maker category. Thermostat Probe Error E1 error on a true ...
Usually answered in minutes!
39 Questions
34 Questions
27 Questions