...treadmill go. What does this codde mean? Error 22 - No Motor Pulses at Start Up Description Error 22 indicates that the drive motor (running belt) has been instructed to start, by either manual or ...
...treadmill and on another err45 ..... Any answers? Plus some treadmills same to just trip, have to keep switch them back on! Error 22 indicates that the drive motor (running belt) has been instructed ...
...treadmill speed or initiate an error code sequence, if necessary. Typically, if a problem exists with the speed sensor the drive motor will operate (perhaps only briefly) before a speed related error ...
Question about 956i Experience Series Treadmill (Used)
...Error Probable Cause 1. Bad interconnect cable between upper PCA and lower PCA. 2. Interconnect cable is mistakenly plugged into the CSAFE connector at the upper PCA. 3. Elliptical 5.17 equipped with ...
error 32 Turn on treadmill, 10 seconds later error 32 scrolls across screen DescriptionErrors 30 through 33 all indicate the loss of communications or erratic communications betweenthe microprocessors
...treadmill error L5 Precor Error LS, Speed Sensor Signal Missing Probable Cause 1. Intermittent or open connection of the speed sensor (reed switch) wiring. 2. Reed switch is defective or has ...
Question about C966i Treadmill C 966i
...Error log is empty. Unit simply turns off at random. I Scrolled the speed upto 16 mph to test to see if a thermal switch was bad but it wouldn't trip even after 10 minutes of operation at ...
...error 22 flashes up reset the machine make this: God bless you Unplug the treadmill. Locate the console key and place the safety or reset key into the treadmill console. Replace any parts that need ...
...Error LS, Speed Sensor Signal Missing Probable Cause 1. Intermittent or open connection of the speed sensor (reed switch) wiring. 2. Reed switch is defective or has intermittent connection. 3. Drive ...
Question about Premium Series 9.31 Treadmill
...treadmill? Precor Error 30, 31, 32 and 33, Communications Error Probable Cause 1. Bad interconnect cable between upper PCA and lower PCA. 2. Interconnect cable is mistakenly plugged into the CSAFE ...