Question about Powermate Premium Plus 6250W Portable Generator
i cant remember which wire goes where on the on/off switch switch has three leads, i have three wires. which goes where? please supply me with a photo of the switch and where those wires are coming ...
Question about Propane Forced Air Heater w/Electronic Ignition (50,000-80,000 BTU)
...in a trailer and was trying to turn on my heater and when I flipped the switch the light blinks three times which it says means that the combustion air switch failed to close.... how do I fix
Question about Propane Forced Air Heater w/Electronic Ignition (50,000-80,000 BTU)
...heater is cycling acording to the thrmastat but wont heat up. The trouble shooting light flashes three times.What part do you think is failing? 3 flashes is the combustion pressure switch .
Question about Propane Forced Air Heater w/Electronic Ignition (50,000-80,000 BTU)
...three times. It represents ignition lockout. How do I fix it Pressure switch error code, check air filter, condenstate drain and hoses, check for vent blockage, check for low spots in the venting ...
Question about Powermate Premium Plus 6250W Portable Generator
...back side gently squeeze the clips holding the switch and firmly push the switch out. Wire tie the three wires to the same length and place the tie about 3 inches back from the connectors. Trim the ...
Question about Propane Forced Air Heater w/Electronic Ignition (50,000-80,000 BTU)
...as necessary. Also make sure there are no blockages in your exhaust pipe. If, after doing these three items, you continue to have a problem, let us know and we'll dig a little deeper. But 99% of ...
Question about Propane Forced Air Heater w/Electronic Ignition (50,000-80,000 BTU)
coleman furnace(propane) will not start and I get a code three(combustion air switch failed to close. any quick fix change presure switch , no quick fix
Question about Propane Forced Air Heater w/Electronic Ignition (50,000-80,000 BTU)
...before we need it for the winter; the following condition occurred. Condition: Flashing code of three (red light) flashes (Combustion air switch failed to close) fault code. Replaced and/or ...
Question about 7990-319p Evcon Gas Furnace Control Board
...i do now? air combustion switch was replaced but didn't solve issue indicator light still flashes three times There should be a diagnostic chart on the furnace door by the wiring schematic. If so ...
Question about 7990-319p Evcon Gas Furnace Control Board
...switch error on windy days Coleman furnace about 15 years old. The light flashes twice or three times and furnace will not run. Blowing in the tubing and resetting the furnace makes it work ...
Usually answered in minutes!
549 Questions
64 Questions
57 Questions
47 Questions