Questions & Answers for: sta rite heater error

Question about Sta-Rite Max-E-Therm High Effiency - Propane Heater - 333,000 BTU

2 Answers

Sta-Rite SR400 heater displays error E01 and doesn't fire. Momentarily displays r 3 before going to E01. Resolved - the thermister was bad. Replace the thermistor. The average price is around $44.00

Ad

Question about Sta-Rite Max-E-Therm High Effiency - Propane Heater - 333,000 BTU

1 Answer

sta rite 400na gives error code 05 after about 30 seconds max-e-therm sta-rite pool heater works for 30 seconds or so, then heat shuts off and error code o5 with service heater light comes on. ...

Ad

Question about STA-RITE CONTROL BOARD KIT - 42001-0096S

1 Answer

Sta-Rite Problem; Error codes R8, Won't stay on. Turn on heater, reads 160 then says R8, then power turn off completely. Replaced control board and I get the same error. Please help so I don't have to

Question about Sr400na Max E Therm Pool & Spa Heater Dual Electronic Ignition Lo Nox 400,000 Btu Natural Gas

1 Answer

...sta-rite shows r 5 code when power is turned on. sta-rite pool heater sr400na. The R5 is a sequence code in the boot up sequence where your error is occuring. There is nothing in the users manual for ...

Question about STA-RITE CONTROL BOARD KIT - 42001-0096S

0 Answer

Sta-Rite Pool heater does not fire up. Error E01 displayed. I have a Sta-Rite pool heater Model SR400LP with an error code of E01. Does anyone know what this code is indicating? Heater does not fire ...

Question about Sta-Rite Max-E-Therm High Effiency - Propane Heater - 333,000 BTU

1 Answer

I have a e05 error code. My sr400na Sta-rite pool heater runs for 1 minute and then shuts down. Help thanks Paul Harris check the sensor that is on the exaust

Question about Sta-Rite Max-E-Therm High Effiency - Propane Heater - 333,000 BTU

0 Answer

Sta-rite max-e-therm 400 propane heater, gives error code E01 and it wont start. possible bad ignitor

Question about Sta-Rite Max-E-Therm High Effiency - Propane Heater - 333,000 BTU

0 Answer

sta-rite sr200LP 180 r9 error I have a STA-Rite hot tub heater and when I turn on power the display lashes 888 then 180 then r9 then goes dead. I cannot get any after that to happen unless I turn of ...

Question about Sta-Rite Max-E-Therm High Effiency - Propane Heater - 333,000 BTU

1 Answer

how to fix error code 6 on a sta-rite pool heater? Try replacing the Temp sensor. You can not just jump it out, it needs to be repaced.

i changed Stack Flue Sensor in my Sta-Rite pool heater, but still gives me an error 05? What should I do next? check the thermal regulator and internal bypass, and the heat exchanger

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Pool & Spa Experts

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

john h

Level 3 Expert

29494 Answers

David Spradling
David Spradling

Level 3 Expert

13520 Answers

Are you a Pool & Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...